• Title/Summary/Keyword: Operational Temperature

Search Result 592, Processing Time 0.029 seconds

Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

Thermal Compensation Circuit with Improved Compensation Characteristic for Power Amplifier (개선된 보상특성을 갖는 증폭기용 온도보상회로)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.177-181
    • /
    • 2012
  • This paper introduces a thermal compensation circuit with improved compensation characteristic for amplifiers to provide stable output power regardless environmental temperature. The proposed thermal compensation circuit is composed of two branchline couplers having two diodes between them. And, the thermistor whose resistance varies significantly with temperature inversely and a operational amplifiers, so called as OP-amp, control the diodes in the compensations circuit to realize more effective thermal compendation characteristic compared with conventional circuit.

The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System (냉방시스템의 운전조건에 따른 에너지 소비특성 연구)

  • Park, Gi-Tae;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

Shrinkage of Injection Molded Part for Inorganic Additive Compositions (무기 첨가물 함량에 따른 사출성형품의 성형 수축)

  • Kim B.D.;Yoo Y.H.;Hwang B.H.;Lyu M.Y.;Kim A.S.;Park S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.58-64
    • /
    • 2004
  • The shrinkages of injection molded parts are different in molding operational conditions, resins and additives. The shrinkage of injection molded part for crystalline polymer, PBT (polybutylene terephthalate) has been studied for various operational conditions of injection molding and content of additives. Mica was used as a additive to PBT to examine the part shrinkage according to the mica content. The part shrinkages of mica contained PBT decreased as mica content increases. Higher injection temperature and injection pressure resulted in a lower shrinkage. As mold temperature increases the part shrinkage decreased. The part shrinkage of flow direction was less than that of the perpendicular direction to the flow for both pure and mica contained PBT. However the shrinkage difference between flow and perpendicular to flow directions decreased as mica content increased.

  • PDF

Derivative Thermometric Titrations Employing Operational Amplifier Instrumentation (연산증폭기를 사용한 미분법 열적정장치)

  • Czae, Myung-Zoon;Pyun, Chong-Hong;Kim, Sang-Ok
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.341-345
    • /
    • 1970
  • An improved derivative thermometric titration apparatus designed around operational amplifiers is described which is capable of monitoring the small temperature change and of computing the derivatives for accentuation of the titration end point that is difficult to locate by extrapolation methods. The instrument is constructed of four commercial operational amplifiers. A use of dummy cell provides the subtraction means for compensation of the initial temperature and random temperature fluctuations with a resultant gain in signal-to-noise ratio. The successive differentiation action of the computer has been nearly "perfect," so that the two breaks (blank or starting and end point of the titration curve can be located with the precision of 0.2% by observing two peak points on the second derivative curve. Arrangements useful in obtaining such a good derivative response that is exactly proportional to the input signal are discussed. Plots of the enthalphogram and its derivatives are presented, with the results of several titrations used to evaluate the performance of the apparatus.

  • PDF

Study on the cantilever ratio optimization of high-temperature molten salt pump for molten salt reactor based on structural integrity

  • Xing-Chao Shen;Yuan Fu;Jian-Yu Zhang;Jin Yang;Zhi-Jun Li
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3730-3739
    • /
    • 2024
  • The high-temperature molten salt pump is the core equipment in the small modular molten salt reactor with media temperatures up to 700 ℃. The cantilever ratio of the molten salt pump is usually large. Excessively large cantilever ratios cause increased deformations and rotational amplitudes at the impeller, thus affecting the operational stability of the main pump; small cantilever ratios cause heavy temperature gradients, thus affecting the structural integrity evaluation. This paper used numerical simulation methods to calculate and analyze the temperature field, stress, and structural integrity, optimized the pump shaft cantilever length of the original scheme based on structural integrity using the dichotomy method, and analyzed the rotor dynamics of the optimization results. The results of this study show that the thermal expansion load caused by the temperature difference has a significant mechanical effect on the structure; the first-order critical speed of the rotor system of the optimized schemes has been improved, and the amplitude of the unbalanced response has been significantly reduced, which not only improves the operational stability of the rotor, also contributes to the compact design of the main pump of a small modular molten salt reactor.

Verification of the KMA Ocean Model NEMO against Argo Floats and Drift Buoys: a Comparison with the Up-to-date US Navy HYCOM (Argo 플로트와 표류부이 관측자료를 활용한 기상청 전지구 해양모델 (NEMO)의 검증: 최신 미해군 해양모델(HYCOM)과 비교)

  • Hyun, Seung-Hwon;Hwang, Seung-On;Lee, Sang-Min;Choo, Sung-Ho
    • Atmosphere
    • /
    • v.32 no.1
    • /
    • pp.71-84
    • /
    • 2022
  • This paper describes verification results for the ocean analysis field produced by the Nucleus for European Modelling of the Ocean (NEMO) of the Korea Meteorological Administration (KMA) against observed Argo floats and drift buoys over the western Pacific Ocean and the equatorial Pacific during 2020~2021. This is confirmed by a comparison of the verification for the newly updated version of the HYbrid Coordinate Ocean Model/Navy Coupled Ocean Data Assimilation (HYCOM/NCODA) against same observations. NEMO shows that the vertical ocean temperature is much closer to the Argo floats than HYCOM for most seasons in terms of bias and root mean square error. On the other hand, there are overall considerable cold biases for HYCOM, which may be due to the more rapid decreasing temperature at the shallow thermocline in HYCOM. Conclusion demonstrated that the NEMO analysis for ocean temperature is more reliable than the analysis produced by the latest version of HYCOM as well as by the out-of-date HYCOM applied to the precedent study. The surface ocean current produced by NEMO also shows 14% closer to the AOML (Atlantic Oceanographic and Meteorological Laboratory) in situ drift buoys observations than HYCOM over the western Pacific Ocean. Over the equatorial Pacific, however, HYCOM shows slightly closer to AOML observation than NEMO in some seasons. Overall, this study suggests that the resulting information may be used to promote more use of NEMO analysis.

A Design of LC-tuned Sinusoidal VCOs Using OTA-C Active Inductors

  • Chung, Won-Sup;Son, Sang-Hee
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.122-128
    • /
    • 2007
  • Sinusoidal voltage-controlled oscillators (VCOs) based on Colpitts and Hartley oscillators are presented. They consist of a LC parallel-tuned circuit connected in a negative-feedback loop with an OTA-R amplifier and two diode limiters, where the inductor is simulated one realized with temperature-stable linear operational transconductance amplifiers (OTAs) and a grounded capacitor. Prototype VCOs are built with discrete components. The Colpitts VCO exhibits less than 1% nonlinearity in its current-to-frequency transfer characteristic from 4.2 to 21.7 MHz and ${\pm}$95 ppm/$^{\circ}C$ temperature drift of frequency over 0 to $70^{\circ}C$. The total harmonic distortion (THD) is as low as 2.92% with a peak-to-peak amplitude of 0.7 V for a frequency-tuning range of 10.8-32 MHz. The Hartley VCO has the temperature drift and THD of two times higher than those of the Colpitts VCO.

  • PDF

Analysis of Distribution Power System with Thermal Conductor Distribution Lines (내열 도체가 적용된 가공 배전선의 적용 영향에 관한 연구)

  • Kim, Myong-Hyon;Lee, Kyone-Tae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.243-244
    • /
    • 2015
  • Power system has been improved during for a long time by customers demand. Power suppliers has researched the power system component for more electricity transmission. One of the research is apply the thermal conductors in new cable. The operational temperature of thermal conductors is higher than normal aluminum that thermal conductor is composed of aluminum, Zr(zirconium) and etc. Increase of operational temperature is growth of the transmission capability. Power suppliers was concerned about the increase of operation temperature by thermal conductors. Therefore, the thermal conductor has the possibility that expanded application in power system. In this paper analysed effect of thermal conductor in power distribution system.

  • PDF