• Title/Summary/Keyword: Operation margin

Search Result 402, Processing Time 0.028 seconds

Changes in Performance and Operating Condition of a Gas Turbine Combined Heat and Power System by Steam Injection - A Focus on Compressor Operation (증기분사에 의한 가스터빈 열병합발전 시스템의 성능과 운전조건 변화 - 압축기 작동 변화를 중심으로)

  • Kang, Soo-Young;Kim, Tong-Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.68-75
    • /
    • 2011
  • This study simulated the effect of steam injection on the performance and operation of a gas turbine combined heat and power (CHP) system. A commercial simple cycle gas turbine was analyzed. A full off-design analysis was carried out to investigate the variations in not only engine performance but also the operating characteristics of the compressor caused by steam injection. Variation in engine performance and operation characteristics according to various operation modes were examined. First, the impact of full steam injection was investigated. Then, operations aiming to guarantee a minimum compressor surge margin, such as under-firing and partial steam injection, were investigated. The former and latter were turned out to be relatively superior to each other in terms of power and efficiency, respectively.

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

Development of a framework to estimate the sea margin of an LNGC considering the hydrodynamic characteristics and voyage

  • You, Youngjun;Choi, Jin Woo;Lee, Dong Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.184-198
    • /
    • 2020
  • Decisions of the design speed, MCR, and engine capacity have been empirically made by assuming the value termed the sea margin. Due to ambiguity regarding the effect of some factors on the sea margin, the value has been commonly decided based on experience. To evaluate the value from a new viewpoint, it is necessary to construct an approach to estimate the sea margin through an objective procedure based on a physical and mathematical model. In this paper, a framework to estimate the actual sea margin of an LNGC based on the maneuvering equations of motion is suggested by considering the hull, propeller, rudder, and given sea route under wind and waves. The fouling effect is additionally quantified as the increase of total resistance by considering the re-docking period. The operation data is reviewed to amend the increase of the total resistance considering the speed loss of a ship. Finally, the factor of how much the resistance increases due to fouling is newly obtained for the vessel. Based on the comparison of the estimated sea margin with the empirical range of the sea margin, the constructed framework is regarded as feasible.

High Speed TCAM Design using SRAM Cell Stability (SRAM 셀 안정성 분석을 이용한 고속 데이터 처리용 TCAM(Ternary Content Addressable Memory) 설계)

  • Ahn, Eun Hye;Choi, Jun Rim
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.19-23
    • /
    • 2013
  • This paper deals with the analysis of 6T SRAM cell stability for Hi-speed processing Ternary Content Addressable Memory. The higher the operation frequency, the smaller CMOS technology required in the designed TCAM because the purpose of TCAM is high-speed data processing. Decrease of Supply voltage is one cause of unstable TCAM operation. Thus, We should design TCAM through analysis of SRAM cell stability. In this paper we propose methodology to characterize the Static Noise Margin of 6T SRAM. All simulations of the TCAM have been carried out in 180nm CMOS process technology.

Two-Bit/Cell NFGM Devices for High-Density NOR Flash Memory

  • Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.1
    • /
    • pp.11-20
    • /
    • 2008
  • The structure of 2-bit/cell flash memory device was characterized for sub-50 nm non-volatile memory (NVM) technology. The memory cell has spacer-type storage nodes on both sidewalls in a recessed channel region, and is erased (or programmed) by using band-to-band tunneling hot-hole injection (or channel hot-electron injection). It was shown that counter channel doping near the bottom of the recessed channel is very important and can improve the $V_{th}$ margin for 2-bit/cell operation by ${\sim}2.5$ times. By controlling doping profiles of the channel doping and the counter channel doping in the recessed channel region, we could obtain the $V_{th}$ margin more than ${\sim}1.5V$. For a bit-programmed cell, reasonable bit-erasing characteristics were shown with the bias and stress pulse time condition for 2-bit/cell operation. The length effect of the spacer-type storage node is also characterized. Device which has the charge storage length of 40 nm shown better ${\Delta}V_{th}$ and $V_{th}$ margin for 2-bit/cell than those of the device with the length of 84 nm at a fixed recess depth of 100 nm. It was shown that peak of trapped charge density was observed near ${\sim}10nm$ below the source/drain junction.

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

Influence of Parasitic Resistances and Transistor Asymmetries on Read Operation of High-Resistor SRAM Cells (기생저항 및 트랜지스터 비대칭이 고저항 SRAM 셀의 읽기동작에 미치는 영향)

  • Choi, Jin-Young;Choi, Won-Sang
    • Journal of IKEEE
    • /
    • v.1 no.1 s.1
    • /
    • pp.11-18
    • /
    • 1997
  • By utilizing the technique to monitor the DC cell node voltages through circuit simulation, degradation of the static read operating margin In high load-resistor SRAM cell was examined, which is caused by parasitic resistances and transistor asymmetries in this cell structure. By selectively adding the parasitic resistances to an ideal cell, the influence of each parasitic resistance on the operating margin was examined, and then the cases with parasitic resistances in pairs were also examined. By selectively changing the channel width of cell transistors to generate cell asymmetry, the influence of cell asymmetry on the operating margin was also examined. Analyses on the operating margins were performed by comparing the supply voltage values at which two cell node voltages merge to a single value and the differences of cell node voltages at VDD=5V in the simulated node voltage characteristics. By determining the parasitic resistances and the transistor asymmetries which give the most serious effect on the static read-operation of SRAM cell from this analysis based on circuit simulated, a criteria was provided, which can be referred in the design of new SRAM cell structures.

  • PDF

Profitability determinants of hospitals (병원의 수익성 관련 요인)

  • 이윤석;유승흠
    • Health Policy and Management
    • /
    • v.13 no.3
    • /
    • pp.129-147
    • /
    • 2003
  • This study is to grasp a trend of profitability classified by characteristics of hospitals and to analyze related factors. Subjects are 145 hospitals which have gotten the standardization audit by Korean Hospital Association during 1998-200l. Profitability was measured in the aspect of operation profit rate with operating margin to gross revenue as proxy variables. Independent variables were classified by general factors (ownership, number of beds, period of establishment, competition), financial factors (liabilities to total assets, current ratio, fixed ratio, total asset turnover, inventories turnover), and factors related to patient treatment (average length of stay, bed occupancy rate, new outpatient ratio, admission ratio of outpatients, number of patients per specialist, personnel costs per adjusted inpatient, administrative costs per adjusted inpatient). Hierarchical multiple regression analysis model was used in this study. As a result of hierarchical multiple regression analyzation of operating margin to gross revenue, adjustive $R^2$ of general factors was relatively more powerful. The factors had significant effect on operating margin to gross revenue were ownership(+), number of beds(+), competition(+), current ratio(+), fixed ratio(+), total asset turnover(+), personnel costs per adjusted inpatient(-).

Design and Experimental Study on a Turbo Air Compressor for Fuel Cell Applications (연료전지용 터보 공기압축기의 설계 및 시험평가)

  • Choi, Jae-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.1
    • /
    • pp.26-34
    • /
    • 2008
  • This study presents an aerodynamic design and an experimental performance test of a turbo air compressor consisted of mixed-flow impeller and curved diffuser for the PEM fuel cell vehicle application. Many studies compare the efficiency, cost or noise level of high-pressure and low-pressure operation of PEM fuel cell systems. Pressure ratio 2.2:1 is considered as design target The goal of compressor design is to enlarge the flow margin of compressor from surge to choke mass flow rate to cover the operational envelope of FCV. Large-scale rig test is performed to evaluate the compressor performance and to compare the effects of compressor exit pipe volume to stall or surge characteristics. The results show that the mixed-flow compressor designed has large flow margin, and the flow margin of compressor configuration with small exit volume is larger than that with large exit volume.

OVERALL LINK ANALYSIS ON HRIT AND LRIT IN COMS

  • Park Durk-Jong;Hyun Dae-Wan;Kang Chi-Ho;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.98-100
    • /
    • 2005
  • This paper describes link analysis on the processed data, HRIT (High Rate Information Transmission) and LRIT (Low Rate Information Transmission), for the preliminary design of interface between COMS (Communication, Ocean and Meteorological Satellite) and ground station. At the MODAC (MeteorologicaVOcean Data Application Center), the processed data are transmitted to user station via COMS with normalization and calibration by pre-processing of MI (Meteorological Imager) data. Due to consider satellite as radio relay, overall analysis containing uplink and downlink is needed. Specific link parameters can be obtained with using the outcomes of SRR (System Requirement Review) which was held on 13-14 June 2005, in Toulouse. From the relation between overall link margin and output power of HPA (High Power Amplifier) of MODAC, it is shown that even though the minimum power related with COMS receiving power range is transmitted at MODAC, the obtained link margin of HRIT could be above 3 dB at user station which antenna elevation angle is 10 degree.

  • PDF