• Title/Summary/Keyword: Operating Tunnel

Search Result 223, Processing Time 0.036 seconds

A study on the fire smoke diffusion delay strategy in a great depth underground double deck tunnel junction (대심도 복층터널 교차로 화재연기 확산지연 방안 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek;Han, Jae-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.115-126
    • /
    • 2019
  • Recently, in order to solve the traffic congestion in urban areas and to improve the peripheral environment, research on the design and construction technology development of great depth underground double-deck tunnel is under way by using the underground space in the urban area. The network type double-deck tunnel is in the form of an intersection with a small cross section and a steep slope as per construction at the base of a flatland, so that the fire smoke spreads rapidly in case of fire, which is expected to cause damage of human life. Therefore, this study is analyzed the delay effect of fire smoke diffusion according to the installation and non - installation of delay system for fire smoke diffusion at the intersection. Fire fumes were delayed up to 270 seconds when the delay system for fire smoke diffusion was installed at the intersection and it is analyzed that the greater the operating area of the delay system for fire smoke diffusion, the more preventable the damage of human life of the intersection.

Case Study on Technology and Regulation Improvement of Subway Maintenance Monitoring (지하철 유지관리 계측의 기술 및 제도 개선방안 연구)

  • 우종태;김홍석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.303-308
    • /
    • 2000
  • By means of analyzing of monitoring technology and monitoring regulation based on maintenance monitoring system installed in subway tunnel section, it needs monitoring system, development of operating program, monitoring analyzing system and development of analysis method, establishment of maintenance monitoring standard specification, and performance of responsible monitoring supervision for applying to subway monitoring maintenance effectively in future. It requires specialized monitoring and legislation of monitoring subcontract, improvement of monitoring work contract method, establishment the standard payment of monitoring, and effective calibration and correction of monitoring system in the plan of improving monitoring regulation.

  • PDF

Operating Temperature and Time of Rate of Rise Heat Detector (차동식 열감지기의 작동온도와 작동시간)

  • 류호철;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.61-67
    • /
    • 1994
  • Rate of rise heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, simple equations were derived which can be predicted the response time and temperature of the rate of rise heat detector with the results of hot wind tunnel tests and compartment fire experiments.

  • PDF

A Numerical Analysis on the System Impedance in a Fan Cooling System (Fan 냉각장치에서 System 저항에 관한 수치해석)

  • Kim, Dong-Il;Bok, Ki-So;Lee, Seung-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1424-1429
    • /
    • 2004
  • To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance and it has been usually examined with the fan tester(wind tunnel) based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated.

  • PDF

EXPERIMENTAL AND COMPUTATIONAL STUDIES ON HYSTERISYS PHENOMENON OF SUPERSONIC COANDA WALL JETS

  • Kim, Heuy-Dong;Kweon, Oh-Sik;Setoguchi, Toshiaki
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.514-519
    • /
    • 2000
  • Recently a considerable interest is being concentrated on industrial applications of supersonic Coanda wall jets, but the flow physics are not still understood well. It is of practical importance to evaluate the effectiveness of supersonic Coanda wall jet devices fer such industrial purposes. In the present work, experiments and computations were performed to Set a better understanding of the supersonic Coanda jet physics. The experiments were made using a small blow-down wind tunnel. The operating pressure ratio and the Coanda surface configuration were changed to investigate their influences on the wall jet flows. Two-dimensional Navier-Stokes computations were performed using a TVD finite volume scheme to effectively capture the important wave structures of supersonic Coanda jet flows. Both experimental and computational results showed several important hysterical features of the supersonic Coanda wall jets; the attachment and detachment of supersonic Coanda jet were strongly dependent on the change processes of the operating pressure ratio and the detailed flow configuration.

  • PDF

Design of High Power RF Amplifier (고출력 고주파 증폭기의 설계)

  • Nam, S.H.;Jeon, M.H.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.180-182
    • /
    • 1994
  • In an electron storage ring of Pohang Light Source (PLS), electrons lose their energy in every turn by the synchronous radiation. A high power RF amplifier is employed to compensate the electron energy that is lost by the synchronous radiation. The specification of RF amplifier is an continuous output power of 60 kW at 500.082 MHz operating frequency. The power is supplied to RF cavities in the storage ring tunnel. Total number of amplifier system currently required is three. Tile total number will be increased upto five as the operating condition of storage ring is upgraded. The RF amplifier is mainly consisted of a high voltage DC power supply, an intermediate RF power amplifier (IPA), and a klystron tube. In this article, the design of RF amplifier system and characteristics of the klystron tube will be discussed.

  • PDF

A Study on the Facility Installation for Safety Operation of Urban Transit (도시철도의 안전운행을 위한 시설물 설치에 관한 연구)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1323-1325
    • /
    • 2003
  • In field of Urban transit safely, It must be not only secured vehicle but also every areas like power, signal, communication, track, tunnel, operating facilities. Likewise it is very important not only hardware system like vehicles, facilities but also software system like action of engine driver, duty officer. In other to secure safety of hardware, soft ware, it is very important systemic process. In Korea, Many operating companies neglect to invest in safely and ignore technical development about safety because of management. Safely was considered in subway system and many studies were accomplished about safety in subway system in advanced county like U.K, USA. Hence, in this paper, Conditions and improvement of minimum considerable hardware and software are proposed for safe operation in Urban transit.

  • PDF

A Study on the Excavation of the Center Wall for the Evacuation Passageway in the Operating 2-Arch Tunnel (운행 중인 2-Arch 터널의 피난연결통로 신설을 위한 중앙벽체 굴착에 관한 연구)

  • Lee, Jong-Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.454-464
    • /
    • 2021
  • Purpose: There is a need to construct an evacuation passageway for the 2-Arch tunnel, which has been constructed and is in operation. Therefore, it aims to analyze tunnel and center wall behaviour and stability due to excavation of the center wall. Method: We describe the theoretical background of 2-Arch tunnel and evacuation passageway, and focused on analyzing the behaviour of tunnel and wall using 3-dimensional finite element analysis. Parametric analysis according to rock rating was performed with various ground conditions, and the displacement and stress of the center wall were intensively analyzed. Result: With the center wall excavation, the largest amount of settlement was shown in the center of the opening, and the stress was greatest during the first excavation. In addition, it was shown that stress concentration occurred at the top of both openings, and stability reviews considering the concept of allowable stress showed that it exceeded the allowable stress. Conclusion: Although the displacement of the tunnel has secured stability within the allowable standard, the generated stress is found to exceed the allowable standard, so it is necessary to prevent sudden stress release by applying appropriate reinforcement methods during construction.

Improvement of Electrical Properties by Controlling Nickel Plating Temperatures for All Solid Alumina Capacitors

  • Jeong, Myung-Sun;Ju, Byeong-Kwon;Oh, Young-Jei;Lee, Jeon-Kook
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.25.2-25.2
    • /
    • 2011
  • Recently, thin film capacitors used for vehicle inverters are small size, high capacitance, fast response, and large capacitance. But its applications were made up of liquid as electrolyte, so its capacitors are limited to low operating temperature range and the polarity. This research proposes using Ni-P alloys by electroless plating as the electrode instead of liquid electrode. Our substrate has a high aspect ratio and complicated shape because of anodic aluminum oxide (AAO). We used AAO because film thickness and effective surface area are depended on for high capacitance. As the metal electrode instead of electrolyte is injected into AAO, the film capacitor has advantages high voltage, wide operating temperature, and excellent frequency property. However, thin film capacitor made by electroless-plated Ni on AAO for full-filling into etched tunnel was limited from optimizing the deposition process so as to prevent open-through pore structures at the electroless plating owing to complicated morphological structure. In this paper, the electroless plating parameters are controlled by temperature in electroless Ni plating for reducing reaction rate. The Electrical properties with I-V and capacitance density were measured. By using nickel electrode, the capacitance density for the etched and Ni electroless plated films was 100 nFcm-2 while that for a film without any etch tunnel was 12.5 nFcm-2. Breakdown voltage and leakage current are improved, as the properties of metal deposition by electroless plating. The synthesized final nanostructures were characterized by scanning electron microscopy (SEM).

  • PDF

Study of the Self-Propulsion Test and Analysis for the Submerged Body in LCT (대형 캐비테이션터널에서 몰수체 자항시험 및 해석 기법 연구)

  • Ahn, Jong-Woo;Seol, Han-Shin;Lee, Young-Yeon;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • In order to study the self-propulsion test and analysis techniques for the submerged body in Large Cavitation Tunnel (LCT). DARPA Suboff, a submarine model publicly available was manufactured. The resistance results of DARPA Suboff was acquired from the LCT tests and compared with those of DTRC. After the wall blockage correction, the resistance results of LCT were in good agreement with those of DTRC. On the basis of the resistance results of LCT, the self-propulsion tests were conducted in LCT. The test objective was to get the full-scale propeller operating conditions for the propeller cavitation and noise tests. The test results of DARPA Suboff were analyzed in a way similar to the analysis techniques of those of the Towing Tank (TT). Another submerged body, for which self-propulsion tests were conducted in TT, was selected for results verification. The results of LCT were in good agreement with those of TT. On the basis of the present study, it is thought that the operating conditions for the full-scale submerged body can be drawn through LCT tests.