• Title/Summary/Keyword: Open/Short Test

Search Result 98, Processing Time 0.035 seconds

The Management and Evaluation of Speech in Cleft Palate Patients (구개열환자의 언어관리 및 평가)

  • Shin Hyo-Keun;Kim Hyun-Gi
    • Proceedings of the KSPS conference
    • /
    • 1996.02a
    • /
    • pp.23-40
    • /
    • 1996
  • The communicative disorders in cleft palate patients have relationship with the acoustic and He physiological phenomena. Particularily hypernasality is a parameter of cleft palate speech that has been studied by many clinicians and speech pathologists. The degree of hypernasality has been assessed by the listener,s judgement, but perceptual assessements have poor scientific reliability, so objective instruments have been needed to test hypernasality with diagnostics accuracy. This study was analyzed the nasalance score using a Nasometer for cleft palate patients. The simple vowels /a/, /i/, /e/ and the approximants /j/, /w/ were tested for the degree of hypernasality after operation. The phrases containing long and short duration times were used in this study to asses hypeernasality. Fiberopic views shows the open velopharyngeal port that resulted in hypernasality of cleft palate patients. The authors assert the important of the management of cleft palate patients.

  • PDF

A Performance Testing Device of Drycell (건전지의 성능평가 장치)

  • Jeong, Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.171-175
    • /
    • 2011
  • In this paper, I have developed a high-speed and high-resolution measuring device in order to check the performance of drycell. The system is developed for the drycell manufacturing plant. Measuring time is one of key factors to inference on the production speed. So the developed system is designed to generate the classified result up to 1200ea/min. In the other words, each product can be classified within 25ms. There have been many studies to estimate both state of charge as well as state of health, such as OCV (Open Circuit Voltage), SC (Short Circuit) and measuring impedance with frequency pulse. But those methods take a few second due to surface discharge. To overcome the phenomenon, I developed the method to engage the reverse current to two electrodes of battery. As a result, I could achieve to measure the indigenous capacity without the problem of surface discharge.

Real-Time PCB Inspection System using the Line Scan Camera (Line Scan Camera를 이용한 실시간 PCB 검사 시스템)

  • 하종수;이영아;이영동;최강선;고성제
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.81-84
    • /
    • 2002
  • This paper presents the real-time PCB(Printed circuit board) inspection system that can detect thin open/short error using the line scan camera. After a overall introduction of our system, the outline of our inspection methods are described. The goal of our inspection system is the real time and detailed inspection using the line scan camera. To perform inspection processing in real-time, we utilize double buffering structure. In order to solve the problem of unexpectable pixels of PCB, we propose melting process which eliminates unexpectable pixels of PCB. The design and development of our prototype of PCB ins- pection system is discussed and test results are presented to show the effectiveness of the developed inspection algorithm.

  • PDF

Get Social and Get Better: How social computing features help open source software projects (소셜 컴퓨팅 요소가 오픈 소스 개발 프로젝트의 성과에 미치는 영향에 대한 연구: 소셜 코딩 플랫폼 Github 사례를 바탕으로)

  • Choi, Joohee;Choi, Junghong;Moon, Jae Yun
    • Journal of the HCI Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2012
  • In this study, we aim to understand how social computing features affect open source project's outcome based on the representative social coding platform, Github (http://github.com). Though there is growing interest regarding the application and effect of employing social computing features, yet empirical evidences related to the subject are still short. To bridge the gap, we conducted our research based on the following research questions: 1) How the system features of social coding platform are classified? 2) How are the use of system features and project performance related to each other? Qualitative and quantitative analysis are performed: The system features of Github are clustered according to their usage in qualitative analysis, and th relation between the feature uses and project outcome is identified by multiple linear regression test. In conclusion, we found that the use of results is also discussed.

  • PDF

Kinematical Differences of the Male Professional Golfers' 30 Yard Chip Shot and Pitch Shot Motion (남자프로골퍼의 30 야드 칩샷과 피치샷 동작의 운동학적 차이)

  • Pyun, Eun-Kyung;Park, Young-Hoon;Youm, Chang-Hong;Sun, Sheng;Seo, Kuk-Woong;Seo, Kook-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.177-185
    • /
    • 2007
  • Even though there were no clear definitions of the short game and short game distance, short game capability is crucial for a good golf score. Generally, chip shot and pitch shot are regarded as two principal components of the short game. Chip shot is a short, low trajectory shot played to the green or from trouble back into play. Pitch shot is a high trajectory shot of short length. Biomechanical studies were conducted usually to analyze full swing and putting motions. The purpose of the study was to reveal the kinematical differences between professional golfers' 30 yard $53^{\circ}wedge$ chip shot and $56^{\circ}wedge$ pitch shot motions. Fifteen male professional golfers were recruited for the study. Kinematical data were collected by the 60 Hz three-dimensional motion analysis system. Statistical comparisons were made by paired t-test, ANOVA, and Duncan of the SPSS 12.0K with the $\alpha$ value of .05. Results show that both the left hand and the ball were placed left of the center of the left and right foot at address. The left hand position of the chip shot was significantly left side of that of the pitch shot. But the ball position of the pitch shot was significantly right side of that of the chip shot. All body segments aligned to the left of the target line, open, at address. Except shoulder, there were no significant pelvis, knee, and feet alignment differences between chip shot and pitch shot. These differences at address seem for the ball height control. Pitch shot swing motions(the shoulder and pelvis rotation and the club head travel distance) were significantly bigger than those of the chip shot. Club head velocity of the pitch shot was significantly faster than that of the chip shot at the moment of impact. This was for the same shot length control with different lofted clubs. Swing motion differences seem mainly caused by the same shot length control with different ball height control.

The Experiment of High Voltage Capacitor Charger for Pulsed Power Application (펄스전원용 고압커패시터 충전기 시험)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.;Kim, Y.B.;Kim, J.S.;Lee, B.H.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1025_1026
    • /
    • 2009
  • This paper introduces the test a rapid pulsed power charging system for pulsed power application. The charger is designed based on three-phase series resonant inverter followed by air cooled step-up transformers. It has many advantages of lower weight, small size and high efficiency compared with large bulky traditional pulse power charging system. To apply 150kJ pulsed power system, detail test was carried out at various condition and its results shows 90% efficiency at full load condition. And additional experiments such as short, open, and self discharging during charging status are performed to verify reliable operation at abnormal condition and it was confirmed that developed capacitor charger showed very reliable operation all over the tests.

  • PDF

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

Study on the Vertical Pile Capacity of Base-grouted Pile (선단 하부지반 그라우팅된 개단강관말뚝의 연직 지지력에 관한 연구)

  • 정두환;최용규;정성교
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.165-180
    • /
    • 1999
  • Static load tests were performed for open-ended piles, closed-ended piles, piles with grouted toe, and base-grouted piles by using calibration chamber. Then vertical bearing capacities determined from load tests were compared with each other. The stability of base-grouted pile during a simulated seaquake was investigated by changing the penetration depth. Also, static load tests and seaquake tests for 2-piles and 4-piles group were performed. The bearing capacity of the pile grouted inside the toe was 11.2~30.8% less than that of open-ended pile because of reduction of base resistance due to disturbance of base soil under pile toe. The bearing capacity of a base-grouted pile was 23.8~33.9% more than that of an open-ended pile and was similar to that of a closed-ended pile. The bearing capacity of base-grouted group pile was increased ; the bearing capacity of base-grouted 2-piles group increased 14.6~31.8% compared to that of open-ended 2-piles group, and that of base-grouted 4-piles group increased 15.3~22.4% compared to that of open-ended 4-piles group. During the simulated seaquake in deep sea, stability of base-grouted pile was found to be dependent on the pile penetration depth. During seaquake motion, single long base-grouted pile longer than 20m was stable and short base-grouted pile shorter than 12m failed. But relatively long base-grouted pile longer than 12m kept mobility state. Bearing capacity of base-grouted group pile with penetration depth less than 7m was degraded a little bit ; so, base-grouted group pile could maintain mobility condition.

  • PDF

Filed Programmable Logic Control and Test Pattern Generation for IoT Multiple Object switch Control (사물인터넷 환경에서 다중 객체 스위치 제어를 위한 프로그래밍 가능한 로직제어 및 테스트 패턴 형성)

  • Kim, Eung-Ju;Jung, Ji-Hak
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 2020
  • Multi-Channel Switch ICs for IoT have integrated several solid state structure low ON-resistance bi-directional relay MOS switches with level shifter to drive high voltage and they should be independently controlled by external serialized logic control. These devices are designed for using in applications requiring high-voltage switching control by low-voltage control signals, such as medical ultra-sound imaging, ink-jet printer control, bare board open/short and leakage test system using Kelvin 4-terminal measurement method. This paper describes implementation of analog switch control block and its verification using Field programmable Gate Array (FPGA) test pattern generation. Each block has been implemented using Verilog hardware description language then simulated by Modelsim and prototyped in a FPGA board. Compare to conventional IC, The proposed architecture can be applied to fields where multiple entities need to be controlled simultaneously in the IoT environment and the proposed pattern generation method can be applied to test similar types of ICs.

Opening Exercise Therapy with Locking-free Appliance(LA) : Preliminary Study (Locking-free Appliance(LA)를 이용한 개구운동치료 : 예비실험)

  • Jung, Won;Lee, Kyung-Eun;Sun, Sae-Ah;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • Objective: All patients who have the disc displacement with reduction (DDwR) are always not progressive but some of them with significant catching or locking progress to disc displacement without reduction (DDw/oR). In this study, we suggest opening exercise therapy using Locking-free Appliance (LA) to be helpful to prevent progressive derangement. Methods: Retrospectively, a total 37 patients who received exercise treatment using LA was analyzed from January 2010 to December 2011. Patients had been instructed in proper exercise technique to practise for opening and closing of mouth wearing the appliance 30 times a day in locking-free position. Results: None of the patients took a turn for worse to DDw/oR (37 patients). The 16 patients (43.2%, locking-free group) of them could open their mouth without intermittent condylar locking. Measurement of data was analyzed using and Mann-Whitney test. There was no statistically significant difference for age, gender, presence of palpational pain, locking period, VAS quantitative pain score between locking-free group and locking group. Conclusions: In this study, some patients could open their mouth without intermittent locking and did not take a turn for worse to DDw/oR after opening exercise therapy with LA. Furthermore, LA had advantages which were short wearing time, low costs and minimizing patients' uncomfortable compared to conventional treatment method. This therapy can be more appropriate new treatment to prevent progress to DDw/oR.