• 제목/요약/키워드: On-pump

검색결과 3,854건 처리시간 0.029초

비속도의 큰 변화가 극저비속도 원심펌프의 성능에 미치는 영향 (Influence of Large Change of Specific Speed on the Performance of Very Low Specific Speed Centrifugal Pump)

  • 최영도;카가와슈사쿠;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.40-46
    • /
    • 2006
  • Efficiency of a centrifugal pump is known to drop rapidly with a decrease of specific speed $n_s$. However, below $n_s=60\;[min^{-1},\;m^3/min,\;m]$, the pump characteristics are not yet clear. Therefore, present study is aimed to investigate the influence of large change of specific speed on the performance of a very low specific speed centrifugal pump. Moreover, influence of impeller configuration on the performance of very low specific speed pump is investigated. The results show that very low specific speed can be accomplished by reducing volute throat sectional area using circular spacer. Influence of the spacer's location and configuration in the discharge passage on the pump performance is very small. Best efficiency of very low specific speed centrifugal pump decreases proportionally to the specific speed but the best efficiency decreases on a large scale in the range of $n_s<40$. Influence of impeller configuration on the pump performance and radial thrust of centrifugal pump are considerably small in the range of extremely low specific speed $(n_s=25)$.

Study on the Development of Two-Stage Centrifugal Blood Pump for Cardiopulmonary Support System

  • Horiguchi, Hironori;Tsukiya, Tomonori;Nomoto, Takeshi;Takemika, Toratarou;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권4호
    • /
    • pp.142-150
    • /
    • 2014
  • In the cardiopulmonary support system with an ECMO (extracorporeal membrane oxygenation), a higher pump head is demanded for a blood pump. In order to realize a blood pump with higher pump head, higher anti-hemolysis and thrombosis performances, a study on the development of unprecedented multistage blood pump was conducted. In consideration of the application of the blood pump for pediatric patients, a miniature two-stage centrifugal blood pump with the impeller's diameter of 40mm was designed and the performance was examined in experiments and computations. Some useful knowledge for a design of the blood pump with higher anti-hemolysis and thrombosis performances was obtained.

전기 인버터 구동 수압 피스톤 펌프 시스템의 효율 성능에 관한 실험적 연구 (An Experimental Study on the Efficiency of the Water Hydraulic Piston Pump System driven by an Electric Inverter)

  • 함영복;박준형;김성동
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 2006
  • A water hydraulic pump is likely to have serious problems of high leakage, friction and low energy efficiency. A water hydraulic pump has commonly a fixed displacement type and its outlet flow is adjusted by controlling rotation speed of the pump, which can be implemented by using an electric inverter. This study aims to investigate energy efficiency of the water hydraulic pump system which is driven by an electric inverter. The study is based on the experimental results. The pump which is used in the study shows relatively good efficiency and low leakage, low friction as well. The reasons for the good performance of pump is also investigated.

  • PDF

외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석 (Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권4호
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF

Risk Factors of On-Pump Conversion during Off-Pump Coronary Artery Bypass Graft

  • Yoon, Sung Sil;Bang, Jung Hee;Jeong, Sang Seok;Jeong, Jae Hwa;Woo, Jong Soo
    • Journal of Chest Surgery
    • /
    • 제50권5호
    • /
    • pp.355-362
    • /
    • 2017
  • Background: Off-pump coronary artery bypass grafting (OPCABG) procedures can avoid the complications of an on-pump bypass. However, some cases unexpectedly require conversion to cardiopulmonary bypass during OPCABG. The risk factors associated with a sudden need for cardiopulmonary bypass were analyzed. Methods: This retrospective study included 283 subjects scheduled for OPCABG from 2001 to 2010. These were divided into an OPCABG group and an on-pump conversion group. Preoperative, operative, and postoperative variables were compared between the 2 groups. Results: Of the 283 patients scheduled for OPCABG, 47 (16%) were switched to on-pump coronary artery bypass grafting (CABG). The mortality of the both the OPCABG and on-pump conversion groups was not significantly different. The major risk factors for conversion to on-pump CABG were congestive heart failure (CHF) (odds ratio [OR], 3.5; p=0.029), ejection fraction (EF) <35% (OR, 4.4; p=0.012), and preoperative beta-blocker (BB) administration (OR, 0.3; p=0.007). The use of intraoperative (p=0.007) and postoperative (p=0.021) inotropics was significantly higher in the conversion group. The amount of postoperative drainage (p<0.001) and transfusion (p<0.001) also was significantly higher in the conversion group. There were no significant differences in stroke or cardiovascular complications between the groups over the course of short-term and long-term follow-up. Conclusion: Patients who undergo OPCABG and have CHF or a lower EF (<35%) are more likely to undergo on-pump conversion, while preoperative BB administration could help prevent conversions from OPCABG to on-pump CABG.

소형 스크류식 원심펌프의 기액 이상류 특성 (Characteristics of a Small Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;다나카카즈히로;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.9-15
    • /
    • 1999
  • A screw-type centrifugal pump was manufactured to carry primarily solids and its impeller had a wide flow passage. However, there was an effect on the flow passage shape on delay of the choke due to entrained air not being clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For this reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that there was a loss of pump head from single-phase flow to the choke due to air entrainment near the best efficiency point being large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

On-Pump versus Off-pump Myocardial Revascularization in Patients with Renal Insufficiency: Early and Mid-term Results

  • Kim, Hwan-Wook;Lee, Jae-Won;Je, Hyung-Gon;Choi, Soo-Hwan;Jo, Keon-Hyon;Song, Hyun
    • Journal of Chest Surgery
    • /
    • 제44권5호
    • /
    • pp.323-331
    • /
    • 2011
  • Background: Myocardial revascularization in patients with renal insufficiency is challenging to the cardiac surgeon, irrespective of utilizing extracorporeal circulation. This study aimed to compare the number of bypass grafts and the mid-term results and to evaluate independent survival predictors in patients with renal insufficiency undergoing on-pump or off-pump myocardial revascularization. Materials and Methods: We retrospectively analyzed the data of 103 patients with renal insufficiency, who had isolated myocardial revascularization between January 1999 and January 2009. The patients were divided into two groups, the on-pump group and the off-pump group. Results: The off-pump group received a significantly greater number of distal arterial grafts than the on-pump group. However, the mean number of total grafts, the degree of complete revascularization, and survival rate of the patients were not significantly different between the two groups. Multivariate analysis showed the independent predictors for reduced mid-term survival were the number of total grafts and postoperative periodic renal replacement therapy. Off-pump myocardial revascularization does not decrease the number of bypass grafts or influence on the mid-term results for patients with renal insufficiency, compared to on-pump myocardial revascularization. Conclusion: Myocardial revascularization with a large number of total grafts has a beneficial effect on survival in patients with renal insufficiency, irrespective of utilizing extracorporeal bypass.

Osmotic Pump모델 당뇨병 실험동물에서 침자극이 혈당조절 및 베타세포 보호작용에 미치는 영향 (A Study on Serum Glucose Levels and the Pancreatic Beta-cell Protective Effect of Acupuncture on Streptozotocin-treated Rats by Subcutaneous Implantation of Osmotic Pump)

  • 허광욱;강성길;김용석
    • Journal of Acupuncture Research
    • /
    • 제24권4호
    • /
    • pp.115-124
    • /
    • 2007
  • Objective: To evaluate the effect of acupuncture on streptozotocin(STZ)-treated rats by subcutaneous implantation of osmotic pump. Methods: STZ was administered to rats at a low dose with osmotic pump to induce beta cell death and diabetes (STZ osmotic pump model), The experimental animals were divided into 4 groups: 1. The control group which was not treated in the STZ osmotic pump model 2. The sham group which was acupunctured at an arbitrary point in the STZ osmotic pump model 3. The sample A group which was acupunctured at the Chung-wan($CV_{12}$) in the STZ osmotic pump model 4. The sample B group which was acupunctured at the Chok-samni($ST_{36}$) in the STZ osmotic pump model. The effect of acupuncture in the STZ osmotic pump model was observed by measuring the serum glucose level and immunostaining of pancreatic tissue of the rats. Results : STZ injection by subcutaneous implantation of osmotic pump caused hyperglycemia by destroying the pancreatic beta cell selectively. Acupuncture at the Chung-wan acupuncture point($CV_{12}$) and Jhok-samni acupuncture point ($ST_{36}$) in the STZ osmotic pump model separately resulted in a decrease of the serum glucose level. In addition, the cyto-protective effect of the pancreatic beta-cell was detected in the STZ osmotic pump model by acupuncture. And there were few differences between the effects of acupuncture at the CV12 and $ST_{36}$. Conclusion : Acupuncture at the CV12 and ST36 had beneficial effects on Type II diabetes mellitus, and action mechanism of the effect was thought to be concerned with secretion of endogenous beta-endorphin.

  • PDF

토질변화에 따른 Pump 준설능력 산정 (Evaluation of Dredging Capability of Pump Dredger based on Soil Conditions)

  • 박홍신;유영인;김하영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.316-321
    • /
    • 2006
  • The Prouductivity of pump dredger varies very much depend on soil conditions is one of the main factors affecting construction period. Therefore the acculate evaluation of dredging capability of pump dredger considering soil conditions is a main task in dredging projects. After assesing the results of pump dredging on several Gwangyang port projects, some data of Japan standard for pump dredger are similar to those of actual results and a pump dredging capability table is prepared for future evaluation purposes.

  • PDF

입구부 형상이 수중 카고 펌프의 성능에 미치는 영향 (Effects of inlet shape on the performance of a submerged cargo pump)

  • 김준형;최영석;이경용;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제10권6호
    • /
    • pp.44-49
    • /
    • 2007
  • In this paper, effects of inlet shape on the performance of a submerged cargo pump were numerically studied using a commercial CFD code CFX. The inlet shape, especially the gap between pump and suction well, is an important parameter in a point of view of performances of submerged cargo pump due to its effects on the residual and also hydraulic performance of the pump, respectively. To know the optimized gap, the overall performance degradations were calculated with the gap. In addition to that, the flow field through the gap was investigated to explain the effect of velocity non-uniformity on the performance of the pump impeller.