• Title/Summary/Keyword: On-off solenoid

Search Result 103, Processing Time 0.041 seconds

A Study of On-Off Solenoid Actuator (On-Off 솔레노이드 엑츄에이터의 특성 연구)

  • Jeon, Yong-Sik;Kim, Dong-Soo;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.154-155
    • /
    • 2007
  • Put Recently, development of micro valves that operate by compressed air has received significant attention in the fields of the micro fluid chip for medical applications or production lines of semi-conduct chip for electronic goods. Especially it is required that high-speed responsibility and lower power in optimal design of these micro valves. The primary objective of this study is to compare the optimally designed Solenoid Valve with the actually produced one which can highly improve the efficiency by providing optimal current according to mechanical load.

  • PDF

Solenoid Valve Control for Diesel Engines fuel Pump (디젤엔진 연료펌프의 솔레노이드 밸드 PWM 제어)

  • 신우석;이철원;진상호;권순익;강남희;김형동;이흥배;이재기;최규하
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.200-203
    • /
    • 1997
  • This paper describes an study electric injection system for diesel engines. It is needed effective fuel injection which controls the solenoid valve of fuel pump. To solve this, this paper proposes DCC-PWM method which can realize fast reply and low holding current for solenoid valve on/off. For the proposed design method, simulation tools of ACSL are used to analyze the system. And the single-chip microcomputer is used to reduce the size of controller and to improve flexibility. And the system's validity can be verified through the experimental results.

  • PDF

A study on the variable damping characteristics of the continuous controlled semi-active suspension system and the effect analysis of the vehicles motion performance (연속제어방식의 반능동형 전자제어 현가장치의 가변댐퍼 감쇠력 특성 연구 및 차량 운동성능에 미치는 효과 분석)

  • 소상균;조경일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.190-198
    • /
    • 1999
  • Continuously controlled semi-active suspension system may improve ride and handling properties. Here, as a mechanism to control the fluid flow solenoid valve mechanism is introduced and added to the basic passive damper to create damping forces of the shock absorbers. The system may produce continuously controlled damping forces in both solenoid valve only and combination with passive shock absorber including fluid flow is studied, and then the combined model is added to the full vehicle model to evaluate its ride and handling performance. Finally, the simulation results are compared to the vehicle models having similar suspension system.

  • PDF

A simulation study on the dynamics of an antiskid brake systems for automotive vehicles (자동차용 미끄럼 방지 제동 장치의 동특성에 관한 시뮬레이션 연구)

  • 김경훈;조형석;홍예선
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.315-320
    • /
    • 1988
  • This paper considers modelling and control of ABS(Anti-skid Brake System) which avoids dangerous wheel locking due to excessive brake pressure during the vehicle braking. The brake pressure is controlled by on and off's of solenoid valves via the variation of the wheel circumferential deceleration measured using tacho-sensors. The dynamic model between the brake pressure and the wheel acceleration of a vehicle is mathematically derived. The computer simulation shows that the threshold value of the on-off control is critical to the performance of the ABS.

  • PDF

The optimal design by Micro On-Off Valve analysis (Micro On-Off Valve 해석에 의한 최적 설계)

  • Kim D.S.;Park S.W.;Koh C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.285-290
    • /
    • 2005
  • Micro On-Off valves are currently recognized as the core technology in the fields of the micro fluid chip fur medical applications and production lines of semi-conduct chip. Micro valves that operate by compressed air need the high-speed responsibility, repeatability, the absorbability and the uniform pressure by the poppet. In this study, Micro On-Off valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

Solenoid Valve DCC-PWM Control for Diesel Engines Fuel Pump (디젤엔진 연료펌프의 솔레노이드 밸브 DCC-PWM 제어)

  • 신우석;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.85-91
    • /
    • 1998
  • This paper describes an study electric injection system for diesel engines. It is needed effective fuel injection which controls the solenoid valve of fuel pump. To solve this, this paper proposes DCC-PWM method which can realize fast reply and low holding current for solenoid valve on/off. For the proposed design method, simulation tools of ACSL are used to analyze the system. And the single-chip microcomputer is used to reduce the size of controller and to improve flexibility. And the systems validity can be verified through the experimental results.

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

Intelligent control of pneumatic actuator using MPWM (MPWM을 이용한 공압 실린더의 지능제어)

  • 송인성;표성만;안경관;양순용;이병룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.530-535
    • /
    • 2002
  • Pneumatic control system has been applied to build many industrial automation systems. But most of them are sequence control type because of their low costs, safety, reliability, etc. Pneumatic servo system is rarely applied to real industrial fields because accurate position control is very difficult due to its nonlinearity and compressibility of air. In pneumatic servo control system, a pneumatic servo valve can be applied, But it is very expensive and has no advantage of low cost compared with a common pneumatic system. This paper is concerned with the accurate position control of a rodless pneumatic cylinder using on/off solenoid valve. A novel Intelligent Modified Pulse Width Modulation(MPWM) is newly proposed. The control performance of this pneumatic cylinder depends on the external loads. To overcome this problem, switching of control parameter using artificial neural network is newly proposed, which estimates external loads on rodless pneumatic cylinder using this training neural network. As an underlying controller, a state feedback controller using position, velocity and acceleration is applied in the switching control the system. The effectiveness of the proposed control algorithms are demonstrated through experiments nth various loads.

  • PDF

A Study Stability Analysis of a PWM Controlled Hydraulic Equipment (PWM 제어되는 유압장치의 안정성 해석)

  • ;Wennmacher, G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control (고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구)

  • Lee, Yong-Joo;Kim, Byeong-Woo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.