• Title/Summary/Keyword: On-off Control

Search Result 2,551, Processing Time 0.031 seconds

Pressure Ripple Reduction in High Speed On-Off Solenoid Valves Driven by PWM Control (PWM 제어 고속 온-오프 전자밸브에서 발생하는 압력맥동 저감)

  • Kim D.T.;Lee S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.2
    • /
    • pp.8-13
    • /
    • 2005
  • This paper investigates a fast, accurate and inexpensive hydraulic motor speed control system using high speed on-off solenoid valves. In order to retain the advantages of the two position valve and obtain better performance, the valves are operated by pulse width modulation(PWM) control. PWM signal is generated from a LabWIEW program in microcomputer in order to set up various duty ratio and frequency of carrier wave in PWM signal with varying system parameters. As the results of experiments, the speed control of a hydraulic motor was successfully implemented using on-off solenoid valves. In order to attenuate the pressure ripple and speed variation due to discontinuously controlled flow through the on-off valves, a resonator hose fabricated for automobile power steering system was connected between the valve and a hydraulic motor. From experimental results obtained in the hydraulic motor system with a resonator hose, it was ascertained that the resonator hose showed excellent performances in reducing pressure ripple and motor speed variation.

  • PDF

A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal (개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구)

  • Jeong, Heon-Sul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Output Voltage Control Method of a Switched Reluctance Generator using Turn-off Angle Control (소호각 제어를 이용한 Switched Reluctance Generator의 출력 전압 제어)

  • 김영조;전형우;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.356-363
    • /
    • 2001
  • A SRG (Switched Reluctance Generator) has many advantages such as high efficiency, low cost, high-speed capability and robustness compared with other of machine. But the control methods that have been adopted for SRGs are complicated. This paper proposes a simple control method using the PID controller which only controls turn-off angles while keeping turn-on angles of SRG constant. In order to keep the output voltage constant, the turn-off angle for load variations is controlled by using linearity between the generated current and turn-off angle since the reference generated current can be led through the voltage errors between the reference and the actual voltage. The suggested control method enhances the robustness of this system and simplifies the hardware and software by using only the voltage and the speed sensors. The proposed method is verified by experiments.

  • PDF

Tension Control of the Let-off and Take-up System in the Weaving Process Based on Support Vector Regression

  • Han, Dong-Chang;Back, Woon-Jae;Lee, Sang-Hwa;Lee, Hyuk-Jin;Noh, Seok-Hong;Kim, Han-Kil;Park, Jae-Yong;Lee, Suk-Gyu;Chun, Du-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1141-1145
    • /
    • 2005
  • This paper proposes a robust tension control algorithm for the let-off and take-up system driven by servo motor which is robust to disturbance and tension variation by using SVR(Support Vector Regression). Quality of textile goods in fiber manufacturing process highly depends on control of let-off, take-up and tension which are essential for constant tension control of yarn and textile fabrics and correct length of them. The physical properties of textile fabrics are very sensitive to several factors(temperature, humidity, radius change of warp beam etc.) which result in tension change. Rapid development of fiber manufacture machine for higher productivity requires control system for let-off, take-up and tension for robustness to sharp tension-variation and quick response. The validity and the usefulness of the proposed algorithm are thoroughly verified through numerical simulation.

  • PDF

Maximum Torque Operation of SRM by using a Self-tuning Control Method (SRM의 최대 토크 운전을 위한 자기동조 제어)

  • 서종윤;김광헌;장도현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.240-245
    • /
    • 2004
  • This paper presents a Switched Reluctance Motor(SRM) drive using the self-tuning control method to achieve the maximum torque. SRM has the difficulty to research it by an analytic method and to control the speed End torque because of the high nonlinearity. So, in this paper, the self-tuning control method is applied to relevantly controlling turn-on/off angle to operate at the maximum torque. Also, the feedback signals to control the turn-on/off angle are the encoder pulse and the increment of phase current. At first, n adequate turn-off angle is searched by itself and then a turn-on angle is done. As the relationship between turn-on and him-off angle is mutual dependent, the turn-on/off angle is controlled by a real time self-tuning control method in order to maintain the maximum torque. The proposed self-tuning Algorithm is verified by experiments.

Structural Vibration Control Using Semiactive Tuned Mass Damper (건물의 내진성능을 향상시키기 위한 반능동 동조질량감쇠 시스템)

  • Moon, Yeong-Jong;Ji, Han-Rok;Jung, Hyung-Jo;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.645-650
    • /
    • 2006
  • This paper presents the results of a study to verify the sufficient control performance of semiactive tuned mass damper and to identify suitable control methods for semiactive tuned mass damper in structural vibration control. In this study, four control algorithms are considered: on-off displacement based groundhook, on-off velocity based groundhook, clipped optimal and maximum energy dissipation algorithm. For semiactive tuned mass damper, MR damper is considered as a controllable damping device and the command voltage is calculated by the control algorithms. Each of the control theory is applied to the three story shear building excited by three earthquakes. The performance of each algorithm is compared with that of conventional tuned mass damper system using evaluation criteria. The simulation results indicate that semiactive tuned mass damper has control efficiency. Among the control algorithms, on-off displacement based control theory shows the best efficacy and robustness.

  • PDF

A Study Stability Analysis of a PWM Controlled Hydraulic Equipment (PWM 제어되는 유압장치의 안정성 해석)

  • ;Wennmacher, G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

Self-Tuning Control of SRM for Maximum Torque with Current and Shaft Position Feedback

  • Seo Jong-yun;Yang Hyong-yeol;Kim Kwang-Heon;Lim Young-Cheol;Cha Hyun-Rok;Jang Do-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.351-354
    • /
    • 2001
  • In this paper, we present self-tuning control of switched reluctance motor for maximum torque with phase current and shaft position sensor. Determination method of turn-on/off angle is realized by using self-tuning control method. During the sampling time, micro-controller checks the number of pulse from encoder and compare with the number of pre-checked pulse. After micro-controller calculates between two data, it moves forward or backward turn-off angle. When the turn-off angle is fixed optimal turn-off angle, the turn-on angle automatically moves forward or backward by a step using self-tuning control method. And then, optimal turn-off angle is searched once again. As such a repeating process, turn-on/off angle is moved automatically to obtain the maximum torque. The experimental results are presented to validate the self-tuning algorithm.

  • PDF

A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve (유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구)

  • 이재구;김도태;김성동
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF