• Title/Summary/Keyword: On-line mode

Search Result 921, Processing Time 0.03 seconds

In-line Variable Optical Attenuator Based on the Bending of the Tapered Single Mode Fiber

  • Kim, Kwang-Taek;Kang, Ji-Hoon;HwangBo, Seung;Im, Kie-Gon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.349-353
    • /
    • 2009
  • We propose a simple in-line variable optical attenuator (VOA) based on the bending effect of tapered single mode fibers. The influence of the taper structure and the reflective index of the external medium surrounding the taper region on the bending loss of the tapered fiber have been investigated experimentally. An attenuation range exceeding 35 dB and a very low excess loss of < 0.2 dB at 1550 nm were achieved. The measured polarization dependent loss of the present VOA at the attenuation level of 10 dB, 20 dB, and 30 dB were 0.1 dB, 0.2 dB, and 0.5 dB, respectively.

Design of Fuzzy Observer for Nonlinear System using Dynamic Rule Insertion (비선형 시스템에 대한 동적인 규칙 삽입을 이용한 퍼지 관측기 설계)

  • Seo, Ho-Joon;Park, Jang-Hyun;Seo, Sam-Jun;Kim, Dong-Sik;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2308-2310
    • /
    • 2001
  • In the adaptive fuzzy sliding mode control, from a set of a fuzzy IF-THEN rules adaptive fuzzy sliding mode control whose parameters are adjusted on-line according to some adaptation laws is constructed for the purpose of controlling the plant to track a desired trajectory. Most of the research works in nonlinear controller design using fuzzy systems consider the affine system with fixed grid-rule structure based on system state availability. The fixed grid-rule structure makes the order of the controller big unnecessarily, hence the on-line fuzzy rule structure and fuzzy observer based adaptive fuzzy sliding mode controller is proposed to solve system state availability problems. Therefore, adaptive laws of fuzzy parameters for state observer and fuzzy rule structure are established implying whole system stability in the sense of Lyapunov.

  • PDF

Dispersion Analysis for Rectangular Coaxial Line and TEM Cell (네모 동축선과 TEM 셀의 분산관계 해석)

  • Cho, Yong-Heui
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.1
    • /
    • pp.124-130
    • /
    • 2007
  • A rectangular coaxial line is mainly utilized as a transition structure from a coaxial line to a rectangular waveguide. A TEM cell is also widely used to measure the EMC characteristics of a DUT. In order to understand the operations of a rectangular coaxial line and a TEM cell, it is essential to analyze the dispersion relations of a rectangular coaxial line and a TEM cell. In this paper, we present simple yet accurate dispersion relations of the TE and TM higher modes based on the TEM mode. Manipulating a mode-matching technique and a Green's function approach allows us to obtain the analytic dispersion equations of a rectangular coaxial line and a TEM cell. In our approach, a rectangular coaxial line is divided into four L-blocks and its electromagnetic fields representations are easily obtained with a superposition. To verify the convergence of our dispersion relations, we perform numerical computations and compare our results with those of FDTD.

Verilog Modeling of Transmission Line for USB 2.0 High-Speed PHY Interface

  • Seong, Ki-Hwan;Lim, Ji-Hoon;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.463-470
    • /
    • 2014
  • A Verilog model is proposed for transmission lines to perform the all-Verilog simulation of high-speed chip-to-chip interface system, which reduces the simulation time by around 770 times compared to the mixed-mode simulation. The single-pulse response of transmission line in SPICE model is converted into that in Verilog model by converting the full-scale analog signal into an 11-bit digital code after uniform time sampling. The receiver waveform of transmission line is calculated by adding or subtracting the single-pulse response in Verilog model depending on the transmitting digital code values with appropriate time delay. The application of this work to a USB 2.0 high-speed PHY interface reduces the simulation time to less than three minutes with error less than 5% while the mixed-mode simulation takes more than two days for the same circuit.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

Crosstalk among three microstrip transmission lines (세 개의 마이크로스트립 전송선로간의 크로스톡)

  • 최재연;이상설
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.5
    • /
    • pp.14-21
    • /
    • 1997
  • The crosstalk among three identical uniform coupled microstrip transmissiom lines is examined. To analyze the crosstalk, the simultaneous equations for the voltage and current waves on each transmission line are induced from the transmission line equation. The capacitance and the inductance of the line to solve the transmission line equation are calculated by the spectral domain analysis and the space domian analysis. There are three quasi-TEM modes is three microstrip transmission lines and the characteristics mode impedences in each mode are almost equal at a weak coupling state. The crosstalk among three identical microstrip transmission lines is calculated varying the frequency from 50MHz to 3GHz.

  • PDF

A New Algorithm for Unstable Mode Decision in the On-line Transient Stability Assessment (온라인 과도안정도 평가를 위한 새로운 불안정모드 선정 알고리즘)

  • Chang, Dong-Hwan;Kim, Jung-Woo;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1123-1128
    • /
    • 2008
  • The necessity of online dynamic security assessment is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices and energy margin. The method is a new version of our previous paper.[1] Case studies are showing very promising results.

Analysis of Coupling Between Digital Noise and Portable Smart Terminal Antenna According to Antenna Types (휴대용 스마트 단말기 안테나 타입에 따른 디지털 노이즈와 안테나의 결합 분석)

  • Kim, Joonchul
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.873-877
    • /
    • 2019
  • In this paper, we analyze the degree of digital noise coupling for Inverted F Antenna (IFA) and Loop Antenna, which are representative types of portable terminal antenna, using characteristic mode. Firstly, the degree of coupling according to the direction of digital signal lines and characteristic mode current of the printed circuit board (PCB) including the antenna is compared and analyzed, and based on this result, the coupling between WiFi antenna and the front camera noise is analyzed. For analysis, the digital signal line and ground line of the FPCB of the camera module are modeled as a loop feeder that excites the characteristic mode of the PCB ground and the change of noise coupling according to the antenna types are analyzed.

A Study on the Effectiveness of Protective Capacity in a Re-entrant Line (재투입 생산라인에서 방어적 생산능력의 효과성에 관한 연구)

  • 김선민;강현곤
    • Korean Management Science Review
    • /
    • v.17 no.1
    • /
    • pp.17-30
    • /
    • 2000
  • This paper addresses the effect of protective capacity on the lead time and throughput of a re-entrant line where statistical fluctuations exist in the form of variation in processing times and machine breakdowns. The specific framework employed in the paper is a five station re-entrant line structured as a closed network mode. This paper argues that protective capacity can be used in conjunction with WIP inventory in order to reduce the lead time and to increase the increase the throughput of a line. Simulation analyses are included to give insight into the effectiveness of protective capacity.

  • PDF

Adaptive Control for the Conventional Mode of Operation of MEMS Gyroscopes

  • Park, Sungsu;Roberto Horowitz
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.39.2-39
    • /
    • 2002
  • This paper presents adaptive add-on control algorithms for theconventional mode of operation of MEMS z-axis gyroscopes. This scheme is realized by adding an outer loop to a conventional force-balancing scheme that includes a parameter estimation algorithm. The parameter adaptation algorithm estimates the angular rate, identifies and compensates the quadrature error, and may permit on-line automatic mode tuning. The convergence and resolution analysis show that the proposed adaptive add-on control scheme prevents the angular rate estimate from being contaminated by the quadrature error, while keeping ideal resolution performance of a conventional force-balancing scheme.

  • PDF