• Title/Summary/Keyword: Omega factor

Search Result 263, Processing Time 0.024 seconds

Dynamic combination resonance characteristics of doubly curved panels subjected to non-uniform tensile edge loading with damping

  • Udar, Ratnakar. S.;Datta, P.K.
    • Structural Engineering and Mechanics
    • /
    • v.25 no.4
    • /
    • pp.481-500
    • /
    • 2007
  • The dynamic instability of doubly curved panels, subjected to non-uniform tensile in-plane harmonic edge loading $P(t)=P_s+P_d\;{\cos}{\Omega}t$ is investigated. The present work deals with the problem of the occurrence of combination resonances in contrast to simple resonances in parametrically excited doubly curved panels. Analytical expressions for the instability regions are obtained at ${\Omega}={\omega}_m+{\omega}_n$, (${\Omega}$ is the excitation frequency and ${\omega}_m$ and ${\omega}_n$ are the natural frequencies of the system) by using the method of multiple scales. It is shown that, besides the principal instability region at ${\Omega}=2{\omega}_1$, where ${\omega}_1$ is the fundamental frequency, other cases of ${\Omega}={\omega}_m+{\omega}_n$, related to other modes, can be of major importance and yield a significantly enlarged instability region. The effects of edge loading, curvature, damping and the static load factor on dynamic instability behavior of simply supported doubly curved panels are studied. The results show that under localized edge loading, combination resonance zones are as important as simple resonance zones. The effects of damping show that there is a finite critical value of the dynamic load factor for each instability region below which the curved panels cannot become dynamically unstable. This example of simultaneous excitation of two modes, each oscillating steadily at its own natural frequency, may be of considerable interest in vibration testing of actual structures.

Seismic Overstrength of Low-rised RC Frame in Korea (국내 저층 콘크리트 골조의 초과강도)

  • 이영욱
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.28-35
    • /
    • 1998
  • The seismic overstrength factor $\Omega$ is evaluated for 4-story reinforced concrete buildings in Korea(of which seismic intensity is low). The study model is designed according to aseismic guideline research - phase II in Korea. The effect of variation of span length and bay number, dead load is considered, especially including the variation of hardening ration after yielding. And push-over analysis is performed, in which the external and internal frame is connected by rigid-link and the $\Omega$ is calculated using the roof drift ratio at 2%. For Zone I, the mean value of $\Omega$ is ranged form 2.3 to 2.5, For Zone II, from 3.1 to 3.4. For low hardening ratio(3%) after yielding, $\Omega$ has little relations with the number of bay, like as the results of other research. But for 5% hardening ratio, $\Omega$ is increased as the number of bay is increased. Within general gravity-load bound, the variation of D.L. has variation of D. L. has no effect on $\Omega$. And, $\Omega$ is increased as the span length is increased.

  • PDF

The magnetic dependence of 2-dimension quantum optical transition in electron-deformation potential phonon interaction systems in Ge

  • Choi, Hyenil;Cho, Hyunchul;Lee, Suho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.446-454
    • /
    • 2018
  • In this work, we summarize the calculation processes of obtaining a scattering factor using with the equilibrium average projection scheme (EAPS), with moderately weak coupling (MWC) interaction, and obtain the line-shape formula of an electron-deformation phonon interacting system interested in the confinement of electrons by squarwell confinement potentials in quantum two dimensional system.. Through the numerical analysis, we analysis the magnetic dependence of absorption power, P(B) in several temperature and frequency difference dependence of absorption power $P({\Delta}{\omega})$, in several external field, where ${\Delta}{\omega}={\omega}-{\omega}_0$ and ${\omega}({\omega}_0)$ is the angular frequency (the cyclotron resonance frequency). The result of equilibrium average projection scheme (EAPS) in SER-MWC explains the properties of quantum transition quite well.

A GENERALIZATION OF ω-LINKED EXTENSIONS

  • Wu, Xiaoying
    • Bulletin of the Korean Mathematical Society
    • /
    • v.59 no.3
    • /
    • pp.725-743
    • /
    • 2022
  • In this paper, the concepts of ω-linked homomorphisms, the ω𝜙-operation, and DW𝜙 rings are introduced. Also the relationships between ω𝜙-ideals and ω-ideals over a ω-linked homomorphism 𝜙 : R → T are discussed. More precisely, it is shown that every ω𝜙-ideal of T is a ω-ideal of T. Besides, it is shown that if T is not a DW𝜙 ring, then T must have an infinite number of maximal ω𝜙-ideals. Finally we give an application of Cohen's Theorem over ω-factor rings, namely it is shown that an integral domain R is an SM-domain with ω-dim(R) ≤ 1, if and only if for any nonzero ω-ideal I of R, (R/I)ω is an Artinian ring, if and only if for any nonzero element α ∈ R, (R/(a))ω is an Artinian ring, if and only if for any nonzero element α ∈ R, R satisfies the descending chain condition on ω-ideals of R containing a.

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment (전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술)

  • 정재갑;박영태;권성원
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Simulation of Soil Open Auger for Covering Operation of Seed (종자복토작업(種子覆土作業)을 위(爲)한 Open Auger의 Simulation)

  • Jo, Jong Seung;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.12 no.1
    • /
    • pp.108-117
    • /
    • 1985
  • The process of conveying of soil with the open auger to cover the seed completly with less power was reviewed by theoretical analysis. The power efficiency, the reasonable range of RPM of the open auger and the velocity of soil conveying to the direction of the shaft are examined to establish the extent of characteristics of the open auger performance. The results of theoretical analysis and application of similitude are as follows: 1. It is possible to predict the power efficiency by the following equation; ${\eta}_p={\frac{P_n}{P_g}}=({\frac{{\omega}_s}{{\omega}_a}}){\cdot}tan{\gamma}{\frac{mg}{(F_mcos{\alpha}+F_scos{\gamma})}}$ 2. The reasonable range of the revolutions per minute of the open auger was presented as follow to cover completely with less power ; $$\frac{4d(L_a-L_i){\cdot}V_w}{{\pi}(D_o^2-D_s^2){\cdot}r{\cdot}{\frac{{\omega}_s}{{\omega}_a}}{\cdot}tan{\gamma}}{{\leq_-}}{\omega}_a{{\leq_-}}({\frac{{\omega}_a}{{\omega}_s}}){\sqrt{\frac{g}{r}}}$$ 3. The velocity of soil conveying to the direction of the auger shaft may be calculated by the equation; $V_h=({\frac{{\omega}_s}{{\omega}_s}})V_a{\cdot}tan{\gamma}$ 4. The factor of RPM was more important than other factors on the power efficiency.

  • PDF

Fabrication of Tantalum Nitride Thin-Film as High-temperature Strain Gauges (고온 스트레인 게이지용 질화탄탈박막의 제작)

  • 최성규;나경일;남효덕;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.1022-1025
    • /
    • 2001
  • This paper presents the characteristics of TaN thin-film as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4∼20%)N$_2$). The electrical and mechanical characteristics of these films investigated with the thickness range 1650∼1870${\AA}$ and room temperature resistivities in the range 178.3 ${\mu}$$\Omega$cm to 3175.7 ${\mu}$$\Omega$cm. The TaN thin-film strain gauge deposited in Ar-(20%)N$_2$atmosphere is obtained a temperature coefficient of resistance(TCR), 0∼-1357 ppm/$^{\circ}C$ in the temperature range 25∼275$^{\circ}C$ and a high temporal stability with a longitudinal gauge factor, 2.92∼3.47. Because of their high resistivity, low TCR and linear gauge factor, these cermet thin-film may allow high-temperature strain gauges miniaturization.

  • PDF

Lateral Vibration of Beams with a Bonded Lap Joint and Partial Layered Dampers (겹침이음부 및 국부적 층댐퍼를 갖는 보의 횡진동 특성)

  • 박정일;최낙삼
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.174-183
    • /
    • 1999
  • An analytical model for the lateral vibration of beams with a bonded lap joint and partial layered dampers has been proposed in this paper. Both shear and normal forces acting along the interface between the elastic and viscoelastic layers were considered in the vibration analysis. Analytical results were compared with those obtained by a finite element method. Effects of the size and location of layers in partial dampers on system loss factor($\eta_s$) and resonant frequency($\omega_r$) were studied. which showed that partial dampers adhered to the site exhibiting the maximum amplitude of vibration were most influential in the increase of $\eta_s$ and the decrease of $\omega_r$. Specific system loss factor( $\eta_s$ divided by total mass of system) was also evaluated in the analysis.

  • PDF

Fabrication and Characteristics of Transformers for High Power Density SMPS (고밀도 SMPS 용 변압기의 제조와 특성)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jung-Sub;Oh, Yong-Woo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.7-10
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8W capacity, with 70V input voltage and 8.2V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 ${\mu}H$, which was the inductance efficiency of 85~87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 ${\Omega}$ and 0.25 ${\Omega}$ respectively. On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96~0.97 under 120 kHz switching frequency. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

  • PDF