• 제목/요약/키워드: OFFSET

검색결과 3,498건 처리시간 0.031초

Design of a Wide-Frequency-Range, Low-Power Transceiver with Automatic Impedance-Matching Calibration for TV-White-Space Application

  • Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Choi, JinWook;Park, SangHyeon;Kim, InSeong;Pu, YoungGun;Kim, JaeYoung;Hwang, Keum Cheol;Yang, Youngoo;Seo, Munkyo;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권1호
    • /
    • pp.126-142
    • /
    • 2016
  • This paper presents a wide-frequency-range, low-power transceiver with an automatic impedance-matching calibration for TV-white-space (TVWS) application. The wide-range automatic impedance matching calibration (AIMC) is proposed for the Drive Amplifier (DA) and LNA. The optimal $S_{22}$ and $S_{11}$ matching capacitances are selected in the DA and LNA, respectively. Also, the Single Pole Double Throw (SPDT) switch is integrated to share the antenna and matching network between the transmitter and receiver, thereby minimizing the systemic cost. An N-path filter is proposed to reject the large interferers in the TVWS frequency band. The current-driven mixer with a 25% duty LO generator is designed to achieve the high-gain and low-noise figures; also, the frequency synthesizer is designed to generate the wide-range LO signals, and it is used to implement the FSK modulation with a programmable loop bandwidth for multi-rate communication. The TVWS transceiver is implemented in $0.13{\mu}m$, 1-poly, 6-metal CMOS technology. The die area of the transceiver is $4mm{\times}3mm$. The power consumption levels of the transmitter and receiver are 64.35 mW and 39.8 mW, respectively, when the output-power level of the transmitter is +10 dBm at a supply voltage of 3.3 V. The phase noise of the PLL output at Band 2 is -128.3 dBc/Hz with a 1 MHz offset.

하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석 (Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load)

  • 배숙진;정재헌;정승미
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

나선형 인덕터를 이용한 VCO 최적설계 (Optimal Design of VCO Using Spiral Inductor)

  • 김영석;박종욱;김치원;배기성;김남수
    • 대한전자공학회논문지SD
    • /
    • 제39권5호
    • /
    • pp.8-15
    • /
    • 2002
  • 나선형 인덕터를 이용한 VCO를 MOSIS의 HP 0.5㎛ CMOS 공정으로 최적 설계하고 제작하였다. 나선형 인덕터의 SPICE 모델을 이용하여, Q지수(qualify factor)를 동작 주파수에서 최대화하기 위하여 레이아웃 변수인 금속선 폭, 회전수, 내경, 간격 등을 최적화하였다. 만약 동작주파수가 2㎓, 인덕턴스가 약 3nH이고, 금속선 두께 0.8㎛, 절연 산화막 두께 3㎛를 사용하는 MOSIS HP 0.5㎛ CMOS 공정의 경우 금속선 폭은 20 정도로 하는 것이 Q지수를 최대로 함을 확인하였다. 이렇게 최적화된 나선형 인덕터를 LC 공진 탱크에 사용하여 VCO를 설계, 제작 및 측정을 하였다. 측정은 온웨이퍼(on-wafer)상에서 HP8593E 스펙트럼 에널라이저를 이용하였다. 발진신호의 주파수는 약 1.61㎓이고, 컨트롤전압이 0V -2V변화할 때 발진주파수는 약 250㎒(15%) 변화하였으며, 출력 스펙트럼으로부터 중심주파수 1.61㎓에서 offset 주파수가 600㎑ 때의 위상잡음이 -108.4㏈c/㎐ 였다.

달 탐사 시험용 궤도선을 위한 심우주 추적망의 관측값 구현 알고리즘 개발 (Development of a Measurement Data Algorithm of Deep Space Network for Korea Pathfinder Lunar Orbiter mission)

  • 김현정;박상영;김민식;김영광;이은지
    • 한국항공우주학회지
    • /
    • 제45권9호
    • /
    • pp.746-756
    • /
    • 2017
  • 본 연구에서는 한국형 달 탐사 시험용 궤도선을 위한 심우주 추적망 (Deep Space Network)의 관측값을 구현하는 알고리즘을 개발하였다. 이 알고리즘을 활용하여 탐사선의 신호 지연 효과를 관측 모델을 통해 보정해서 계산된 관측값을 생성할 수 있다. 계산된 관측값으로 거리, 도플러, 방위각, 고도각을 생성하였다. 기하학적 데이터 값을 General Mission Analysis Tool (GMAT)의 시나리오를 통해 구하였으며, 계산된 관측값을 구하기 위해서 시간 지연 효과, 대류층 지연 효과, 대류권 내 하전 입자에 의한 지연 효과, 대류권 밖 하전 입자에 의한 지연 효과, 대류층에 의한 굴절 효과, 안테나에 의한 지연 효과를 고려하였다. 관측 모델들을 통해 구한 계산된 관측값은 시험용 궤도선의 정밀 궤도 결정을 위해 사용된다. 본 논문에서 개발한 데이터 시뮬레이션 모듈은 미 항공우주국의 궤도 결정 툴 박스 (Orbit Determination ToolBoX, ODTBX)를 이용해 검증되었다.

CFI(Control Flow Integrity) 적용을 통한 GOT(Global Offset Table) 변조 공격 방지 방안 연구 (CFI Approach to Defend against GOT Overwrite Attacks)

  • 정승훈;황재준;권혁진;신동규
    • 인터넷정보학회논문지
    • /
    • 제21권1호
    • /
    • pp.179-190
    • /
    • 2020
  • 유닉스 계열 시스템 환경에서 GOT 변조(GOT overwrite) 공격은 소프트웨어 권한 탈취를 위한 전통적인 제어흐름 탈취 기법 중 하나이다. 그 동안 GOT 변조를 방어하기 위한 몇 가지 기법들이 제안되었는데, 그 중 프로그램 로딩 단계에서 GOT 영역을 읽기전용 속성으로 메모리 배치하여 실행 시간에 GOT 변조를 원천적으로 차단하는 Full Relro(Relocation Read only) 기법이 가장 효과적인 방어기법으로 알려져 왔다. 하지만, Full Relro 기법은 로딩 시간의 지연을 가져와 시작 성능에 민감한 프로그램의 적용에는 제약이 있고, 라이브러리에 적용시 의존 라이브러리에 의한 연쇄적인 로딩 지연 문제 등으로 라이브러리에는 현재 적용되지 않고 있다. 또한, LLVM을 포함한 다수의 컴파일러들은 Full Relro 기법을 기본 적용하지 않아 실행환경의 프로그램은 GOT 공격에 여전히 취약하다. 이 논문에서는 현재 코드 재사용 공격 방어를 위해 가장 적합한 기법으로 인식되고 있는 CFI(Control Flow Integrity) 기법을 사용한 GOT 보호 장치를 제안한다. LLVM을 기반으로 본 기법을 구현하고 binutils-gdb 프로그램 그룹에 적용해 보안성, 성능, 호환성 등을 평가하였다. 본 CFI 기반 GOT 보호 장치는 우회하기 어렵고, 빠르며 기존 라이브러리 프로그램과도 호환되어 적용가능성이 높다.

뇌파신호의 동기해석을 위한 위상검출기의 성능비교 (Performance Comparison of Phase Detectors for the Synchronization Analysis of Electroencephalographic Signal)

  • 김혜진;이지은;유선국
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.277-284
    • /
    • 2013
  • 뇌파의 위상동기 특성의 해석은 뇌기능 정보 처리 네트웍의 이해에 있어서 중요한 요소이다. 본 연구에서는 위상동기 성능을 분석하기 위하여 시간 국부화 기능을 갖는 웨이블렛 변환방법, 힐버트변환 방법, 복소복조방법을 백색잡음혼입한 뇌파 중심주파수 대역신호에 합성한 모의 데이터와 실제 뇌유발전위에 적용하여 위상옵셋, 위상변화 시점, 대역간 상호간섭을 분석하였다. 모의데이터와 실제 데이터에 대하여 웨이블렛 변환방법이 ${\delta}$, ${\theta}$, ${\alpha}$ 대역신호 분할과 위상동기 성능 분석에 가장 우수 하였으며, 복소복조 방식은 큰 혼입잡음 환경에서는 사용에 한계점이 있었으나 위상변화 시점의 검출에는 좋은 성능을 보였다. 실제 데이터에 대하여 추정한 위상변화시점과 위상옵셋은 복소복조방법이 가장 좋은 성능을 보였다. 실험 관측을 통하여 뇌파의 위상동기 현상의 해석에 웨이블렛 방식이 자장 적절하였으며, ${\delta}$ 대역 이상신호에 대한 위상동기 응용에는 복소복조 방법도 사용될 수 있을 것이다. 특히 웨이블렛 방식과 복조복조방식은 간접적으로 위상변화 시점을 검출하여 뇌기능의 변화시점 추정에 응용될 수 있을 것이다.

욕창 예방 및 치유를 위한 의료용 로봇 침대 제어 시스템 (The Control System of a Medical Robot Bed for Prevention and Healing of Pressure Ulcer)

  • 이영대;김창영;장창준;김정애;임재영
    • 문화기술의 융합
    • /
    • 제6권3호
    • /
    • pp.353-359
    • /
    • 2020
  • 본 연구에서는 욕창 예방과 치유를 위해 개발된 의료용 로봇 침대의 제어기 구조와 제어 알고리즘에 대해 기술한다. 상용의 기존 욕창 예방 매트리스는 수동으로 동작하고 잔존 최대 체압이 욕창 발생 임계 체압을 넘어서기 때문에 이론적으로는 항상 욕창이 발생할 여지가 있지만, 본 연구에 개발된 시스템은 능동형 전기구동 건반을 사용하여 침대의 건반이 하강하면 체압이 0으로 떨어져서 욕창이 발생하지 않는다. 또한, 침대의 건반이 상승하여 욕창 임계 체압 이상이더라도 지속시간을 욕창 발생 임계시간 이내로 하도록 기구와 제어 알고리즘이 설계되어 있어서 욕창 발생 자체가 일어나지 않으며, 이는 바로 상용화가 가능한 욕창 예방 로봇 침대임을 뜻한다. 침대 건반의 모터는 의료용으로 적합한 BLDC 서보 드라이버를 설계한 모터로 되어있고 전장이 단순하여 쉽게 사용할 수 있도록 설계되었으며, CAN(Car Area Network)방식으로 서로 통신한다. 제작된 시스템은 욕창 예방에 효과적인 새로운 의료용 로봇 침대로 욕창으로 고통받는 많은 환자들에게 제공될 수 있도록 보급할 예정이다.

주파수 배가 방법을 이용한 고속 전압 제어 링 발진기 (A High-Speed Voltage-Controlled Ring-Oscillator using a Frequency Doubling Technique)

  • 이석훈;황인석
    • 전자공학회논문지SC
    • /
    • 제47권2호
    • /
    • pp.25-34
    • /
    • 2010
  • 본 논문에서는 주파수 배가 방법을 사용한 초고속 전압 제어 링 발진기를 제안하였다. 제안한 전압 제어 발진기는 TSMC 0.18um 1.8V CMOS 공정을 사용하여 설계하였다. 제안한 주파수 배가 방법은 한 주기 안에서 $90^{\circ}$의 위상차를 가지는 4개의 신호를 AND-OR 연산하여 기본 신호의 두 배 주파수를 가지는 신호를 얻어내는 방법이다. 제안한 발진기는 차동 4단 링 발진기와 NAND 게이트를 사용하여 구성하였다. 전압 제어 링 발진기는 완전 차동 형태로 설계하여 정확하게 $90^{\circ}$의 위상차를 가지는 4개의 신호를 얻을 수 있었으며 공통 모드 잡음에 대해 우수한 잡음 성능을 가지게 되었다. 주파수 배가회로는 AND나 OR 게이트에 비해 집적도가 뛰어난 NAND 게이트를 사용하여 AND-OR 연산을 구현하였다. 설계된 전압 제어 링 발진기는 컨트롤 전압에 따라 3.72GHz에서 8GHz의 출력 주파수를 가지며 4GHz에서 4.7mW의 소비 전력과 1MHz 오프셋 주파수에서 -86.79dBc/Hz의 위상잡음 성능을 가짐을 검증하였다. 기존의 고속 전압 제어 링 발진기와의 비교에서도 모든 면에서 가장 뛰어난 성능을 보였고 저렴한 고속 주파수 합성기와 위상 고정 루프 등에 응용될 수 있음을 보였다.

영상처리를 이용한 핵연료봉의 변형 검사 (Inspection of the Nuclear Fuel Rod Deformation using an Image Processing)

  • 조재완;최영수
    • 대한전자공학회논문지SP
    • /
    • 제47권1호
    • /
    • pp.91-96
    • /
    • 2010
  • 본 논문에서는 핵연료봉의 변형에 대한 고정도 검사방법을 제안한다. 핵 연료봉과 이를 관측하는 영상 센서의 광축을 수직으로 구성한다. 영상 센서의 광축을 기준으로 45도 또는 그보다 높은 각도로 레이저 라인빔을 연료봉 표면에 조사하면 연료봉의 수평 방향 변위가 영상 센서에서는 수직 방향 변위로 관측된다. 핵 연료봉 표면에 일정 각도로 입사된 레이저 라인빔이 영상 센서면에서는 일정 두께를 갖는 포물선 형태로 관측되게 된다. 센서 화면에 나타나는 일정 두께의 포물선을 영상처리하여 타원으로 모델링하고 타원의 장축과 단축의 기울기를 구한다. 포물선의 변곡점과 모델링한 타원의 장축과 단축이 교차하는 지점을 특징점으로 추출한다. 이와 같은 영상처리 알고리즘을 이용하여 핵 연료봉의 수평방향 변위에 따른 특징점 좌표의 수직방향 편차를 계산한다. 크러드가 형성된 핵연료봉 시편에 대해 고해상도 영상센서를 사용하여 실험한 결과 중성자 조사후 핵연료봉의 변형 검사기준인 $150{\mu}m$ 보다 3배 이상 개선된 $50{\mu}m$ 이하의 검사 정밀도를 달성하였다.