• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.025 seconds

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

The value of Dedicated Tc-99m MIBI Scintimammography in the Evaluation of Patients with Palpable Breast Lesions in Comparison with Mammography: Preliminary Result (만져지는 유방 병소를 평가하는데 있어 Tc-99m MIBI 유방스캔과 유방촬영 술의 비교: 예비 결과)

  • Cho, Arthur;Cho, Ho-Jin;Yun, Mi-Jin;Park, Byeong-Woo;Kim, Min-Jung;Kim, Eun-Kyung;Kang, Won-Jun;Lee, Jong-Doo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.48-54
    • /
    • 2009
  • Purpose: There are few studies evaluating the usefulness of dedicated high-resolution scintimammography and no studies using delayed washout with this dedicated high resolution scintimammography for the evaluation of breast lesions. We underwent this study to evaluate the clinical usefulness of Tc-99m MIBI in evaluating patients with palpable breast lesions using dedicated high-resolution scintimammography. Materials and Methods: This study included 19 patients with 23 palpable breast lesions who underwent mammography. Tc-99m MIBI was taken to further characterize these lesions. Scintimammography images were acquired with standard craniocaudal and mediolateral oblique views and delayed images were additionally taken. Final conclusions were based on histopathology, either by biopsy or mastectomy results. Results: Eighteen lesions were malignant and five were benign. Mammography was indeterminate for thirteen lesions, nine of those were malignant. Mammography also categorized one lesion as benign in a dense breast, but scintimammography and pathology results showed malignancy. Of the five benign lesions, two were visible on scintimammography, but delayed images showed washout. Conclusion: Based on our preliminary results, dedicated high resolution scintimammography seems to be very useful in characterizing palpable lesions that were indeterminate or negative on mammography.

Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast (전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향)

  • Yun, Jong Jun;Jeong, Ji Uk;Hwang, Ju Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose : The whole body bone scan on nuclear medicine is a widely accepted examination and procedure. However, unusual nonosseous uptake can be observed, which reflects a rare interaction between the radiopharmacceutical and the patient. This study aimed to evaluate the influence of MRI(Magnetic Resonance Imaging) contrast and $^{99m}Tc$-DPD(Dicarboxpropane diphosphonate) on whole body bone scan. Materials and Methods : We analyzed the 982 patients who were examined by $^{99m}Tc$-DPD on whole body bone scan in nuclear medicine department of pusan national university hospital from january to december 2010. All these 982 patients had MRI contrast administration prior to whole body bone scan. We analyzed laboratory test. Results : 46 patients(men 39, women 7) showed diffuse hepatic uptake on whole body bone scan. These uptakes were disappeared on the follow-up whole body bone scan. There were no significant difference of CBC test, liver function tests and renal function tests. Conclusion : The study might be an indirect evidence that diffuse hepatic and splenic uptake of 99mTc-DPD on whole body bone scan after intravenous administration of Gadolinium(Gd) MRI contrast. To perform a precise examination, Gd-contrast agent should be removed from the body before performing a whole body bone scan.

  • PDF

[I-123]IPT SPECT Dopamine Reuptake Site Imaging: Differences in Normal Controls and Parkinson's Patients by Semiquantitative Analysis Methods ([I-123]IPT SPECT를 이용한 도파민 재섭취부위의 영상화: 반정성적 분석방법을 이용한 정상인과 파킨슨병 환자의 차이)

  • Kim, Hee-Joung;Im, Joo-Hyuck;Yang, Seoung-Oh;Ryu, Jin-Sook;Choi, Yun-Young;Lee, Myung-Chong;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.35-46
    • /
    • 1996
  • Dopamine transporter concentrations have been known to decrease in Parkinson's disease (PD) or increase in Tourette's disorder. The purpose of this study was to evaluate the effectiveness of [I-123]N-(3-iodopropene-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-chlorophenyl) tropane (IPT) as an imaging agent for measuring changes in transporter concentrations with PD. IPT labelled with 6.69+/-0.64 mCi(247.53+/-23.68 MBq) of I-123 was intravenously injected into ten patients(age: 55+/-11) with PD, and six normal controls(NC)(age: 46+/-14) as a bolus. Dynamic SPECT scans of the brain were then performed for 5 minutes each over 120 minutes on a triple headed camera. Time activity curves were generated for the left basal ganglia(LBG), right basal ganglia(RBC), and occipital cortex(OCC). The statistical parameters included the time to peak activity, the contrast ratio of LBG and RBG to OCC at several time points, and the accumulated specific binding counts/mCi/pixel(ASBC) from 0 to 115 minutes. The uptake of IPT in the brains of PD and NC peaked within 10 minutes of injection in all subjects. The maximum target to background ratio in the basal ganglia of PD and NC occurred at 85+/-20 min and 110+/-6 min of injection, respectively. The BG/OCC ratios at 115 minutes for PD and NC were 2.15+/-0.54 and 4.26+/-0.73, respectively. The ASBC at 115 minutes for PD and NC were 152.91+/-50.09 and 289.51+/-49.00, respectively. The ratio of BG/OCC for the NC was significantly higher than the ratio for PD. SPECT data matched with clinical diagnosis for PDs. The ratio between BG and OCC and the ASBC for PD were clearly separated from NC and may be useful outcome measures for clinical diagnosis. The findings suggest that IPT may be a very useful tracer for early diagnosis of PD and study of dopamine reuptake site.

  • PDF

Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network (생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가)

  • Kim, Jong-Wan;Kim, Jung-Yul;Lim, Han-sang;Kim, Jae-sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose Generative Adversarial Network(GAN) is one of deep learning technologies. This is a way to create a real fake image after learning the real image. In this study, after acquiring artificial intelligence images through GAN, We were compared and evaluated with real scan time images. We want to see if these technologies are potentially useful. Materials and Methods 30 patients who underwent 18F-FDG Brain PET/CT scanning at Severance Hospital, were acquired in 15-minute List mode and reconstructed into 1,2,3,4,5 and 15minute images, respectively. 25 out of 30 patients were used as learning images for learning of GAN and 5 patients used as verification images for confirming the learning model. The program was implemented using the Python and Tensorflow frameworks. After learning using the Pix2Pix model of GAN technology, this learning model generated artificial intelligence images. The artificial intelligence image generated in this way were evaluated as Mean Square Error(MSE), Peak Signal to Noise Ratio(PSNR), and Structural Similarity Index(SSIM) with real scan time image. Results The trained model was evaluated with the verification image. As a result, The 15-minute image created by the 5-minute image rather than 1-minute after the start of the scan showed a smaller MSE, and the PSNR and SSIM increased. Conclusion Through this study, it was confirmed that AI imaging technology is applicable. In the future, if these artificial intelligence imaging technologies are applied to nuclear medicine imaging, it will be possible to acquire images even with a short scan time, which can be expected to reduce artifacts caused by patient movement and increase the efficiency of the scanning room.

Study of 68Ga Labelled PET/CT Scan Parameters Optimization (68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구)

  • In Suk Kwak;Hyuk Lee;Si Hwal Kim;Seung Cheol Moon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

The Discriminating Nature of Dopamine Transporter Image in Parkinsonism: The Competency of Dopaminergic Transporter Imaging in Differential Diagnosis of Parkinsonism: $^{123}I-FP-CIT$ SPECT Study (도파민운반체 영상의 파킨슨증 감별진단 성능: $^{123}I-FP-CIT$ SPECT 연구)

  • Kim, Bom-Sahn;Jang, Sung-June;Eo, Jae-Seon;Park, Eun-Kyung;Kim, Yu-Kyeong;Kim, Jong-Min;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.272-279
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the discriminating nature of $^{123}I-FP-CIT$ SPECT in patients with parkinsonism. Methods: $^{123}I-FP-CIT$ SPECT images acquired from the 18 normal controls; NC ($60.4{\pm}10.0$ yr) and 237 patients with parkinsonism ($65.9{\pm}9.2$ yr) were analyzed. From spatialIy normalized images, regional counts of the caudate, putamen, and occipital lobe were obtained using region of interest method. Binding potential (BP) was calculated with the ratio of specific to nonspecific binding activity at equilibrium. Additionally, the BP ratio of putamen to caudate (PCR) and asymmetric Index (ASI) were measured. Results: BPs of NC $3.37{\pm}0.57,\; 3.10{\pm}0.41,\; 3.23{\pm}0.48$ for caudate, putamen, whole striatum, respectively) had no significant difference with those of essential tremor; ET ($3.31{\pm}0.64,\; 3.06{\pm}0.61,\; 3.14{\pm}0.63$) and Alzheimer's disease; AD (3.33 $\pm$0.60, 3.29$\pm$0.79, 3.31$\pm$0.70), but were higher than those of Parkinson's disease; PD (1.92$\pm$0.74, 1.39$\pm$0.68, 1.64$\pm$0.68), multiple system atrophy; MSA (2.36$\pm$1.07, 2.16$\pm$0.91, 2.26$\pm$0.96), and dementia with Lewy body; DLB (1.95$\pm$0.72, 1.64$\pm$0.65, 1.79$\pm$0.66)(p<0.005). PD had statisticalIy lower values of PER and higher values of ASI than those of NC (p<0.005). And PD had significantIy lower value of PCR, higher ASI and lower BP in the putamen and whole striatum than MSA (p<0.05). Conclusion: Dopamine transporter image of $^{123}I-FP-CIT$ SPECT was a good value in differential diagnosis of parkinsonism.

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF