• Title/Summary/Keyword: Normal Condition

Search Result 3,198, Processing Time 0.024 seconds

THE GENERALIZATION OF STYAN MATRIX INEQUALITY ON HERMITIAN MATRICES

  • Zhongpeng, Yang;Xiaoxia, Feng;Meixiang, Chen
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.3_4
    • /
    • pp.673-683
    • /
    • 2009
  • We point out: to make Hermtian matrices A and B satisfy Styan matrix inequality, the condition "positive definite property" demanded in the present literatures is not necessary. Furthermore, on the premise of abandoning positive definite property, we derive Styan matrix inequality of Hadamard product for inverse Hermitian matrices and the sufficient and necessary conditions that the equation holds in our paper.

  • PDF

Current measurement in LN2 using Rogowski coil (로고스키 코일을 이용한 액체 질소 내에서 전류측정)

  • 최용선;차상도;황시돌;최효상
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.239-241
    • /
    • 2003
  • When superconductors are combined with normal conductor as a parallel electric circuit, imbalance of the applied current is happened. For the accurate parameters of the circuit, it is needed to measure the current of the circuit under LN2 condition. In this case, the measurement using Rogowski coil, which is not that affected by changing temperature, can be a method. In this study, using 2 Rogowski coil, the measurement of current was conducted under the condition that is room and LN2 temperature respectively.

  • PDF

AN EXACT LOGARITHMIC-EXPONENTIAL MULTIPLIER PENALTY FUNCTION

  • Lian, Shu-jun
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.5_6
    • /
    • pp.1477-1487
    • /
    • 2010
  • In this paper, we give a solving approach based on a logarithmic-exponential multiplier penalty function for the constrained minimization problem. It is proved exact in the sense that the local optimizers of a nonlinear problem are precisely the local optimizers of the logarithmic-exponential multiplier penalty problem.

Development of Control Algorithm and Detection of the Small Leakage Current (미소 누전전류 검출 및 차단제어기 설계)

  • 반기종;김낙교
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.161-165
    • /
    • 2004
  • In this paper, we have designed the ground faults detection and interrupting controller at normal condition of AC 120v to 240v rating voltage. Ground faults in electrical network have the characteristics of low current, 60㎐ frequency to 2㎑frequency. The load condition are no load and 20A load. The trip level of the controller is 6㎃ with ground faults. The Controller algorithm is implemented using pic16c71 microprocessor.

Assessment of Physical Habitats Characteristics in Naeseongcheon Basin Streams, Korea (내성천 유역 하천의 물리 서식지 특성 평가)

  • Ki Heung Kim;Heareyn Jung;Il Hong;Hong Koo Yeo
    • Ecology and Resilient Infrastructure
    • /
    • v.10 no.4
    • /
    • pp.143-160
    • /
    • 2023
  • This study applied the stream physical habitat assessment system to obtain basic information for river restoration and watershed management in high-gradient and mid-gradient streams in the Naeseongcheon basin. The total length of high-gradient and mid-gradient streams in the Naeseongcheon basin is about 273 km, and as a result of the assessment, it was analyzed that suboptimal reach was about 8.2 km, normal reach was 180.3 km, and marginal reach was 84.7 km. In addition, the physical habitat quality of high-gradient streams was analyzed to be normal condition with an average of 106 points (53%), and in particular, the score of channel/hydraulic category, which is the most important for the habitat of aquatic animals, was analyzed to be normal, close to the limit, with an average of 54 points (45%). The physical habitat quality of mid-gradient streams was found to be in normal condition with an average of 90 points (45%), and the score of channel/hydraulic category was in marginal condition with an average of 39 points (32%). Overall, among 165 reaches of high-gradient and mid-gradient streams in the Naeseongcheon basin, 4 reaches (3%) were evaluated as suboptimal, 119 reaches (72%) were normal, and 42 reaches (25%) were considered marginal. These results showed that the physical habitat of Naeseongcheon was significantly disturbed. Disturbance of stream physical habitat in the Naeseongcheon basin occured due to farmland around stream, urbanization, reservoir construction, and river maintenance.

Effects of Xingjian(LR2),Shaofu(HT8) by Reinforcing and Reducing on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Normal Rats (행간(行間)·소부(少府) 보사침법(補瀉鍼法)이 국소뇌혈류량(局所腦血流量) 및 평균혈압(平均血壓)에 미치는 영향(影響))

  • Shin, Jeong-cheol;Ryu, Chung-ryul;Cho, Myeng-rae
    • Journal of Acupuncture Research
    • /
    • v.20 no.6
    • /
    • pp.190-200
    • /
    • 2003
  • Objective: The purpose of this study is to examine influences by the order, Reduction and Reinforcement in Acupuncture on cerebral hemodynamics [regional cerebral blood flow(rCBF) and mean arterial blood pressure(MABP)] in normal rats. Methods: This experiments was to to investigate eath other changes of rCBF and MABP at Xingjian(LR2)(1st) Shaofu(HT8)(2nd) Reduction, Xingjian(LR2)(1st) Shaofu(HT8)(2nd) Reinforcement, Shaofu(HT8)(1st) Xingjian(LR2)(2st) Reduction and Shaofu(HT8)(1st) Xingjian(LR2)(2st) Reduction in Acupuncture. Results: 1. LR2(1st) HT8(2nd) Reduction in Acupuncture was decreased rCBF and MABP in compared with normal condition. 2. LR2(1st) HT8(2nd) Reinforcement in Acupuncture was significantly decreased rCBF, and was decreased MABP in compared with normal condition. 3. HT8(1st) LR2(2st) Reduction in Acupuncture was decreased rCBF during acupuncture but was recovered rCBF after with-drawing of the neddle. 4. HT8(1st) LR2(2st) Reduction in Acupuncture was decreased MABP during acupuncture and after withdrawing of the neddle. 5. HT8(1st) LR2(2st) Reinforcement in Acupuncture was significantly increased rCBF during acupuncture and 30min after withdrawing of the neddle. 6. HT8(1st) LR2(2st) Reinforcement in Acupuncture was decreased MABP during acupuncture, but was recovered MABP after withdrawing of the neddle. Conclusions: I suggested that LR2 HT8 Reduction in Acupuncture and LR2 HT8 Reinforcement in Acupuncture cause a diverse response of cerebral hemodynas.

  • PDF

An Evaluation of Interface Shear Strength between Geosynthetic Clay Liner and Geomembrane (토목섬유 점토 차수재(GCL)와 지오멤브레인(GM)의 접촉 전단강도 평가)

  • 서민우;김동진;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.137-146
    • /
    • 2002
  • Geomembrane, compacted clay liner, and geosynthetic clay liner (GCL) are widely used to prevent leachate from leaking to adjacent geo-environment at a municipal solid waste (MSW) landfill. Interface shear strength between GCL and geomembrane installed at a landfill side slope is important properties for the safe design of side liner or final cover systems. The interface shear strength between two geosynthetics was estimated by a large direct shear test in this study. The shear strength was evaluated by the Mohr-Coulomb failure criterion. The effects of normal stress, hydration or dry condition, and a hydration method were investigated. The test results show that the interface shear strength and shear behavior varied depending up on the level of normal stress, the type of geosynthetic combinations, and a hydration method. When GCLs were sheared after being hydrated under 6kPa loading, the results were consistent with those published by other researchers. Summaries of friction angles, normal stress and hydration condition is presented. These friction angles could be used as a reference value at a site where similar geosynthetics are installed.

The Evaluation of Interface Shear Strength Between Geomembrane and Ceotextile (지오멤브레인/지오텍스타일의 접촉 전단강도 평가)

  • 서민우;박준범;김운영
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.1
    • /
    • pp.79-89
    • /
    • 2002
  • Various geosynthetics used as liners or protection layers are installed in the solid waste landfills. The interface shear strength between geosynthetics installed at the slope of the landfill is a very important variable for the safe design of the bottom and cover systems in the solid waste landfills. The interface shear strength between Geomembrane and Geotexile is estimated by a large direct shear test in this study, The effects of normal stress, water existing between geosynthetics and surface condition of Geomembrae, i.e. smooth or textured, were investigated. The test results show that the effect varied depending on the level of normal stress and the type of geosynthetic combinations. The shear strength was evaluated by the Mohr-Coulomb failure criterion in this research. The shear strength parameters obtained from tests considering the site specific conditions such as normal stress, dry or wet, and surface condition of geosynthetic should be applied to the design of geosynthetics installed at the slope of the landfill to construct a safe solid waste landfill.

A Study on the Fire Properties of MOF Insulation Cover and Field Condition of 22.9kV Class Power Receiving System (22.9kV 수변전설비의 실태 및 계기용변성기 절연커버의 출화특성에 관한 연구)

  • Choi Chung-Seog;Kim Dong-Woo;Han Woon-Ki;Lee Ki-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.56-60
    • /
    • 2005
  • We studied fire properties of MOF(Metering Out Fit) insulation cover and field condition of 22.9kV power receiving system. $49.5\%$ of formal equipments were installed indoors, whereas $40.8\%$ of informal equipments were installed as H-type. Insulation treatment was not done at a $22.4\%$ ratio of main line($27.7\%$ of transformer, $70.2\%$ of COS, $10.4\%$ of MOF). Fire pattern analysis showed that the fire started at the secondary part of OC wire. In the result of DTA(Differential Thermal Analysis), normal cover showed exothermic reactions at $310^{\circ}C,\;399^{\circ}C\;and\;510^{\circ}C$ (endothermic reactions at $382^{\circ}C$). Whereas damaged cover showed exothermic reactions at $412^{\circ}C$(endothermic reactions at $389^{\circ}C$). In the result of TGA(Thermo Gravimetric Analysis), the thermal weight change of normal cover was similar compared to damaged cover. In the result of FT-IR analysis, normal cover showed absorption peaks at $3,024cm^{-l},\;2,921cm^{-l},\;1,600cm^{-1},\;1,492cm^{-1},\;1,451cm^{-1},\;1,154cm^{-l},\;1,027cm^{-1},\;906cm^{-1}$. Whereas, in case of tracked cover, the absorption peaks that were shown in normal cover disappeared and different absorption peak was shown at $966cm^{-1}$.

Camera Exterior Orientation for Image Registration onto 3D Data (3차원 데이터상에 영상등록을 위한 카메라 외부표정 계산)

  • Chon, Jae-Choon;Ding, Min;Shankar, Sastry
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.5
    • /
    • pp.375-381
    • /
    • 2007
  • A novel method to register images onto 3D data, such as 3D point cloud, 3D vectors, and 3D surfaces, is proposed. The proposed method estimates the exterior orientation of a camera with respective to the 3D data though fitting pairs of the normal vectors of two planes passing a focal point and 2D and 3D lines extracted from an image and the 3D data, respectively. The fitting condition is that the angle between each pair of the normal vectors has to be zero. This condition can be represented as a numerical formula using the inner product of the normal vectors. This paper demonstrates the proposed method can estimate the exterior orientation for the image registration as simulation tests.