• Title/Summary/Keyword: Noise reduction device

Search Result 148, Processing Time 0.025 seconds

Design and Fabrication of a Home-panel Board for Electromagnetic Compatibility (전자파 대응 단위세대 분전반의 설계 및 제작)

  • 길경석;송재용;이종혁;권장우;송동영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.18-25
    • /
    • 2000
  • This paper describes the design and fabrication of a home-panel board for electromagnetic compatibility which can protect home-electric appliances from transient voltages and power line noise. The proposed panel board include a transient voltage blocking device and a EMI filter which consisted of varistors, capacitors, and bus line inductance.A performance test of the prototype panel board, blocking characteristics to transient voltages and reduction characteristics to power line noise, are carried out by using a combination surge generator standardized in IEC and a network analyzer.The results showed that the proposed panel board is satisfied with the surge immunity level of IEC 61000-4-5, and has an over 20[dB] noise reduction performance in ranges from 150[kHz]∼30[MHz].

  • PDF

A Method of White Noise Reduction for Recognizing Cattle's Gulp Downing Sounds

  • Kwak, Ho-Young;Kim, Woo-Chan;Chang, Jin-Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.153-161
    • /
    • 2019
  • In this paper, we proposed a method to measure the feed intake of cattle using the cattle's gulp downing sounds. To measure the sound of cattle's gulp downing, the recording is performed through a wearable device attached to the cattle's neck. A lot of noises are recorded according to the ranching environment. This paper proposed a method for spectralizing raw gulping sound data containing white noise and removing white noise through the signal transformation using a filter. This allows the feed intake to be measured. Through the proposed white noise reduction method, it was possible to extract only the cattle's gulp downing sound, and through this, the number of cattle's gulp downing could be measured. The proposed method in this paper makes it possible to measure cattle's feed intake easily, so that estrus prediction, health care for cattle, and feed management can be done efficiently.

The Effect of Stress Reduction of Human Body by the Vibroacoustic Equipment (음향진동장치에 의한 인체의 스트레스 저감 효과)

  • Moon, D.H.;Kim, Y.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.32-37
    • /
    • 2007
  • The present study describes the effects of music and vibroacoustic stimuli to the relaxation of human body. We have carried out the experiment on 6 human subjects of which are composed 3 men and 3 women. We have investigated the electroencephalogram(EEG) of all subjects before and after the stimuli of which are made a strong noise or the meditatiom music and the acoustic vibration. The vibroacoustic device has transmitted meditation music as vibration between 20Hz and 250Hz to the body. From the experimental results, we made sure the effects that the meditation music and vibroacoustic stimuli influenced the stress reduction of human body for good as alpha wave was increased continuously during the good stimuli and after that.

  • PDF

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Abnormal Detection of CTLS Aircraft Wing Structure using SWT (SWT를 이용한 CTLS항공기 날개 구조물 이상탐지)

  • Shin, Hyun-Sung;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.359-366
    • /
    • 2018
  • In this paper, the noise is removed by using CTLS aircraft installed FBG sensor inside the aircraft wing. We suggest a normal wavelet transform scheme with motion - invariant characteristics for noise reduction. In the case of installing FBG sensors inside the composite material as in CTLS, large and small empty spaces and parts or sections are generated between the adhesive layers, and a signal splitting problem occurs. FBG sensor is not affected by noise. but eletromagnetic, light source, light detector and signal processing device are influeced by noise because these are eletronic components what affected by eletromagnetic wave. because of this, errors are occured. Experimental results show that the noise can be removed using normal wavelet transform and more accurate data detection is possible.

A Study on the Design and Chracteristic Analysis for Noise Cut Transformer (NCT 설계 및 특성 분석에 관한 연구)

  • 이재복;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.146-154
    • /
    • 1998
  • Broadband noise with frequency components in the range from several kHz up the tens of MHz is a major obstacle factor in normal operation of the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices such as filter and surge suppressor are used to cut off the noise. But those devices could not disconnected from the power line, so they result in poor common-mode of NCT as well as insulation characteristics as a isolation transformer in addition faraday shielding and proposed analysis model of NCT having tow functions of surge and noise reduction. The simulated and experimental results for the surge suppression characteristics are compared and evaluated for designed protype 1[kVA] NCT.

  • PDF

Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

  • Hwang, S.M.;Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, K.;Lee, S.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.20-23
    • /
    • 2013
  • For sensitive measurements of micro-Tesla nuclear magnetic resonance (${\mu}T$-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 $fT/{\surd}Hz$, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise ${\mu}T$-NMR experiments.

Development of a Signal Conditioner to Improve the Measurement Reliability of a Microseismic Monitoring System (미소진동 모니터링 시스템의 측정 신뢰도 향상을 위한 시그널 컨디셔너 개발)

  • Cheon, Dae-Sung;Han, Cheol-Min;Lee, Jang Baek
    • Tunnel and Underground Space
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Microseismic monitoring is utilized for the performance verification and safety management of the structure by detecting fine levels of damage. In order to construct a highly reliable microseismic monitoring system, the role of signal conditioner is critical. The signal conditioner helps with accurate data collection and precision control of the device, and performs additional functions such as signal conversion, linearization, and amplification. In this technical report, noise reduction signal conditioner suitable for mining sites was developed and reviewed for the purpose of implementing more precise monitoring by supplementing the previously developed microseismic monitoring system.

Touch-Pen Noise Reduction Using B-Spline Function (B-Spline 곡선을 이용한 터치펜 잡음제거)

  • Lee, Sang-Bum
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.121-126
    • /
    • 2017
  • Recently, a lot of people use touch-pen devices such as smart phones and tab computers. To generate the picture and text, a user can give input or control the touch-pen device through simple or multi-touch gestures by touching the screen with a special stylus pen and/or one or more fingers. The accuracy and response time from the moment of contact with the touch board is very important to the touch device. Therefore, research is needed to find a way of removing the noise included in the touch signal quickly and efficiently. In this paper, we propose a method for removing a noise mixed in with a touch point coordinate which has been caused by a input pen on the touch screen. For effective filtering, the fast sampling of the coordinate corresponding to the noise from the input signal is required primarily. Secondly the total compensation of the touch coordinates using the characteristics of the B-Spline curve is applied to correct coordinates of the points. This method can ensure a real-time response than other algorithms. The applied performance evaluation method is comparing error pixels with evaluation values by dividing 10 intervals on the touch pad diagonally. Usually the average error is 7.1 pixels but our proposed method shows an average 4.1 errors. Therefore, our proposed touch pen method can express the input signal on the coordinates more correctly.

A Study on Radiation Hardening of a Infrared Detector (적외선 탐지소자의 내방사선화 연구)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.