• 제목/요약/키워드: Noise dose

검색결과 270건 처리시간 0.022초

Evaluation of Adult Lung CT Image for Ultra-Low-Dose CT Using Deep Learning Based Reconstruction

  • JO, Jun-Ho;MIN, Hyo-June;JEON, Kwang-Ho;KIM, Yu-Jin;LEE, Sang-Hyeok;KIM, Mi-Sung;JEON, Pil-Hyun;KIM, Daehong;BAEK, Cheol-Ha;LEE, Hakjae
    • 한국인공지능학회지
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2021
  • Although CT has an advantage in describing the three-dimensional anatomical structure of the human body, it also has a disadvantage in that high doses are exposed to the patient. Recently, a deep learning-based image reconstruction method has been used to reduce patient dose. The purpose of this study is to analyze the dose reduction and image quality improvement of deep learning-based reconstruction (DLR) on the adult's chest CT examination. Adult lung phantom was used for image acquisition and analysis. Lung phantom was scanned at ultra-low-dose (ULD), low-dose (LD), and standard dose (SD) modes, and images were reconstructed using FBP (Filtered back projection), IR (Iterative reconstruction), DLR (Deep learning reconstruction) algorithms. Image quality variations with respect to varying imaging doses were evaluated using noise and SNR. At ULD mode, the noise of the DLR image was reduced by 62.42% compared to the FBP image, and at SD mode, the SNR of the DLR image was increased by 159.60% compared to the SNR of the FBP image. Based on this study, it is anticipated that the DLR will not only substantially reduce the chest CT dose but also drastic improvement of the image quality.

외부 공간에서 복합소음에 대한 불쾌감 연구 (Dose-response relationship for annoyance caused by combined noise sources in urban spaces)

  • 이평직;유진;정충일;연준오;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.264-267
    • /
    • 2008
  • Relationship between exposure to combined noise sources and community annoyance have been investigated. Social surveys were conducted in urban spaces near the construction site with road traffics. The question relating to noise annoyance was answered on an 11-point numerical scale and 5-point verbal scale according to ISO 15666. The questionnaire also contained demographic factors, interference with daily activities, health-related symptoms, and noise sensitivity. Noise levels were measured in terms of A-weighted equivalent level ($L_{Aeq}$), and noise mapping technique was applied to predict the noise levels of urban spaces. Synthesis curves for the relationship between noise levels and percentage highly annoyed for combined noise sources were derived, and compared to the curves from a single noise source.

  • PDF

실내 소음기준 설정에 관한 실험적 연구 -동일 건물내 사업장을 중심으로- (An Experimental Study on the Establishment of Indoor Noise Criteria - Focused on Korean Complex Building-)

  • 이태강;국찬;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.9-12
    • /
    • 2008
  • There are many place of business in complex building, and recently claims of noise have increased in those buildings. It is most desirable reducing the noise problems to establish the noise criteria considering the noise source and the receiving place of business, which are derived from the dose-response of noise and results of the actual condition. The degree of response to the transmission noise could be changed with background noise level in the receiving stores. In this research, the subjective evaluation for three different background level in receiving place of business or rooms were investigated from subjective tests. The eight business sound source including aerobic music were used for the test.

  • PDF

Regius 150 Computed Radiography 시스템의 Noise 평가에 관한 연구 (The Noise Evaluation for Ragius 150 CR System)

  • 김정민;민정환;정회원;임은경;양한준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.237-240
    • /
    • 2006
  • CR 시스템의 잡음(Noise)의 주요한 원인은 X-선 양자 모틀이며 그 외에 Imaging plate의 구조 노이즈, 휘진발광체의 광양자 노이즈, 전기계의 노이즈, 양자화 노이즈 등이 있다. Regius 150시스템에서 선량이 $0.1\;mR{\sim}100\;mR$까지 변화할 때 SNR 변화는 0.1 mR에서 8.2부터 선형성을 가지고 증가하고 있다. 이때 최저 SNR 값이 5 이상 되므로 충분한 신뢰성을 확보했다고 할 수 있다. 의료영상시스템의 가장 일반적인 노이즈 평가방법인 Noise Power Spectrum(NPS)을 이산적 화상데이터로부터 얻어진 Pixel 값의 요동으로부터 직접 푸리에 변환하여 구하였다. 주파수 $0.5\;lp/mm{\sim}2.5\;lp/mm$ 구간의 NPS은 선량이 많아질수록 개선되며 1 mR 조사 시 $10^{-4}{\sim}10^{-5}$ 사이에 분포하여, 시판되고 있는 타 회사의 CR시스템과 유사한 노이즈 특성을 가지고 있다.

  • PDF

Deep Learning Algorithm for Simultaneous Noise Reduction and Edge Sharpening in Low-Dose CT Images: A Pilot Study Using Lumbar Spine CT

  • Hyunjung Yeoh;Sung Hwan Hong;Chulkyun Ahn;Ja-Young Choi;Hee-Dong Chae;Hye Jin Yoo;Jong Hyo Kim
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1850-1857
    • /
    • 2021
  • Objective: The purpose of this study was to assess whether a deep learning (DL) algorithm could enable simultaneous noise reduction and edge sharpening in low-dose lumbar spine CT. Materials and Methods: This retrospective study included 52 patients (26 male and 26 female; median age, 60.5 years) who had undergone CT-guided lumbar bone biopsy between October 2015 and April 2020. Initial 100-mAs survey images and 50-mAs intraprocedural images were reconstructed by filtered back projection. Denoising was performed using a vendor-agnostic DL model (ClariCT.AITM, ClariPI) for the 50-mAS images, and the 50-mAs, denoised 50-mAs, and 100-mAs CT images were compared. Noise, signal-to-noise ratio (SNR), and edge rise distance (ERD) for image sharpness were measured. The data were summarized as the mean ± standard deviation for these parameters. Two musculoskeletal radiologists assessed the visibility of the normal anatomical structures. Results: Noise was lower in the denoised 50-mAs images (36.38 ± 7.03 Hounsfield unit [HU]) than the 50-mAs (93.33 ± 25.36 HU) and 100-mAs (63.33 ± 16.09 HU) images (p < 0.001). The SNRs for the images in descending order were as follows: denoised 50-mAs (1.46 ± 0.54), 100-mAs (0.99 ± 0.34), and 50-mAs (0.58 ± 0.18) images (p < 0.001). The denoised 50-mAs images had better edge sharpness than the 100-mAs images at the vertebral body (ERD; 0.94 ± 0.2 mm vs. 1.05 ± 0.24 mm, p = 0.036) and the psoas (ERD; 0.42 ± 0.09 mm vs. 0.50 ± 0.12 mm, p = 0.002). The denoised 50-mAs images significantly improved the visualization of the normal anatomical structures (p < 0.001). Conclusion: DL-based reconstruction may enable simultaneous noise reduction and improvement in image quality with the preservation of edge sharpness on low-dose lumbar spine CT. Investigations on further radiation dose reduction and the clinical applicability of this technique are warranted.

FPSO Topside의 소음특성 파악 및 저감대책 (A Noise Characteristics and Countermeasures of FPSO Topside)

  • 김동해;김성훈;정건화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.73-76
    • /
    • 2005
  • Recently, the demand for the Floating, Production, Storage, and Offloading facility (FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. FPSO vessel dose not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise sources such as gas turbines, compressors, and pumps, are located on top of the hull (Topside area). In general, the noise regulation for the offshore structure is severer than that of the cargo ship and acceptable noise limit of cabin is specified as 45 dB(A). This paper describes the noise characteristics and the countermeasures for FPSO Topside area through investigation of noise analysis and site measurement results. Proper countermeasures, considering the characteristics of sources and receiver spaces, were applied from the noise prediction and various measurement results. Finally, this ship was successfully delivered with excellent noise properties.

  • PDF

전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량 (Quality of Image and Exposure Dose According to kVp, mA and Iterative Reconstruction in Computed Tomography)

  • 차상영;박재윤;이용기;김정훈;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.385-392
    • /
    • 2017
  • 본 연구는 전산화단층촬영에서 관전압과 관전류에 따른 화질과 피폭선량을 연구하고 None IR과 IR (Iterative Reconstruction)의 단계에 따른 영상의 SNR(Signal to Noise Ratio)을 비교하여 영상 화질의 개선정도에 대하여 확인해보고자 하였다. Image J를 이용하여 화질을 측정한 결과 관전압의 증가에 따라 HU (Hounsfield units)와 BN(Background Noise)은 감소하였으며, 이와 반대로 SI (Signal Intensity)와 SNR, $CTDI_{vol}$ (CT dose in dex volume)은 관전압이 높아질수록 증가하였으며, BHU(Background Hounsfield Units)의 변화는 없었다. 관전류의 증가로 인해서 BN이 감소하였고, 반대로 SNR과 CTDI은 증가하였다. 또한 IR의 단계가 높아질수록 HU와 SI, BN이 낮아지고, SNR이 약 10~60% 향상됨을 알 수 있었다. 이를 토대로 임상에서 IR 적용 시 단계적 접근 방식으로 관전압과 관전류를 미세 조정하여 점차적으로 방사선량을 줄여 나가야 할 것이다.

심장 혈관 조영장치에서의 프레임 레이트(f/s) 변화에 따른 상관 관계 분석 : FOV 확대와 Live Zoom을 중점으로 (Analysis of the Relationships according to the Frame (f/s) Change of Cine Imaging in Coronary Angiographic System: With Focus on FOV Enlargement and Live Zoom)

  • 김원효;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.845-852
    • /
    • 2018
  • 본 연구는 심장 혈관 조영술의 투시 영상과 씨네 영상을 획득하는 데 있어서 초당 프레임 횟수를 변화함에 따라 흡수선량과 획득 영상의 화질의 추이를 살펴보는 것을 목적으로 한다. 또, FOV 확대와 Live Zoom이라는 두 가지 확대 모드에 따른 변화도 고찰 대상으로 한다. 인체모형 팬텀을 심장 혈관 조영장치 위에서 초당 프레임 횟수를 7.5, 15, 30 f/s로 설정하고 두 가지 확대 모드에 대하여 각각 5회씩 촬영하였다. 선량의 척도로서는 흡수선량과 에어 커머가 사용되었고, 화질 평가의 척도로는 잡음의 세기로서의 표준 편차(SD), 신호 대 잡음비(SNR)와 대조도 대 잡음비(CNR) 등을 활용하였다. 초당 프레임 횟수가 30부터 15, 7.5 f/s로 감소되었을 때, DAP와 에어 커머는 동일한 비율로 감소하였으나, 화질의 척도인 SD, SNR과 CNR은 거의 변화가 없었다. 확대 모드에의 의존도에 관해서는, Live Zoom이 FOV 확대와 비교하였을 때, DAP, 에어 커머와 SD에 대해서는 통계적 의미 있는 차이를 보이지 않았으나, SNR과 CNR에 있어서는 통계적 유의미한 개선을 보였다. 이러한 실험 결과에 의하여, 초당 프레임 횟수는 화질의 열화 없이 되도록 낮게 설정하는 것이 가능하며, 확대 모드도 추가적인 선량 없이 실시간 확대가 가능한 Live Zoom 모드를 적극적으로 활용 가능하며 이는 화질의 여러 척도의 저하를 가져오지 않음을 알 수 있었다.

다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구 (A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters)

  • 박성우;이종인;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.765-771
    • /
    • 2019
  • Skull X-ray 영상에서 노이즈의 발생은 불가피하며, 이는 영상 화질과 진단 정확도를 저하시키고 디지털 영상 장치의 특성상 오류를 증가시킨다. 이러한 노이즈는 선량을 증가시키면 쉽게 감쇠되긴 하지만 환자가 받는 피폭선량이 더 큰 문제를 야기할 수 있다. 그래서 선량문제를 해결하고 동시에 노이즈를 줄이기 위해저 선량에서 노이즈 감소 알고리즘이 활발히 연구되고 있는데, 초기에 개발되고 널리 사용되어진 median filter와 Wiener filter는 노이즈 감소 효율이 떨어지고 영상경계에 대한 정보가 많이 손실된다는 단점이 있다. 본 연구의 목적은 이전 노이즈 감소효율의 문제점을 보완할 수 있는 total variation (TV) 알고리즘을 skull X-ray 영상에 적용하여 정량적으로 평가하고 비교를 하는 것이다. 이를 위해 Siemens사의 X-ray 장치를 사용하여 성인 skull을 모사할 수 있는 팬텀을 통해 다양한 관전압과 관전류량을 사용하여 실제 skull X-ray 팬텀 영상을 획득하였다. 또한, 각각의 팬텀 영상에 noisy image, median filter, Wiener filter, TV 알고리즘을 적용하였을 때의 대조도 대 잡음비 (CNR)와 변동계수 (COV)를 비교 측정했다. 실험 결과 TV 알고리즘을 적용하였을 때, 모든 조건에서 CNR와 COV 특성이 우수함을 확인할 수 있었다. 결론적으로 이번 연구를 통해 TV 알고리즘을 사용하여 영상의 질을 높일 수 있는지에 대해 확인해 보았고, 이론적으로 CNR 값은 관전류량이 증가할수록 노이즈가 감소함으로 인해 증가하는 것을 알아볼 수 있었다. 반면에, COV는 관전류량이 증가할수록 감소하였으며 관전압이 증가하였을 때 noise는 감소하고 투과량이 증가하여 COV가 감소하는 것을 알아볼 수 있었다.

고속 버스에서의 멀미발생 예측에 관한 연구 (Study on the Motion Sickness Dose Values in Express Buses)

  • 장한기;김승한;송치문;김성환;홍석인
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.548-554
    • /
    • 2003
  • This study alms to investigate the dynamic properties of express buses in the very low frequencies which cause motion sickness Incidence. Since passengers often use express buses for long distance traveling. it is a critical point whether the ride give rise to motion sickness or not. In the study accelerations at the three Points on the floor of the six test vehicles were measured during the driving at constant speeds. By applying the frequency weighting corves suggested in ISO 26.31-1, the Physical quantity of accelerations were changed into the perceptual amount used to judge quantitatively the incidence of motion sickness. Motion sickness dose values were calculated from the frequency weighted time history of acceleration signals, and compared between the vehicles, driving conditions. and the seat positions in the bus. During the 50 minutes' driving on the public road and high ways. the vomiting incidence ratios were seen to range from 0.4 to 0.8 %. which is equivalent to 2.4 to 4.8 % for 5 hours' driving. Unlike the very smooth road conditions considered in this work, motion sickness dose values encountered in real situations are expected to increase.