• 제목/요약/키워드: Nocturnal inversion layer

검색결과 16건 처리시간 0.024초

분지내의 야간 접지역전층 변화와 관련된 기상요소에 대한 연구 (Relations Between the Nocturnal Inversion Layer and Some Meteorological Elements in the Basin)

  • 진병화;황수진
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.369-374
    • /
    • 1998
  • Meteorological measurements were carried out in the basin of Cheong-Kwan located Yang-San near Pusan city, from Oct. 30 to Nov. 1, 1988. According to the measured data, we vended the close relationship between the variation of nocturnal Inversion layer and the meteorological elements. The nocturnal intrersion layer by radiative cooling in this site extends up to 130 meters or so. And the nocturnal jet ap- pears just above or at the top of the inversion layer, and the stronger of the prevailing wind blows, and the lower of the jet level appears. Some meteorological features such as heating, cooling etc., began to change in or in the slightly higher level of the inversion layer, when they are formed, reinforced and disappeared. And the it In the basin preserves its character because It Is not affected by local scale air flow.

  • PDF

Tethersonde와 기상탑 관측 자료를 이용한 울산지역 야간 역전에 따른 대기오염도 변화와의 관계 (Nocturnal Inversion Layer observed by Tethersonde and AWS System and its Relation to Air Pollution at Ulsan)

  • 임윤규;김유근;오인보;송상근
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.555-563
    • /
    • 2005
  • This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003, The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0,76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone $(O_3)$ concentration was lower, while nitrogen dioxide $(NO_2)$ concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide $(SO_2)$ concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.

부산연안에서 관측된 저층대기의 특성에 관한 연구 (Study on the Characteristics of Low Level Atmosphere Observed in Pusan Coastal Ares)

  • 전병일;김유근
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.195-202
    • /
    • 1998
  • The low level atmospheric obsewation carried out to Investigate magnitude, formation and dissipation of nocturnal surface Inversion layer, also to survey relation to each meterological parameter In Inversion layer at Pusan power plant for Oct. 13, 1996. As coastal area, the surface Inversion layer height was relatively high(186m), and after sunset unstable layer formated firom surface to around 40m, and the Inversion layer was left still in the upper layer. The surface Inversion layer dissipated at 0920LST perfectly. The layer that strong Inversion layer was formated, showed steep variation of potential temperature and wand speed and relative humidity.

  • PDF

태풍 우사기와 나리 통과 후 부산지역 미세먼지 농도의 급상승에 관한 연구 (Sudden rise of fine particle concentration after Typhoon USAGI and NARI passage in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.557-564
    • /
    • 2011
  • This study was conducted to investigate the sudden rise of fine particle concentration after the passage of typhoon USAGI and NARI in Busan. Nocturnal inversion layer was formed at atmospheric boundary layer and wind direction changed from southerly wind to northeasterly wind after USAGI passed through Busan. Fine particle concentration in Busan rapidly increased by subsidence of air pollutants released from sources and dust transported from in the vicinity of industrial regions. Wind direction changed from northeasterly wind to southeasterly wind, wind velocity increased and lower atmosphere became extremely unstable after NARI passed through Busan. $PM_{10}$ concentration of Busan increased sharply because of surface dust dispersed by strong wind. Fine particle concentration generally decreases by precipitation and wind after typhoon passes through. However, the concentration can also go up not only by subsidence and transportation in nocturnal inversion layer but also by surface dust which temporarily occurs by strong wind.

동절기 도심지 야간 기온역전에 관한 연구 (A Study on Nocturnal Inversion at Urban Area in Winter)

  • 정해연;이규석
    • 한국환경복원기술학회지
    • /
    • 제13권1호
    • /
    • pp.40-46
    • /
    • 2010
  • In urban area, inversion layer prevents air pollutants from being dispersed. To determine nocturnal inversion characteristics at SookMyung Girls' High School near high-rise residential commercial complex buildings in Seoul, air temperature and humidity data were observed at 10minute interval from December 1st, 2007 to May 2nd, 2008. Temperature-Humidity (T-H) sensors were installed at SMG (SookMyung_Ground) and SMR (SookMyung_Roof), and then these two data were compared, analyzed and examined to illustrate air temperature differences of SMG and SMR. After the analysis, the maximum nocturnal inversion was observed by $3.3^{\circ}C$ at 18:10 on December 26th 2007, at that time the weather condition was clear and weak wind. Nocturnal inversions began 2-3 hours before sunset and it reached maximum inversion just after sunset and continued through nighttime until sunrise or 1-2 hours after sunrise. In terms of seasonal variation nocturnal inversions occurred dominantly in March and April rather than winter season.

계류기구로 관측한 대구시 야간 안정층 특성에 관한 사례연구 (Characteristic of the Nocturnal Inversion Layer observed by Tethersonde in Daegu)

  • 김희종;윤일희;권병혁;허만천
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.155-160
    • /
    • 2002
  • Using measured data at Daegu by tethersonde for the period of 1984∼1987, we have investigated the lower atmospheric boundary layer structure including relationships between inversion layer and meteorological factors(wind and temperature), and the inversion strength and inversion height. The inversion layer was defined from the vertical temperature profile and its strength was analyzed with the wind shear as well as the vertical temperature gradient. From October to January, measured inversion layer isn't destroyed, however, in June, after sun rise, it is destroyed by surface heating and mixed layer is developed from surface. According to Pasquill stability classes, the moderately stable cases dominated. It's the larger vertical temperature gradient the lower SBL height. We have introduced B(bulk turbulence scale) which indicated SBL height. It's larger B, the higher SBL height and vice versa. It was noted that the bulk turbulence scale (B) is appropriate to determine the stable boundary layer height.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

지표 조건에 따른 열대 대기경계층 변화의 사례 연구 (Case Study of Variations in the Tropical Atmospheric Boundary Layer According to the Surface Conditions)

  • 권병혁
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.337-342
    • /
    • 2001
  • The Rondonia Boundary Layer Experiment (RBLE-II) was conceived to collect data the atmospheric boundary layer over two representative surface in the Amazon region of Brazil; tropical forest and a deforested, pasture area. The present study deals with the observations of atmospheric boundary layer growth and decay. Although the atmospheric boundary layer measurements made in RBLE-II were not made simultaneously over the two different surface types, some insights can be gained from analysing and comparing with their structure. The greater depth of the nocturnal boundary layer at the forest site may be due to influence of mechanical turbulence. The pasture site is aerodynamically smoother and so the downward turbulent diffusion will be much pasture than over the forest. The development of the convective boundary layer is stronger over the pasture than over the forest. The influence of the sensible heat flux is important but may be not enough to explain the difference completely. It seems that energy advection may occur from the wet and colder(forest) to the dry and warmer area(pasture), rapidly breaking up the nocturnal inversion. Such advection can explain the abrupt growth of the convective boundary layer at the pasture site during the early morning.

  • PDF

연구노트 산사면에서의 야간 기상요소의 특성에 관한 연구 (On Study on Chatacteristics of Nocturnal Meteorological Parameter at Mountain Slope)

  • 전병일;박재림;박현철
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.633-637
    • /
    • 1999
  • A series of meterological observation using automation weather station(AWS) carried out to investigate characteristics of nocturnal meteorological parameters for 16~17 June 1998 at Buljeongdong mountain slope, Kyungbuk. Dry temperature at valley was lower than mountain because of high lapse rate at valley, so the strong inversion layer occurrenced at mountain slope for nighttime. Contrary of dry temperature, relative humidity of valley was higher than mountain for nighttime. Wind speed at valley from sunset to next day morning was lower than mountain, but that of valley after sunrise was higher than mountain. Wind direction at valley for all observation time were southeasterlies(SE), that of mountain for nighttime were northeasterlies(NE) or northnorthwesterlies(NNW), and that of mountain after sunrise were irregular. Vapor pressure at valley for all observation time was higher mountain, particularly the difference was high for nighttime.

  • PDF

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation

  • Choi, Hyo
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.19-26
    • /
    • 2003
  • The dispersion of recycled particulates in the complex coastal terrain containing Kangnung city, Korea was investigated using a three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). The results show that particulates at the surface of the city that float to the top of thermal internal boundary layer (TIBL) are then transported along the eastern slope of the mountains with the passage of sea breeze and nearly reach the top of the mountains. Those particulates then disperse eastward at this upper level over the coastal sea and finally spread out over the open sea. Total suspended particulate (TSP) concentration near the surface of Kangnung city is very low. At night, synoptic scale westerly winds intensify due to the combined effect of the synoptic scale wind and land breeze descending the eastern slope of the mountains toward the coast and further seaward. This increase in speed causes development of internal gravity waves and a hydraulic jump up to a height of about 1km above the surface over the city. Particulate matter near the top of the mountains also descends the eastern slope of the mountains during the day, reaching the central city area and merges near the surface inside the nocturnal surface inversion layer (NSIL) with a maximum ground level concentration of TSP occurring at 0300 LST. Some particulates were dispersed following the propagation area of internal gravity waves and others in the NSIL are transported eastward to the coastal sea surface, aided by the land breeze. The following morning, particulates dispersed over the coastal sea from the previous night, tend to return to the coastal city of Kangnung with the sea breeze, developing a recycling process and combine with emitted surface particulates during the morning. These processes result in much higher TSP concentration. In the late morning, those particulates float to the top of the TIBL by the intrusion of the sea breeze and the ground level TSP concentration in the city subsequently decreases.

  • PDF