• Title/Summary/Keyword: Ni-Ti endodontic files

Search Result 24, Processing Time 0.025 seconds

Cyclic fatigue test on different rotary NiTi files and handling methods

  • Kim, Jae-Kwan;Kim, Eui-Seong
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.599-599
    • /
    • 2003
  • Endodontic rotary NiTi(Nickel-Titanium) files have several advantages, but they also have some problems. Fracture of instrument is the one of the problems. Cyclic fatigue fracture may not give a previous sign(ex, bending or distortion of the files) before it happen. It is affected by various factors. This study investigated time which takes for cyclic fatigue fracture to happen and fracture patterns with regard to different NiTi files and pecking motion.(omitted)

  • PDF

ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES (회전식 nickel-titanium file을 이용한 유치의 근관치료)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eop;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.620-625
    • /
    • 2001
  • The pulpectomy or root canal treatment on primary teeth is to be done when there is evidence of chronic in flammation or necrosis in the radicular pulp. Due to the tortuous and ribbon-shaped anatomy of the primary teeth, the instrumentation of endodontic hand files and barbed broaches is not an easy procedure. Recently, many automatic Ni-Ti rotary instruments have been developed and has made endodontic treatment easier and faster. This report describes two cases of root canal treatment on primary molars using Ni-Ti rotary files. The cervical constricture was eliminated by the crown-down method, as smaller file proceeded unhindered into the apical third of the canal. In addition, the crown-down technique enhanced the efficacy of the endodontic irrigant. The use of rotary instrumentation for primary teeth seemed to be a more effective way to debride the uneven walls of primary teeth.

  • PDF

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.

Mechanical and geometric features of endodontic instruments and its clinical effect (근관치료 기구의 기계 형태적 특성과 이에 따른 임상적 영향 고찰)

  • Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Introduction: The aim of this paper is to discuss the mechanical and geometric features of Nickel-titanium (NiTi) rotary files and its clinical effects. NiTi rotary files have been introduced to the markets with their own geometries and claims that they have better ability for the root canal shaping than their competitors. The contents of this paper include the (possible) interrelationship between the geometries of NiTi file (eg. tip, taper, helical angle, etc) and clinical performance of the files as follows; - Fracture modes of NiTi rotary files - Non-cutting guiding tip and glide path - Taper and clinical effects - Cross-sectional area and clinical effects - Heat treatments and surface characteristics - Screw-in effect and preservation of root dentin integrity - Designs for reducing screw-in effect Conclusions: Based on the reviewed contents, clinicians may have an advice to use various brands of NiTi rotary instruments regarding their advantages which would fit for clinical situation.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS (대구치에서 회전식 NiTi file의 수명과 파절양상)

  • Kim, Jin-Woo;Ahn, Byung-Doo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.184-192
    • /
    • 2005
  • Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation. The results were as follows: 1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups. 2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files 3. Separations of instruments were occurred at the midpoint of curvatures within the canals 4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples. Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.

Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments (니켈티타늄 전동파일 파절의 예방 및 처치)

  • Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.640-650
    • /
    • 2016
  • Nickel-Titanium (NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

  • PDF

THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE (NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향)

  • Lim, Hyoung-Tae;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.