• Title/Summary/Keyword: Ni-P/Cr

Search Result 334, Processing Time 0.027 seconds

Effects of Heat Treatment Conditions on the Interfacial Reactions and Crack Propagation Behaviors in Electroless Ni/electroplated Cr Coatings (열처리 조건에 따른 무전해 Ni/전해 Cr 이중도금의 계면반응 및 균열성장거동 분석)

  • Son, Kirak;Choi, Myung-Hee;Lee, Kyu Hawn;Byon, Eungsun;Rhee, Byong-Ho;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.69-75
    • /
    • 2016
  • This study investigated the effect of heat treatment conditions not only on the Cr surface crack propagation behaviors but also on the Ni/Cr interfacial reaction characteristics in electroless Ni/electroplated Cr double coating layers on Cu substrate. Clear band layer of Ni-Cr solid solutions were developed at Ni/Cr interface after heat treatment at $750^{\circ}C$ for 6 h. Channeling cracks formed in Cr layer after 1 step heat treatment, that is, heat treatment after Ni/Cr plating, while little channeling cracks formed after 2 step heat treatment, that is, same heat treatments after Ni and Cr plating, respectively, due to residual stress relaxation due to crystallization of Ni layer before Cr plating.

Nano Crystalline Change by Heat Treatment

  • Sun, Yong-Bin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.55-59
    • /
    • 2013
  • Mold die sticking arises from silica filler abrasion to the cavity surface. Ni-P electroplating was examined to substitute conventional hard Cr plating. More than 4% of Phosphorus in the electroplated film produces nano crystal structure and annealing makes $Ni_3P$ precipitated to get hardness values equivalent to hard Cr.

Study on the effect of acid dipping and heat treatment on the adhesion of electroless Ni-P/electrolitic Cr deposition for liquid-fuel rocket combustor (액체 로켄 엔진 연소기 내벽 코팅용 무전해 Ni-P/전해 Cr 도금층의 밀착력 향상을 위한 산세 및 열처리 효과에 관한 연구)

  • Choe, Myeong-Hui;Byeon, Eung-Seon;Park, Yeong-Bae;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.154-154
    • /
    • 2015
  • 현재 액체로켓 엔진 연소기 내벽은 bonding layer NiCrAlY과 Top layer $ZrO_2$가 플라즈마 용사 방식으로 형성 된다. 이는 뛰어난 열 차폐 특성과 작업시간이 짧은 장점이 있지만, bonding layer와 Top layer 사이의 열팽창 계수 차이로 인한 균열 발생 가능성이 내재 되어 있고, 연소실 내벽에 균일한 두께의 코팅층을 형성하기 어렵고 설비가 비싸다는 단점으로 인하여 세라믹 코팅 층을 금속 코팅 층으로 대체 하고자 한다. 금속 코팅층은 모재와의 밀착성이 높고, 우수한 산화 및 부식방지 기능을 가지며 저렴하다는 장점이 있다. 또한 코팅 후 연마 작업이 가능해 연소실 내부형상을 설계조건 대로 유지 할 수 있는 특징이 있다. 따라서 본 연구에서는 연소실 내벽에 적용할 모재, 무전해 Ni-P 도금과 전해 Cr 도금층 사이의 밀착력 향상을 위한 방법에 대한 연구를 하였다. 밀착력 향상을 위한 요소로 전처리 용액과 열처리 시간에 따른 영향을 알아보고자 하였으며, 이를 위해서 5가지의 산세 용액으로 각 시편을 산세 한 후, 6시간, 12시간, 18시간 열처리 하여 단면을 비교하여 열처리에 영향을 알아보고자 하였다. 연구 결과 산세 용액의 영향은 크게 나타나지 않았으며, 열처리 시간이 길수록 Ni-P/Cr의 확산이 더 잘 일어나 확산층이 더 넓어지면서 밀착력이 더 좋아 진 것으로 판단되어 진다.

  • PDF

Investigation of Electronic Structures of TCr2O4 (T = Fe, Co, Ni) Spinel Oxides by Employing Soft X ray Synchrotron Radiation Spectroscopy (연 X선 방사광 분광법을 이용한 TCr2O4(T = Fe, Co, Ni) 스피넬 산화물의 전자구조 연구)

  • Kim, Hyun Woo;Hwang, Jihoon;Kim, D.H.;Lee, Eunsook;Kang, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.5
    • /
    • pp.149-153
    • /
    • 2013
  • The electronic structures of $TCr_2O_4$ (T = Fe, Co, Ni) spinel oxides have been investigated by employing synchrotron radiation-based soft X ray absorption spectroscopy (XAS). The measured 2p XAS spectra of transition-metal ions reveal that Cr ions are trivalent ($Cr^{3+}$), and all the T (T = Fe, Co, Ni) ions are divalent ($Fe^{2+}$, $Co^{2+}$, $Ni^{2+}$). It is also found that most of T (T = Fe, Co, Ni) ions occupy the A sites under the tetrahedral symmetry, while Cr ions occupy mainly the B sites under the octahedral symmetry. These findings show that the structures of $TCr_2O_4$ (T = Fe, Co, Ni) are very close to the normal spinel structures. Based on these findings, it is expected that Jahn-Teller (JT) effects are important in $FeCr_2O_4$ and $NiCr_2O_4$. In contrast, $CoCr_2O_4$ maintains the cubic structure without having the JT distortion since both $Cr^{3+}$ and $Co^{2+}$ ions are non-JT ions. This work suggests that the antiferromagnetic interaction between $Cr^{3+}$ and $T^{2+}$ ions plays an important role in determining the magnetic properties of $TCr_2O_4$ (T = Fe, Co, Ni).

A study on formation mechanism of a microstructure and on morphological stability of a Ni-Cr anode improved creep resistance (Creep 저항성이 향상된 Ni-Cr anode의 미세조직 형성 mechanism 및 구조 안정성에 관한 연구)

  • 정도원;이인성;이덕열;임희천
    • 한국전기화학회:학술대회논문집
    • /
    • 2002.07a
    • /
    • pp.251-258
    • /
    • 2002
  • [ $Ni-10wt.\%Cr$ ] green sheet를 불활성분위기로 $900^{\circ}C$까지 승온시킨 다음 부분산화$(P_{H2}/P_{H2O}=10^{-2})$$1100^{\circ}C$에서 3시간 환원처리를 시키는 소결공정으로 Ni-Cr 고용체 기지 주변에 작은 $Cr_2O_3$ 알갱이가 고르게 분포하는 anode(Anode Sintered in Partial oxidation - Reduction atmosphere; ASPR)를 제조하였으며, creep 변형률이 $2.8\%$로서 미세구조에 따른 creep 특성의 비교를 위해 기존의 환원분위기에서만 소결시킨 anode(Anode Sintered in Reduction atmosphere only; ASR)의 $11\%$보다 우수한 creep 저항성을 나타내었다. $Cr_2O_3$ 알갱이가 분산된 미세구조른 부분산화 시 Cr과 Ni의 산화속도 및 확산속도의 차이로 인해 형성되는 것으로 사료되며, creep 전${\cdot}$후 ASPR 시편의 SEM 및 기공률 분석결과 매우 안정적으로 그 형상 및 구조를 유지하고 있음을 확인할 수 있었다. 또한 ASPR 시편의 전기전도도는 약 $15\times10^6\;S/m$로서 기존 ASR 시편의 전기전도도와 유사함을 알 수 있었다.

  • PDF

Relationship between Serum Levels of Microminerals and Lipids in Korean Adults on Self-Selected Diet (정상 성인의 혈중 미량무기질과 지질과의 관련성에 관한 연구-충남지역 일부 여대생의 혈중 As, Cr, Mn, Se, Ni을 중심으로-)

  • 최미경
    • Korean Journal of Community Nutrition
    • /
    • v.5 no.2
    • /
    • pp.289-296
    • /
    • 2000
  • The purpose of this study was to investigate the relationship and lipids in healthy adults on self-selected diets. These subjects consisted of 40 female college students residing in Chungnam. Anthropometric measure-ments, diet intake measurements, and blood collection were conducted. Serum concentrations of 5 microminerals(As, Cr, Mn, Se, Ni), lipids(triglyceride, total cholesterol, HDL-cholesterol), and glucose were measured by an ICP spectrometer and biochemical analyzer. The results were as follows. The mean age of the subjects was 22.34 years and the mean weight, height, and BMI were 52.89kg, 161.29cm and 20.34, respectively. The mean serum concentrations appeared to be 14.60ug/dl(As), 1.87ug/dl(Cr), 0.18ug/dl(Mn), 23.50ug/dl(Se), 0.21ug/dl(Ni), 60.73mg/dl(triglyceride), 138.49mg/dl(total cholesterol), 65.95mg/dl(HDL-cholesterol), 60.39mg/dl(LDL-cholesterol) and 88.82mg/dl(glucose). When analyzed by Pearson’s correlation coefficient, the serum concentration of Cr was negatively correlated with Ca and vitamin B12 intake(p〈0.05, p〈0.05) respectively, Mn was negatively correlated with Na intake(p〈0.05), Ni, however, was positively correlated with K intake(p〈0.05). The serum concentration of Se was positively correlated with LDL-cholesterol(p〈0.05), Ni, however, negatively correlated with total cholesterol, HDL-cholesterol, LDL-cholesterol, and glucose, respectively(p〈0.001, p〈0.01, p〈0.05). Further studies are needed to clarify the precise micromineral intakes, nutritional assessment of microminerals, and cause-effect relation of microminerals and serum lipids.

  • PDF

Ni Nanoparticle-Graphene Oxide Composites for Speedy and Efficient Removal of Cr(VI) from Wastewater

  • Wang, Wan-Xia;Zhao, Dong-Lin;Wu, Chang-Nian;Chen, Yan;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.31 no.6
    • /
    • pp.345-352
    • /
    • 2021
  • In this study, Ni nanoparticle supported by graphene oxide (GO) (Ni-GO) is successfully synthesized through hydrothermal synthesis and calcination, and Cr(VI) is extracted from aqueous solution. The morphology and structure of Ni-GO composites are characterized by scanning electron microscopy (SEM), trans mission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). High-resolution transmission electron microscopy (HRTEM) and XRD confirms the high dispersion of Ni nanoparticle after support by GO. Loading Ni on GO can obviously enhance the stability of Ni-GO composites. It can be calculated from TGA that the mass percentage of Ni is about 60.67 %. The effects of initial pH and reaction time on Cr(VI) removal ability of Ni-GO are investigated. The results indicate that the removal efficiency of Cr(VI) is greater than that of bared GO. Ni-GO shows fast removal capacity for Cr(VI) (<25 min) with high removal efficiency. Dynamic experiments show that the removal process conforms to the quasi-second order model of adsorption, which indicates that the rate control step of the removal process is chemical adsorption. The removal capacity increases with the increase of temperature, indicating that the reaction of Cr(VI) on Ni-GO composites is endothermic and spontaneous. Combined with tests and characterization, the mechanism of Cr(VI) removal by rapidly adsorption on the surface of Ni-GO and reduction by Ni nanoparticle is investigated. The above results show that Ni-GO can be used as a potential remediation agent for Cr(VI)-contaminated groundwater.

Adsorption Characteristics of Ni2+, Zn2+ and Cr3+ by Zeolite Synthesized from Jeju Scoria (제주 스코리아로부터 합성한 제올라이트에 의한 Ni2+, Zn2+ 및 Cr3+의 흡착 특성)

  • Kim, Jung-Tae;Lee, Chang-Han;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.29 no.7
    • /
    • pp.739-748
    • /
    • 2020
  • The characteristics of heavy metal ion (Ni2+, Zn2+, and Cr3+) adsorption by zeolite synthesized from Jeju scoria using the fusion and hydrothermal method, were studied. The synthetic zeolite was identified as a Na-A zeolite by X-ray diffraction analysis and scanning electron microscopy images. The equilibrium of heavy metal ion adsorption by synthetic zeolite was reached within 60 min for Ni2+ and Zn2+, and 90 min for Cr3+. The uptake of heavy metal ions increased with increasing pH in the range of pH 3-6 and the uptake decreased in the order of Cr3+ > Zn2+ > Ni2+. For initial heavy metal concentrations of 20-250 mg/L at nonadjusted pH, the adsoption of heavy metal ions was well described by the pseudo second-order kinetic model and was well fitted by the Langmuir isotherm model. The maximum uptake of heavy metal ions obtained from the Langmuir model, decreased in the order of Zn2+ > Ni2+ > Cr3+, differing from the effect of pH on the uptake, which was mainly based on the different pH of the solutions.

Study on the Casting Ability of Ni-Cr Alloys for Crown and Bridge (관교의치용 Ni-Cr 합금의 주조성에 관한 연구)

  • Lee, In-Kyu;Kim, Yun-Su
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.47-54
    • /
    • 1988
  • The purpose of this study is to evaluate the castability of Ni-Cr alloys for crown and bridge. New young, Hi-Crown and CB-80 which are widely used in dental laboratory were chosen, casting and increased the temperature of furnace 100$^{\circ}C$ of each 7 grades from 600$^{\circ}C$ to 1200$^{\circ}C$. The results are as follows : 1. CB-80 is the most prominent castability among the three Ni-Cr alloys which are Hi-Crown, New-young and Hi-Cr. 2. The good burning temperatures of casting for CB-8p are 900$^{\circ}C$, 100$^{\circ}C$ and 1100$^{\circ}C$ which are obtained four complate casting body of five former patterns. 3. The most proper burning temperature for three Ni-Cr alloys is 900$^{\circ}C$.

  • PDF

Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements (가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성)

  • 황택성;이선아;황계순
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.765-773
    • /
    • 2001
  • In In order to remove harmful trace elements such as $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$ from water, we synthesized AN-co-(MMA/IA) according to various mole ratio of monomers and spun by wet-spinning. And multi-functional PAN ion exchangers were prepared by hydrolysis. We observed structure, degree of functionalization, ion exchange capacity, distribution coefficient and mechanical properties for ion exchanger. Anion exchange capacity decreased in 4.5 ~ 4.2 meq/g with increasing of IA content and cation exchange capacity increased in 1.8 ~ 2.2 meq/g. Tensile strength of the ion exchanger increased up to 0.008 mol% IA content and appeared maximum value by 216$kg/cm^2$Distribution coefficient for AN-co-(MMA/IA) ion exchanger appeared maximum value for Co(II), Ni(II) in pH 5-6 range and for Cr(III) in pH 3-4 range. And the adsorption capacity was in the order of Cr(III) > Co(II) > Ni(II) for multicomponent in continuous process.

  • PDF