• Title/Summary/Keyword: Neutral System

Search Result 1,091, Processing Time 0.028 seconds

Comparison between PY and YP on Bleach Efficiency of White Ledger according to Deinking Method (탈묵방법에 따른 백상폐지의 표백효율에 미치는 PY와 YP간의 비교)

  • 백기현;안병준
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.3
    • /
    • pp.37-43
    • /
    • 2001
  • The bleach efficiency between PY and YP bleaching of pulps, which were deinked in neutral (cellulase) and alkaline (NaOH, NaOH/${Na_2}{SiO_3}$) ranges, and were treated on kneader, was compared in this study. The brightness of pulps (84.8~88.4% ISO) which were deinked in alkaline or neutral ranges increased up to 88.4%~88.8% ISO after PY or YP bleaching. There was no difference in the brightness between PY and YP bleaching. And the dirt count of bleached pulps was similar each other at the range of 17~38 ppm. The tensile index of bleached pulps was slightly higher in PY bleaching than those in YP bleaching. While with the treatment of kneading, the brightness and dirt count decreased remarkably compared to those of no-kneading. However, the sharp difference in the brightnesses or in dirt count of bleached pulps decreased after bleaching. The brightness of bleached pulps at YP stages was only numberically higher than those at PY stages without regard to the treatment of kneading. Therefore, in the case of the neutral deinkiing process, the conversion of PY bleaching stages to YP bleaching stages was profitable to water loop system, and was harmless in the aspect of the bleach efficiency.

  • PDF

Influence of Upper Trapezius and Sternocleidomastoid Muscle Activation according to Cervical Flexion Angle in Sitting Posture

  • Sung-Min Son
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.5
    • /
    • pp.151-155
    • /
    • 2023
  • Purpose: This study examined the effect of the degree of neck flexion on the muscle activity of the upper trapezius and sternocleidomastoid muscles in the sitting position. Methods: Twenty-five healthy young adults participated in this study. The study was designed to compare the muscle activity of the upper trapezius and sternocleidomastoid muscles according to the neck flexion angle under the three conditions (neutral position, 15° neck flexion, and 45° neck flexion) in the sitting position. During the neck position of three conditions in sitting, the electromyography (EMG) data (% maximum voluntary isometric contraction) of the muscles were recorded using a wireless surface EMG system. Results: The muscle activity of the upper trapezius muscle and the sternocleidomastoid muscles showed a significant difference according to the three-neck position conditions (p<0.05), and in the post-hoc test results, both muscles showed significant differences between the neutral position and 15° flexion, the neutral position and 45° flexion, and the 15° flexion and 45° flexion, respectively. Conclusion: The load on the muscles around the neck and shoulders increased as the neck flexion angle increased. This suggests that performing various daily activities and tasks with the neck as neutral as possible can prevent muscle fatigue or musculoskeletal disorders.

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

A Study of the Lipid Components in Egg Yolk Oil (난황유의 지질성분에 관한 연구)

  • 김종숙;고무석;최옥자
    • Korean journal of food and cookery science
    • /
    • v.12 no.3
    • /
    • pp.295-299
    • /
    • 1996
  • Egg yolk oil was obtained from a roasting and Pressure egg yolks obtained from cage system, open barn system, respectively. Lipids in egg yolk oil were extracted with a mixture of chroform: methanol (2:1, v/v) and fractionated into neutral lipid, glycolipid and phospholipid by silicic aicd column chromatography. Lipid components of each fraction were determined by thin layer chromatography (TLC). The results were sum- marized as follows: lipid content of egg yolk from each cage system (A) and open barn system (B) was 31. 05% and 33.34%, and the lipid is made up of neutral lipid 76.60%, 71.23%, glycolipid 3.95%, 5.03% and phospholipids 19.45%, 23.74% respectively. Triglycerides (A: 59.3%, B: 56.3%) were the major components among the neutral lipids; monoglycerides, diglycerides, free sterols, and free fatty acids were the minor cop- monents. The major components of the glycolipids were digalactosyl diglycerides (A: 98.3%, B: 97.8%), the other components were cerebrosides. The major components of the phophoslipids were phosphatidyl choline plus phosphatidyl serine (A: 58.6%, B: 59.8%) the other components were lecithin plus sphingomyelin.

  • PDF

Classification of Emotional States of Interest and Neutral Using Features from Pulse Wave Signal

  • Phongsuphap, Sukanya;Sopharak, Akara
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.682-685
    • /
    • 2004
  • This paper investigated a method for classifying emotional states by using pulse wave signal. It focused on finding effective features for emotional state classification. The emptional states considered here consisted of interest and neutral. Classification experiments utilized 65 and 60 samples of interest and neutral states respectively. We have investigated 19 features derived from pulse wave signals by using both time domain and frequency domain analysis methods with 2 classifiers of minimum distance (normalized Euclidean distanece) and ${\kappa}$-Nearest Neighbour. The Leave-one-out cross validation was used as an evaluation mehtod. Based on experimental results, the most efficient features were a combination of 4 features consisting of (i) the mean of the first differences of the smoothed pulse rate time series signal, (ii) the mean of absolute values of the second differences of thel normalized interbeat intervals, (iii) the root mean square successive difference, and (iv) the power in high frequency range in normalized unit, which provided 80.8% average accuracy with ${\kappa}$-Nearest Neighbour classifier.

  • PDF

A Study on the Streaming Electrification in the Super-high Voltage Model Transformer (초고압 대용량 모델변압기의 유동대전 현상에 관한 연구(전압무인가))

  • 이덕출;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.619-625
    • /
    • 1991
  • Phenomena of streaming electrification of insulting oil(T.O) is studied where the oil is contacted with solid insulating materials when it is pumped through a circulating system in a large power transformer. The leakage current, the electrical potential at the neutral terminal point of the transformer and the surface electrical potential of the oil are investigated. And the leakage current from the neutral terminal point is measured as a function of a bias polarity applied to a transformer case to investigate the polarty of ion which is absorbed in the case at the interface between the case and oil. As a result, it is found that insulating materials, and it is suggested that the leakage current is the sum of the relaxation current by positive charge from insulating oil to the neutral terminal point and by electrification current from negative charge electrified by the contact with solid insulating materials.

  • PDF

Delay-Dependent Observer-Based Control for a Class of Neutral Systems with Time-Varying Delays (시간 변동 시간 지연을 가지는 뉴트럴 시스템의 관측기 설계에 관한 연구)

  • Song, Min-Guk;Ju, Yeong-Hun;Park, Jin-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.372-375
    • /
    • 2007
  • 본 논문은 시간 변동 시간 지연을 가지는 선형 Neutral 시스템에 관한 관측기 설계에 대해서 논의한다. 시간 지연을 가지는 시스템의 안정도를 판별하기 위하여 Lyapunov-Krasovskii의 이론을 도입한다. 시스템의 안정도를 위한 조건으로 시간 변동 시간 지연에 종속적인 충분조건을 제시한다. 선형 행렬 부등식을 이용하여 관측기의 이득값을 설계하며, 오차 상태 방정식의 안정도를 판별한다. 본 논문의 결과는 Luenberger가 제안한 관측기의 일반적인 결과를 나타낸다. 모의실험을 통해 논문의 결과를 입증하였다.

  • PDF

Study of Neutral Point Potential Variation for Three-Level NPC Inverter under Fault Condition (3레벨 NPC인버터 고장 시 중성점 전압변동에 관한 연구)

  • Park, Jong-Je;Kim, Tae-Jin;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.385-387
    • /
    • 2008
  • Three-level Diode Clamped Multilevel Inverter, generally known as Neutral-Point-Clamped(NPC) inverter, has an inherent problem causing Neutral Point(NP) potential variation. Until now, in many literatures NP potential problem has been investigated and lots of solutions have also been proposed. However, in the case of NP potential variation was rarely published from the standpoint of reliability. In this paper, NP potential is analytically investigated both normal and fault conditions under carrier based PWM. Subsequently, relation between fault detection time and size of capacitor is analyzed. This information is explored by simulation results, which contribute to enhance the reliability of the NPC inverter system.

  • PDF

On Guaranteed Cost Control of Uncertain Neutral Systems (섭동을 갖는 뉴트럴 시스템의 성능보장 안정화에 관하여)

  • Park, Ju-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.3
    • /
    • pp.129-133
    • /
    • 2003
  • In this paper, we consider the robust guaranteed cost control problem for a class of uncertain neutral systems with given quadratic cost functions. The uncertainty is assumed to be norm-bounded and time-varying. The goal in this study is to design the memoryless state feedback controller such that the closed-loop system is asymptotically stable and the closed-loop cost function value is not more than a specified upper bound lot all admissible uncertainty. Some criteria for the existence of such controllers are derived based on the matrix inequality approach combined with the Lyapunov second method. A parameterized characterization of the robust guaranteed cost controllers is given in terms of the feasible solutions to the certain matrix inequalities. A numerical example is given to illustrate the proposed method.

Measurement on Perceived Human Body Joints Discomfort in the Standing Posture (선 자세에서의 인체 관절의 지각 불편도 측정)

  • Kee, Do-Hyung
    • IE interfaces
    • /
    • v.10 no.3
    • /
    • pp.197-208
    • /
    • 1997
  • In workplace design, an ergonomic solution should ensure low postural stress in the operator during his/her work. Stress caused by awkward working postures of the trunk, shoulders and legs can result in fatigue, discomfort, musculo-skeletal disorders and nerve entrapment syndromes. Since discomfort and musculo-skeletal disorders are both related to exposure to biomechanical load on the musculo-skeletal system, minimization of discomfort will contribute to reduction of the risk for musculo-skeletal disorders as well. Therefore, in this study, perceived discomfort on the human body joints was measured in the standing postures using the magnitude estimation in order to have a standardized numerical scale for joint discomfort. Nine healthy graduate students participated voluntarily in the laboratory study. The results revealed that perceived discomfort of all the joints increased as the joints deviated from neutral position. Especially, it showed drastic increment on perceived discomfort when deviation from neutral position in each human body joint increased from 75% to 100%. in terms of relative range of motion(R0M). On the basis of these experimental results, a preliminary ranking for assessment of stressfulness of non-neutral postures around the human body joints was suggested.

  • PDF