• Title/Summary/Keyword: Needle-free Injection

Search Result 19, Processing Time 0.021 seconds

Frequency of Lesions on Injection Site by Vaccination Using Needle-Free Injection (무침주사기를 이용한 구제역 백신 접종과 이상육 발생)

  • Lee, S.H.;Choe, J.;Koo, H.J.;Chae, C.J.;Park, J.K.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.23 no.1
    • /
    • pp.27-30
    • /
    • 2021
  • Vaccination for swine food and mouth disease (FMD) has been using needle injection. Needle injection can cause lesions of injection site on muscle and lymph node, leading to consumer's complain and Korea Pork's image deterioration. Needle-free injections have been developing to solve this issues. The current study performed to evaluate the frequency of muscle and lymph node lesions after vaccination using needle-free injection. Needle-free injection significantly decreased the lesions on the injection site compared with the needle injection(36 vs. 16%, p < 0.05). Based on the result, needle-free injection can enhance the quality of pork and decrease consumer's complains. Further study should perform to validate potential of needle-free injection by investigating antibody formation rate, work efficiency, and economic cost.

Effect of the new needle-free injection system on pain perception and dental anxiety during anesthesia: randomized controlled split-mouth study

  • Melek Belevcikli;Halenur Altan;Osman Demir
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • Backgrounds: Pain management is one of the most important factors affecting the success of pediatric dentistry. Therefore, new needle- and pain-free local anesthesia techniques have been developed in parallel with technological advancements. The purpose of this study is to compare the pain perception and dental anxiety levels associated with a needle-free injection system (Comfort-inTM) and the classic needle method during treatment-required infiltration anesthesia in children. Methods: This randomized controlled crossover split-mouth clinical study included 94 children who required dental treatment with local anesthesia using a dental needle or needle-free injection system for the bilateral primary molars. The Wong-Baker Scale (WBS) was used to measure pain perception at different times, and the Modified Child Dental Anxiety Scale (MCDAS) was used to measure the anxiety level of the child. A statistical software package was used to process the data. Statistical significance was set at P < 0.05. Results: There was no significant difference between the needle-free injection system and dental needle method during the induction stage for filling and pulpotomy (P > 0.05). "Pain on postoperative 1st day" was similar in both types of anesthesia (P = 0.750). Conclusions: The needle-free injection system was as effective as the dental needle method. The Comfort-inTM system was an acceptable alternative for patients during the postoperative period. Understanding how pain management may be provided during local anesthesia administration and a child's fear and anxiety regarding the dentist may lead to better dental compliance.

Experimental Investigation on Key Parameters in Air-powered Needle-free Injection System for Skin Treatment (피부 치료를 위한 공압식 무침 주사 시스템의 주요 인자에 관한 실험적 연구)

  • Kim, Jung Kyung;Mohizin, Abdul;Lee, Seung Ku
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.42-47
    • /
    • 2018
  • A needle-free injector is one of the new non-invasive players in impregnating the biological barriers. It is considered as the next phase in drug delivery and therapeutic applications. One of the major fields of application is in skin remodeling procedures. Although many studies were carried out in understanding the principle in the needle-free injection procedure, fewer studies were done with the aim of therapeutic applications. In the present study, we tried to identify key parameters that affect the jet divergence and peak stagnation pressure on the skin surface in a conventional needle-free injector for skin treatment. A summary of the working principle and effect of the key parameters are presented.

Reduction in Lesion Incidence in Pork Carcass Using Transdermal Needle-free Injection of Foot-and-Mouth Disease Vaccine

  • Ko, Eun Young;Cho, Jaesung;Cho, Jin Ho;Jo, Kyung;Lee, Seung Hwan;Chung, Yoon Ji;Jung, Samooel
    • Food Science of Animal Resources
    • /
    • v.38 no.6
    • /
    • pp.1155-1159
    • /
    • 2018
  • Foot-and-mouth disease (FMD) is an infectious disease affecting pigs. The control of FMD in swine husbandry is very important because its outbreak results in a vast economic loss. FMD vaccination has effectively controlled FMD; however, it results in economic loss associated with the incidence of lesions in the pork meat at the injection site. The objective of this study was to investigate the effects of transdermal needle-free injection (NFI) of the FMD vaccine on the incidence of lesions at the injection site. Pigs (n=493) in the control group were vaccinated with the FMD vaccine using a commercial syringe needle, while 492 pigs in the transdermal NFI group received the FMD vaccine using a needle-free gas-powered jet injector. After the slaughter of the pigs, the incidence of lesions at the injection site of all pigs was checked by plant workers. The result of this study showed that the incidence of lesions in the pork ham from pigs vaccinated with NFI was 14.82% lower than that in control pigs (p<0.01). In addition, lesions generated in the NFI group were found just in the subcutaneous tissue. Therefore, the incidence of lesions at the injection site in pork from pigs vaccinated with the FMD vaccine can be effectively reduced by using transdermal NFI rather than a conventional syringe needle.

Alternative practices of achieving anaesthesia for dental procedures: a review

  • Angelo, Zavattini;Polyvios, Charalambous
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.2
    • /
    • pp.79-88
    • /
    • 2018
  • Managing pain and anxiety in patients has always been an essential part of dentistry. To prevent pain, dentists administer local anaesthesia (LA) via a needle injection. Unfortunately, anxiety and fear that arise prior to and/or during injection remains a barrier for many children and adults from receiving dental treatment. There is a constant search for techniques to alleviate the invasive and painful nature of the needle injection. In recent years, researchers have developed alternative methods which enable dental anaesthesia to be less invasive and more patient-friendly. The aim of this review is to highlight the procedures and devices available which may replace the conventional needle-administered local anaesthesia. The most known alternative methods in providing anaesthesia in dentistry are: topical anaesthesia, electronic dental anaesthesia, jet-injectors, iontophoresis, and computerized control local anaesthesia delivery systems. Even though these procedures are well accepted by patients to date, it is the authors' opinion that the effectiveness practicality of such techniques in general dentistry is not without limitations.

Development and application of non-invasive drug delivery systems utilizing pulse power, and its application to mouse models (펄스파워를 적용한 비침습 약물 전달기 개발 및 마우스 모델로의 적용)

  • Hwi-Chan Ham;Kyu-Sik Kim;Ji-Hwan Lee;Hyung-Jin Choi;Do-Nyun Kim;Jai-Ick Yoh
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • Some drugs can offer far better medical effectiveness as it is injected through the intradermal layer of the skin, known as a needle-free injection. However, conventional needle-free devices might deliver a relatively large amount of drug in a just single spot of skin, splitting open the tissue layer structure, which might cause bruising and bleeding. By injecting the small volume with a fast repetition rate in a large surface area of skin, the patient may get much fewer injuries and pain. To achieve that specification, the driving force must be instantaneous and short-pulsed. Such a form of an injection device has been developed but the efficacy of those devices has been rarely examined. Therefore, this study developed the laser-induced microjet device that ejects microjet whose speed is ~310 m/s, during the 400~800 ㎲ of pulse time. The device can eject ~1 µL of the drug at the rate at which each shot repeated 10 shots per second. Using this specification, we evaluated the efficacy of drug injection onto mouse models. After injecting the insulin solution into the mouse model, the blood insulin level is detected, resulting in 20 % of blood insulin level with the ordinary needle syringe injection method.

Effects of Foot-and-mouth Disease Vaccination Location and Injection Device on the Incidence of Site Lesions in Pork

  • Ko, Eun Young;Jung, Samooel;Jeong, Hyun Kyu;Han, Jeong Hee;Son, Jung Ho
    • Food Science of Animal Resources
    • /
    • v.38 no.3
    • /
    • pp.498-505
    • /
    • 2018
  • This study was aimed to investigate the effects of the type O foot-and-mouse disease vaccine (FMDV) on the incidence of abnormal meat such as granuloma or abscess formation at the injection site in pork and its associated economic losses. At 56 d of age, piglets were inoculated with FMDV by one of three administration routes: N-Neck (a conventional needle-syringe injection into the neck), N-Ham (a conventional needle-syringe injection into the ham), and Non-Neck (injection with a needle-free device into the neck). The injection sites were visually examined for the presence of a granuloma or abscess, and the incidence rate of abnormal meat was calculated. The gross weight of the portion of the pork carcasses condemned because of granuloma or abscess formation was measured and multiplied by the weekly sales price to calculate the total economic losses. After implementation of FMDV, the economic losses were approximately six times higher than before implementation. Granuloma or abscess formation was significantly higher in the N-Neck and Non-Neck groups, in which the vaccine was inoculated into the neck area, than in the N-Ham group (N-Neck and N-Ham vs Non-Neck, p<0.05). These results suggest that the incidence of lesions could be reduced if the ham route was used for vaccination.

Comparative Study of Therapeutic Effect of Needle-free Bee Venom Aqua-acupuncture (BVA) into Zusanli (ST36) in the Rat Formalin Test (포르말린으로 유도된 통증 유발 쥐에서 무침주입기를 이용한 봉독약침의 진통효과)

  • Jeong, In-Jae;Hahm, Dae-Hyun;Jung, Wu-Byung;Han, Ji-Hee;Chae, Youn-Byoung;Lim, Hyoung-Soo;Lee, Hye-Jung;Kang, Sung-Keel;Kim, Jang-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.365-371
    • /
    • 2006
  • Bee Venom aqua-acupuncture (BVA) simultaneously exerts pharmacological effects of biologically active compounds, existed in the whole bee venom, and medicinal effect of the stimulation of acupuncture points. BVA has been considered as a promising therapeutic method for treating various chronic diseases, mainly accompanying severe pain and inflammation. As a painless injection device, jet injectors have been commercially marketed for various clinical applications including insulin injection and vaccination. Among them, a pressure-driven jet injector system could be used for intradermal delivery of a variety of drugs. The aim of this study was to investigate the analgesic effects of the BVA using a needle-free injector (Biojector $2000^{\circledR}$, Bioject Inc., OR, USA), compared to the conventional BV aqua-acupuncture using a typical syringe. Adult Sprague-Dawley rats were injected with bee venom $(0.08mg/kg,\;50{\mu}l)$ using Biojector $2000^{\circledR}$ (BVA-B) or a syringe (BVA-5) into the Zusanli (ST36) acupoint, 30 minutes before plantar injection of 2% formalin. It was found that BVA-B-, or BVA-5-treated rats, compared to controls, exhibited significantly less licking behavior during the late phase in the rat formalin test, when compared to controls. During early phase, however, those effects were not significant but substantial. The analgesic effect of BVA-B was also compatible with that of the conventional BVA-5. In the immunohistochemical studies, BVA-B significantly suppressed the expression of formalin-evoked c-fos, a biomarker of neuronal activity, in the lumbar dorsal horn of the spinal cord. These results indicated that BVA-B waseffective in the modulation of pain in the rat formalin test, compared to BVA-5. Taken together, the needle-free jet injector system could be substituted for the conventional aqua- acupuncture with the advantage of little pain.

The Effect of Bee Venom Therapy on Skin Aging (봉독이 피부 노화에 미치는 영향)

  • Kim, Jin-Myoung;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.2
    • /
    • pp.27-40
    • /
    • 2010
  • Background and Objective : Increasing interest in anti-aging and anti-wrinkling agents for the skin has triggered the recent outflow of researches and studies in this field. This study was designed to investigate the effects of bee venom on skin wrinkling and skin aging by testing the skin wrinkling, skin elasticity, trans-epidermal water loss (TEWL), free radical level, anti-oxidative agent level, and skin tissue after infusion of bee venom on hairless mouse. Materials and Methods : Fifteen hairless mice aged between 36~40 weeks were divided randomly into 3 Group; the Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group. The Bee Venom Syringe Group were injected subcutaneously with bee venom (0.1cc in total) using an insulin syringe on three spots in the lumbar spine (one spot on the center and two spots 1~2cm to the side bilaterally). The Bee Venom Needle Group were pricked with bee venom-smeared acupuncture needles on three longitudinal spots in the lumbar spine each 1cm apart, after which the needles were removed 10 minutes later. The Control Group did not receive any form of intervention. All procedures took place thrice a week for four weeks, during which the mice were allowed free access to water and fodder. The mice were measured and compared in the weight, skin wrinkling scale, skin elasticity, and TEWL before and after the experiment. After the experiment, blood samples were taken to measure the free radical and anti-oxidative agent level, and the skin tissue was sliced for examination. Data was analyzed using the SPSS program (ver 12.0). The ANOVA analysis was used to compare and contrast the three groups, and t-test for paired samples was used to evaluate skin-wrinkling before and after experiment. The cut-off p-value of significance was set at p<0.05. Results : 1. Administration of bee venom did not cause serious weight loss or gain. 2. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed a decrease in skin wrinkling scale after intervention. Especially, the Bee Venom Syringe Group showed a significant decrease (p<0.05). 3. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed an increase in skin elasticity. Especially, the Bee Venom Syringe Group showed a significant increase (p<0.05). 4. No significant change in TEWL was found in the mice in all the three groups before and after experiment. 5. Free radical level was normal in all 15 mice in all the three groups, and anti-oxidative agent was not significantly different across the three groups. 6. The Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group did not show any significant difference in the thickness of epidermis and dermis, infiltration of inflammatory cells, and skin wrinkling. The epidermis layer was relatively better preserved in the Bee Venom Syringe Group as compared to the Bee Venom Needle Group and the control group. Conclusion : Direct injection of bee venom on the hairless mouse using a syringe was found to improve wrinkling of the skin and increase skin elasticity but did not show effectiveness on skin dryness due to water loss. The bee venom appears to have suppressive effects on skin wrinkling, one of the symptoms of skin aging, through a process independent of suppression of free radicals or increase of anti-oxidative agent.

Development of a painless injector using high speed laser propulsion and its spin-off to medical industry (고속레이저추진원리를 활용한 무통증 주사기의 개발 및 의료산업으로의 Spin-off)

  • Han, Tae-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.326-330
    • /
    • 2010
  • A laser based needle-free liquid drug injection device has been developed. A laser beam is focused inside the liquid contained in the rubber chamber of micro scale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is 125 ${\mu}m$ and the injected microjet reaches an average velocity of 264 m/s. This device adds the time-varying feature of microjet to the current state of liquid injection for drug delivery.

  • PDF