• Title/Summary/Keyword: NFPA codes

Search Result 10, Processing Time 0.018 seconds

Globalization of Korean Electrical Installations Standards and Codes Based on Comparison of IEC 60364 with NFPA

  • Ki, Chung-Young;Ro, Kwak-Hee;Seop, Shin-Hyo;Joo, Nam-Taik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.118-125
    • /
    • 2001
  • Most of the laws and standards relevant to technology in Korea bear a resemblance to those in Japan. Electricity was not introduced to Korea until Lighting ceremony in Kyong-Bok palace observed in 1887. Since Korea was annexed to Japan in 1910 and our public works were under Japan control we have applied Japanese laws and regulations made by Chosun government-general. Independently from Japan the power electricity accepted power plants of USA, codes of NESC, ASME / ANSI, NEMA. Our generation and distribution system takes American style while our consumer side takes Japanese style. As global trade system was transferred GATT into WTO, the harmonization of technological standards, certification construction testing in the trend of world. This paper is based on WTO / TBT agreement coming in effect after 12th, April, 1979. For Korea the distribution system has a strong resemblance to American system so that unconvertible because IEC 60364 originated from Europe while NEC originated from USA. This papers deals with the fundamental elements of electrical safety system with comparing IEC 60364 with NEC. This paper considers how engineers should apply NFPA 70(NEC) and IEC based on the comparison of NEC to IEC in relation to electrical installations.

  • PDF

Globalization of Korean Electrical Installations Standards and Codes Based on Comparison of IEC 60364 with NFPA 70(NEC)

  • Ki, Chung-Young;Ro, Kwak-Hee;Seop, Shin-Hyo;Joo, Nam-Taik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.280-287
    • /
    • 2002
  • Most Technological laws of Korea are almost identical to those of Japan. Electricity was not introduced to Korea until lighting ceremony in Kyong-Bok palace observed in 1887. Since Korea was annexed to Japan in 1910, Korea have applied Japanese law and regulations made by Chosun government-general. And public works were under Japan control. Korea accepted adopted the power plants of America, codes of NESC, ASME / ANSI, MEMA while Japan accepted or adopted only IEC. Our generation distribution system takes American style while our consumer side takes Japanese style. As global trade system was transferred GATT into WTO, the technological standards, certification, construction and testing are in harmony internationally. The WTO / TBT agreement came in effect after 12th, April, 1979. The sections in the agreement require the members to exchange their own standards and codes for the harmonized ones by degree. The Korean distribution system has a strong resemblance to American system so that the internal engineers are confused in application of the relevant standards. IEC60364 and NEC are technologically similar but practically unconvertible because both have their different originality, that is to say Europe and USA. This paper deals with the fundamental elements of electrical safety system on review of IEC 60364 and NEC. This paper considers how engineers should apply IEC60364 and NFPA 70(NEC) based on all-the-way review of them.

  • PDF

A Study on the Revision of the National Fire Safety Codes of Sprinkler System (스프링클러설비 화재안전기준 개정에 대한 고찰)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.32-37
    • /
    • 2013
  • This paper suggested to revise unreasonable national fire safety codes of sprinkler system. Also proposed to modify the definition of "the gridded sprinkler system" and to add "the feed main" in terms of the definition of the pipes. In order to operate the regulations of discharge pressure of the sprinkler head efficiently, this paper checked the minimum criteria of pressure and flow for the pipe schedule sprinkler system of NFPA 13 and suggested to establish the similar minimum demand criteria. It proposed to be amended properly the pressure calculation formular in the pressure tank system and to use the correct K value due to change in pressure unit and to use the [bar] as a unit of pressure for the sake of using the existing K-factor etc.

Review of Code Provisions on Seismic Design of Fire Protection System (소방설비 내진설계에 관한 각국 기준 비교 연구)

  • Lee, Hyun-Jin;Shin, Yi-Chul;Lee, Jae-Young;Seo, Dong-Goo;Han, Byung-Chan;Kim, Jae-Hwan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.238-241
    • /
    • 2008
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean code. It is noted that all the codes excepted to korean code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in korean code is also presented.

  • PDF

A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities (의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

The Study on the Necessity of Seismic Design for Fire Protection System and the Establishment of Standard (소방시설 내진설계의 필요성과 기준정비에 관한 연구)

  • Shin, Yi-Chul;Han, Byung-Chan;Park, Sun-Gyu;Lee, Hyun-Jin;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.6-12
    • /
    • 2009
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean Code. It is noted that all the codes excepted to Korean Code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in Korean Code is also presented.

A Study on Evaluation Methods for the Fire-retardant Performance of Hanok Components (건축 마감재의 화재안전기준 비교분석을 통한 한옥 부재의 난연성능 평가기준 연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2011
  • In this study, standards and test methods for building materials of domestic and foreign countries were compared and analyzed to propose evaluation methods for the fire-retardant performance of HANOK components (Traditional house). IBC and NFPA codes recently have been adopted in the US, and the properties such as critical heat flux, fire spread index and smoke density are being used as an evaluation reference. In Europe, the unified Euroclass has been adopted and the surface flammability, prototype fire test or cone calorimeter test are conducted for the performance test. Japan has the similar system as Korea where the class is classified into 3 grades. We tried to study a quantitative evaluation method of fire retardant performance for the HANOK components based on the analysis results of the several countries' standards and test methods for building materials.

Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis (열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계)

  • Nam, Minseo;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.34-40
    • /
    • 2022
  • Gas cylinder cabinets have risks such as cylinder explosion and scattering of debris when a fire occurs. These risks are likely to cause gas spills and cause secondary damage. In order to reduce damage, it is very important to secure the fire resistance performance of the gas cylinder cabinet. In foreign countries, NFPA codes in the United States and EN-14470-2 in Europe stipulate fire resistance test standards for gas cylinder cabinets to protect internal cylinders for a certain period of time in a situation where gas cylinder cabinets are exposed to flames. However, in Korea, only internal pressure performance and airtight performance standards are specified, and the target is limited to piping, and research and regulations for the fire resistance performance of gas cylinder cabinets are insufficient compared to overseas. Therefore, in this study, finite element analysis was used to establish fire resistance standards for domestic gas cylinder cabinets. In the event of a fire, optimal conditions are derived in terms of structure and material.

Study on the Prioritization of Management for Each Toxic Chemical Substance in Ansan Smart Hub. (안산스마트허브 유해화학물질별 관리우선순위 선정에 관한 연구)

  • Choi, Bong Seok;Sa, Jae-Hwan;Kim, Min Wook;Jeon, Eui Chan
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • With a rapid growth of domestic industry in korea, now about 25,000 kinds of chemicals are being distributed, and it has been known that just about 15% of them has toxic substances. Recently, South Koreans have an anxiety about the stability and accidents of chemicals because chemical accidents like Gumi hydrofluoric acid accident have occurred. The U.S. has adopted the systems like EPCRA (Emergency Planning and Community Right-to-Know Act), TRI (Toxic Release Inventory) and TSCA (Toxic Substances Control Act), and is also managing the hazardous chemicals by providing the information about them to its people and site workers. Japan's Ministry of Health, Labor and Welfare also has adopted J-CHECK system and is implementing it to let Japanese people know the information of safety of chemicals about REACH. However, the Korean government has a difficult situation to mediate the different idea with the Korean industry to make lower statute of Pre-legislation registration & evaluation of chemicals that will be implemented and Chemical Material Control Association that is being implemented. Especially city and country areas located in the industrial areas need political improvement focusing on vulnerable area through the check about current situation of hazardous chemicals of jurisdiction and management method, but the information about the management situation of small scale work places is insufficient. Therefore this study set up the urgent management area in Ansan Smart Hub through NFPA code according to the types of accident and dander characteristics of each chemical being used in the companies that have less than 50 workers and deal with chemicals located in Ansan Smart Hub in Gyeonggi-do.

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.