• 제목/요약/키워드: NDD-M

검색결과 12건 처리시간 0.023초

환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M (Non Dosimetry Measurements Use for Patients Safety : NDD-M)

  • 길종원;선종률;송월수
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

선질계수에 의한 피부입사선량 계산법 (Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor)

  • 김성철;김종일;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제10권2호
    • /
    • pp.258-267
    • /
    • 2010
  • 방사선피폭에 대한 관심이 높아지면서 X선 검사시에 환자에게 조사되는 피폭선량을 정확히 알고 있다는 것은 환자의 불안을 해소하고 또 방사선사나 의사가 피폭선량 경감의식을 향상시키는 데 중요하지만, 임상에서 측정기를 보유하고 있는 시설은 극소수에 불과하다. 본 연구에서는 bit system 및 NDD-M법의 특징을 살려서 우리나라에 사용되고 있는 진단용 X선장치의 출력선량을 직접 측정하여 도표화 하고, X선 출력선량을 아는 경우 또는 모르는 경우 모두에서 적절히 적용할 수 있게 두 가지 방법을 제시하여 실측선량과 비교 실험을 하였다. 그 결과 bit system 및 NDD-M법보다 정확도가 우수한 결과를 나타내어 임상에서 환자가 받는 선량을 더욱 쉽게 알 수 있게 됨으로 방사선관련 종사자들의 의료피폭에 대한 관심이 더욱 높아지고 의료선량감소에 한층 더 노력하는 계기가 될 것으로 사료된다.

$(Zr-DEHPA)/n-dodecane-HNO_3$ 금속함유 추출 계에 의한 악티나이드(III)및 RE의 공추출 및 상호 분리 (Evaluation of co- and Mutual Weparation for Actinide(III) and RE by a $(Zr-DEHPA)/n-dodecane-HNO_3$ Extraction System)

  • 이일희;임재관;정동용;양한범;김광욱
    • 방사성폐기물학회지
    • /
    • 제5권2호
    • /
    • pp.123-132
    • /
    • 2007
  • 본 연구는 실제 HLW 수준의 다성분 계 모의 용액으로부터 $Zr-DEHPA/NDD-HWO_3$ 금속함유 추출 계에 의한 Am-Cm/RE 원소의 공분리 및 이의 상호분리 연구를 수행하였다. 우선 금속함유 추출제인 Zr-DEHPA를 자체 제조하고, 제 3상 방지 조건 결정과 질산 농도, DEHPA 농도, Zr 함유량 등이 공추출에 미치는 영향을 평가하여 최적 조건으로 (15g/L Zr-1M DEHPA)/NDD-1M $HNO_3$ 추출 계를 설정하였다. 이때 추출률은 Am (81%), Cm (85%), RE 원소 (80% 이상), Mo (98%), Fe (85%), U (98%), Np (73%), 기타 원소 (5% 이하) 등으로 Am-Cm/RE의 공분리 적용성은 양호하나, U, Np, Mo, Fe의 선제거가 필요하고 특히 제 3상 형성 유발 물질인 Zr이 거의 함유되지 않아야 한다. 그리고 공추출된 Am-Cm/RE를 Am-Cm (역추출제 : 0.05M DTPA-1M Lactic acid-pH 3.6)${\rightarrow}RE$ (역추출제 : 5M $HNO_3$) 순으로 상호 분리하여 각각의 분리계수를 평가하였으며 이때 Am은 65.4%, Cm은 63.9% RE 원소(Y 제외)는 85% 이상이 역추출 되었다.

  • PDF

$(TBP-TOA)/n-dodecane-HNO_3$ 추출 계에 의한 Tc, Np, U의 공추출 및 순차분리 평가 (Evaluation of co- and Sequential Separation for Tc, Np and U by a $(TBP-TOA)/n-dodecane-HNO_3$ Extraction System)

  • 이일희;임재관;정동용;양한범;김광욱
    • 방사성폐기물학회지
    • /
    • 제5권2호
    • /
    • pp.133-143
    • /
    • 2007
  • 본 연구에서는 다성분의 모의 HLW 용액으로부터 $(TBP-TOA)/NDD-HNO_3$ 혼합추출 계에 의한 Tc, Np, U의 공분리 및 이의 순차 분리 적용 가능성을 평가하였다. 우선 제 3상 방지 및 TBP, TOA,질산 농도 등이 Tc, Np, U의 공분리에 미치는 영향 등을 고려하여 최적 조건으로 (30% TBP-0.5% TOA)/NDD-1M $HNO_3$ 계를 선정하였다. 이때 추출율은 Tc (81%), Np (85%), U (93%), Am/RE 원소 (9% 이하) Pd (약 8%), 기타 원소 (5% 이하)로 Tc, Np 및 U의 공분리는 매우 우수하였으나, 조업 측면에서 Zr의 선 제거 (약 99 % 이상)가 요구되었다. 그리고 공추출된 Tc, Np 및 U을 Tc (역추출제 : 5 M $HNO_3$)${\rightarrow}Np$ 환원 (역추출제 : 0.1 M AHA)${\rightarrow}U$ (역추출제 : 0.01 M $HNO_3$)의 순으로 순차 분리하여 각각의 분리계수를 평가하였으며, 이때 Tc은 95%, Np은 98%, U은 99%를 회수할 수 있었다.

  • PDF

High tendency to the substantial concern on body shape and eating disorders risk of the students majoring Nutrition or Sport Sciences

  • Nergiz-Unal, Reyhan;Bilgic, Pelin;Yabanci, Nurcan
    • Nutrition Research and Practice
    • /
    • 제8권6호
    • /
    • pp.713-718
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: Studies have indicated that university students majoring in nutrition and dietetics or sport sciences may have more obsessions associated with eating attitudes and body shape perception compared to other disciplines i.e. social sciences. Therefore, this study aimed to assess and compare the risk of eating disorders and body shape perception. MATERIALS/METHODS: Data was collected from 773 undergraduate students at the Departments of Nutrition and Dietetics (NDD) (n = 254), Physical Education and Sports (PESD) (n = 263), and Social Sciences (SOC) (n = 256).A socio-demographic and personal information questionnaire, Eating Attitudes Test (EAT-40), Body Shape Questionnaire (BSQ-34), Perceived Figure Rating Scale (FRS) were applied; and body weights and heights were measured. RESULTS: Mean EAT-40 scores showed that, both male and female students of PESD had the highest scores ($7.4{\pm}11.6$) compared with NDD ($14.3{\pm}8.3$) and SOC ($13.0{\pm}6.2$) (P < 0.05). According to EAT-40 classification, high risk in abnormal eating behavior was more in PESD (10.7%) compared to NDD (2.9%) and SOC (0.4%) students (P < 0.05). Students of PESD, who skipped meal, had higher tendency to the risk of eating disorders (P < 0.05). In parallel, body shape perception was found to be marked with higher scores in NDD ($72.0{\pm}28.7$) and PESD ($71.5{\pm}32.8$) compared with SOC ($64.2{\pm}27.5$) students (P < 0.05). Considering BSQ-34 classification, high concern (moderate and marked) for body shape were more in PESD (7.4 %) compared to NDD (5.2%) and SOC (1.9%) students (P < 0.05). The body size judgement via obtained by the FRS scale were generally correlated with BMI. The Body Mass Index levels were in normal range (Mean BMI: $21.9{\pm}2.8kg/m^2$) and generally consistent with FRS data. CONCLUSIONS: Tendency to the abnormal eating behavior and substantial body shape perception were higher in PESD students who have more concern on body shape and were not well-educated about nutrition. In conclusion, substantial concern on physical appearance might affect eating behavior disorders in PESD students.

입사 표면 선량 계산에 따른 진단용 X-선 촬영시 피폭선량 비교 연구 (Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography)

  • 한재복;최남길;성호진
    • 한국콘텐츠학회논문지
    • /
    • 제11권12호
    • /
    • pp.357-363
    • /
    • 2011
  • 본 연구는 유리 선량계를 이용한 진단용 X선 장치 선량 및 선질의 입사표면선량 값과 선질 계수에 의한 계산 측정법을 바탕으로 비교 평가하여 의료 피폭 선량에 대해 연구하였다. 실제 측정에 의한 ESDs 값이 Mori에 의한 NDD-M 법에서 가장 큰 차이를 보였으며, Edmonds에 의한 계산법이 가장 적은 차이를 보였다. 또한 정류 방식에 따른 실 측정과 선량 계산법 차이는 삼상 정류 방식, 단상 정류 방식, 인버터 방식으로 차이가 적게 나타났다. 본 연구 결과는 향후 진단용 X-선 촬영 장치의 사용에 있어 환자의 피폭 선량을 예측하고 검사 조건을 조절하여 의료 피폭 선량을 절감할 수 있을 것이다.

나노도트선량계를 이용한 입사표면선량의 평가 (An Assessment of Entrance Surface Dose Using the nanoDot Dosimeter)

  • 김종언;임인철;박철우
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.377-381
    • /
    • 2011
  • 이 연구의 목적은 일반방사선촬영에서 입사표면선량에 대하여 나노도트선량계의 측정값과 Non Dosimeter Dosimetry-Method(NDD-M)의 계산값과 비교 평가하는 데 있다. 입사표면선량들의 측정과 계산은 두부(AP), 복부(AP), 골반(AP), 흉추(AP)와 요추(AP)에 대하여 수행하였다. 결과로서, 계산값에 대한 측정값의 상대비들은 각 부위에 대하여 1.5-2.1을 얻었다. 재현성은 변동계수로서 0.035를 얻었다.

X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가 (A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System)

  • 한동균;고신관;선종률;윤석환;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

CO-SEPARATION OF Am AND RARE EARTH ELEMENTS FROM A HIGHLY ACIDIC RADWASTE SOLUTION BY A SOLVENT EXTRACTION WITH (DIMETHYLDIBUTYL TETRADECYLMALONAMIDE-DIHEXYLOCTANAMIDE)/N-DODECANE

  • Lee, Eil-Hee;Lim, Jae-Gwan;Chung, Dong-Yong;Yoo, Jae-Hyung;Kim, kwang-Wook
    • Nuclear Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.319-326
    • /
    • 2009
  • This study was carried out to investigate the high-acidity co-separation of Am and RE from a simulated radwaste solution by a solvent extraction using a mixture of Dimethyldibutyltetradecylmalonamide (DMDBTDMA, as an extractant) and dihexyl octanamide (DHOA, as a phase modifier) diluted with n-dodecane (NDD). All the experiments were conducted as a batch type. First, the environmentally friendly DMDBTDMA and DHOA composed of only CHON atoms were self-synthesized. Then, the conditions for the prevention of a third phase, generated in the organic phase were examined. In addition, the effects of the concentration of nitric acid, DHOA, oxalic acid and $H_2O_2$ on the co-extraction of Am and RE were elucidated. Consequently, the optimum condition of (0.5M DMDBTDMA+0.5M DHOA)/NDD-0.3M $C_2H_2O_4-4.5M$ $HNO_3$ and O/A=2 was obtained through experimental work. Under this condition, the extraction yields were found to be about 80% for Am, more than 70% for RE such as La, Eu, Nd, Ce, etc., 3% for Cs and Sr, 69% for Fe and less than 11% for Mo and Ru. For the co-extraction of Am and RE, Fe should be removed in advance or prevented from a co-extraction with Am by controlling the different extraction rates of Am and Fe. About 95% of the Am and RE in the organic phase were stripped using a 0.5M $HNO_3$.

일반 X-선 촬영에서의 환자피폭선량에 관한 조사연구 (Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;이영배;김철민
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.59-63
    • /
    • 2004
  • IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리 한국 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 선량기준을 따로 개발해야할 필요가 있다. 그래서 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서의 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 설문지를 분석한 결과를 보고한다.

  • PDF