• Title/Summary/Keyword: Multiple Carrier

Search Result 499, Processing Time 0.026 seconds

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

A Case of Cryoglobulinemia-induced Acute Respiratory Distress Syndrome (한냉글로불린혈증 환자에서 발생한 급성호흡곤란증후군 1예)

  • Kim, Byung-Gyu;Shim, Jae-Jeong;Jung, Ki-Hwan;Shin, Jeong-Ho;Lee, Seung-Heon;Kong, Hee-Sang;Kim, Je-Hyeong;Bak, Sang-Myeon;Shin, Chol;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • Cryoglobulinemia is the presence of globulins in the serum that precipitate on exposure to cold temperatures(cryoglobulins). Pulmonary complications of cryoglobulinemia include interstial infiltration, impaired gas exchange, small airway disease and pleurisy. Only one other acute respiratory distress syndrome(ARDS) case has been described in patients with cryoglobulinemia. A 55-years old man was admitted with dyspnea. He had been diagnosed as being a hepatitis B virus antigen carrier 15 years ago. On the first admission, chest radiography showed a bilateral pleural effusion and a patchy infiltration on both lungs. On protein- and immuno-electrophoresis, cryoglobulinemia was confirmed. The patient was treated with corticosteroid and plasmapheresis. Forty-five days after the diagnosis, the patient complained of progressive dyspnea and showed a diffuse bilateral pulmonary infiltration on chest radiography. Despite intensive care with mechanical ventilation, the patient died as consequence of hypoxemia and multiple systemic organ failure. On a pathologic examination of the postmortem lung biopsy, multiple necrotizing vasculitis and increased infiltration of the lymphocytes and monocytes were observed. In conclusion, ARDS developed as a result of pulmonary hemorrhage due to cryoglobulinemia-associated vasculitis.

  • PDF

The Correlation of Levels of Serum Lipid, Homocysteine, and Folate with Volumes of Hippocampus, Amygdala, Corpus Callosum, and Thickness of Entorhinal Cortex in Patients with Amnestic Mild Cognitive Impairment or Dementia of Alzheimer's Type (기억성 경도인지장애 및 알츠하이머 치매 환자에서 해마, 편도체, 뇌들보, 내후각 피질과 혈중 지질, 호모시스테인, 엽산 농도와의 연관성)

  • Lee, Sang Jun;Kim, Tae Hyung;Huh, Lyang;Choi, Seung Eun;Lee, Bong Ju;Kim, Gyung Mee;Lee, Jung Goo;Kim, Hong Dae;Mun, Chi Woong;Kim, Young Hoon
    • Korean Journal of Biological Psychiatry
    • /
    • v.22 no.4
    • /
    • pp.223-232
    • /
    • 2015
  • Objectives In this study, the authors evaluated the correlation between levels of serum lipid, homocysteine, and folate with volumes of hippocampus, amygdala, corpus callosum, and in patients with amnestic mild cognitive impairment (aMCI) or Alzheimer's disease (AD) type. Methods The study recruited patients who visited the dementia clinic of Haeundae Paik Hospital in Korea between March 2010 and June 2014. Among those, patients who had taken the neurocognitive test, brain magnetic resonance imaing, tests for serum lipid, homocysteine, folate, and apolipoprotein E (APOE) genotyping and diagnosed with aMCI or AD were included for analysis. Bilateral hippocampus, entorhinal cortex, amygdala and corpus callosum were selected for region of interest (ROI). The cross-sectional relationships between serum lipid, homocysteine, folate and ROI were assessed by partial correlation analysis and multiple linear regression analysis. Results In patients with aMCI, old age (> 80) and APOE ${\varepsilon}4$ carrier were associated with AD [odds ration (OR) : 12.80 ; 95% confidence interval (CI) : 2.25-72.98 and OR : 4.48 ; 95% CI : 1.58-12.67, respectively]. In patients with aMCI or AD, volumes and thickness of ROI were inversely correlated with levels of serum lipid and homocysteine. In multiple linear regression analyses, higher total cholesterol level was related to lower left, right hippocampus volume and left amygdala volume ; higher low-density lipoprotein cholesterol was related to lower right entorhinal cortex thickness ; higher homocysteine level was related to lower corpus callosum volume. Conclusions Higher serum lipid and homocysteine levels are associated with decreased volume of hippocampus, amygdala, corpus callosum and entorhinal cortex thickness in patients with aMCI or AD. These findings suggest that serum lipid and homocysteine levels are associated with AD as a modifiable risk factor.

Dual Process Linear Protection Switching Method Supporting Node Redundancy (노드 이중화를 위한 이중 프로세스 선형 보호 절체 방법)

  • Kim, Dae-Ub;Kim, Byung Chul;Lee, Jae Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.26-37
    • /
    • 2016
  • The core technologies of the current transport network are OAM and protection switching to meet the sub-50ms protection switching time via a path redundancy when a link or node failure occurs. The transport networks owned by public network operators, central/local governments, and major enterprises are individually configured and managed with service resiliency in each own protected sub-network. When such networks are cascaded, it is also important to provide a node resiliency between two protected sub-networks. However, the linear protection switching in packet transport networks, such as MPLS-TP and Carrier Ethernet, does not define a solution of dual node interconnection. Although Ethernet ring protection switching covers the dual node interconnection scheme, a large amount of duplicated data frames may be flooded when a failure occurs on an adjacent (sub) ring. In this paper, we suggest a dual node interconnection scheme with linear protection switching technology in multiple protected sub-networks. And we investigate how various protected sub-network combinations with a proposed linear or ring protection process impact the service resiliency of multiple protected sub-networks through extensive experiments on link and interconnected node failures.

A Study on TDMG Pulse Performance and Structure for Performance Improvement of UWB system (UWB 시스템의 성능개선을 위한 TDMG 펄스 발생기의 성능과 구조에 관한 연구)

  • Ko, Young-Eun;Bang, Sung-Il
    • The KIPS Transactions:PartC
    • /
    • v.11C no.3
    • /
    • pp.395-400
    • /
    • 2004
  • Being aware of growing needs for wireless communication led to the development of UWB systems, this study proposed an impulse for single band UWB systems which does not count a carrier; analyzed the characteristics and the problems of pulses suggested by the existing poise of the Un system; finally, proposed TDMG(Time Delay Multiple Gaussian) pulse that generates signals of UWB without attenuation of pulse width. The hardware structure of the TDMC pulse for the single band UWB system was modelled after describing the pulse in a mathematical method in an attempt to compare with performances of the existing pulses through computer simulation. The outcome of the test unveiled the fact that each center frequency of the TDMG pulse rose approximately 1GHz, and also each l0dB fractional bandwidth of the TDMG pulse was widened over 1GHz. In the case of derivative, center frequencies of the TDMG pulse rose over 1GHz each. As a consequence, the TDMG pulse appeared to have better quality frequency, satisfying the characteristics of spectrum and the band of frequency recommended by the FCC and decreasing interference with other wireless communication systems.

Growth Temperature Effects of In0.4Al0.6As Buffer Layer on the Luminescence Properties of InGaAs/InAlAs Quantum Well Structures (InGaAs/InAlAs 양자우물구조의 발광특성에 대한 In0.4Al0.6As 버퍼층 성장온도의 영향)

  • Kim, Hee-Yeon;Ryu, Mee-Yi;Lim, J.Y.;Shin, S.H.;Kim, S.Y.;Song, J.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.449-455
    • /
    • 2011
  • The luminescence properties of $In_{0.5}Ga_{0.5}As/In_{0.5}Al_{0.5}As$ multiple quantum wells (MQWs) grown on $In_{0.4}Al_{0.6}As$ buffer layer have been investigated by using photoluminescence (PL) and time-resolved PL measurements. A 1-${\mu}m$-thick $In_{0.4}Al_{0.6}As$ buffer layers were deposited at various temperatures from $320^{\circ}C$ to $580^{\circ}C$ on a 500-nm-thick GaAs layer, and then 1-${\mu}m$-thick $In_{0.5}Al_{0.5}As$ layers were deposited at $480^{\circ}C$, followed by the deposition of the InGaAs/InAlAs MQWs. In order to study the effects of $In_{0.4}Al_{0.6}As$ layer on the optical properties of the MQWs, four different temperature sequences are used for the growth of $In_{0.4}Al_{0.6}As$ buffer layer. The MQWs consist of three $In_{0.5}Al_{0.5}As$ wells with different well thicknesses (2.5-nm, 4.0-nm, and 6.0-nm-thick) and 10-nm-thick $In_{0.5}Al_{0.5}As$ barriers. The PL peaks from 4-nm QW and 6-nm QW were observed. However, for the MQWs on the $In_{0.4}Al_{0.6}As$ layer grown by using the largest growth temperature variation (320-$580^{\circ}C$), the PL spectrum only showed a PL peak from 6-nm QW. The carrier decay times in the 4-nm QW and 6-nm QW were measured from the emission wavelength dependence of PL decay. These results indicated that the growth temperatures of $In_{0.4}Al_{0.6}As$ layer affect the optical properties of the MQWs.

Serum HBsAg and Anti-HBs Positive Rate among a City Health Center Visitors (일개 도시 보건소 이용자들의 혈청 HBsAg 및 Anti-HBs 양성률)

  • Shin, Mal-Sook;Hwang, Tae-Yoon;Kim, Chang-Yoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.508-517
    • /
    • 1997
  • Hepatitis B virus(HBV) infection is one of the major health problems in Korea and HBsAg positive rate was known to be about $5\sim15%$ in general population. This study was conducted to identify the positive rates of serum HBsAg and anti-HBs among community population regarded as having hish HBV vaccination rate than in previous decade, using EIA(Enzyme immunoassay) method, in Seo-Gu, Taegu, Korea. The study subjects were 1,160 who visited Seo-Gu Health Center for check-up serologic markers of hepatitis 3. The data were obtained from the serologic test for hepatitis markers and questionnaire survey was conducted to obtain the general characteristics, vaccination history, past history of hepatitis and other liver disease, and exposure history to risk factors of hepatitis of the study subjects. The positive rates of HBsAg and anti-HBs were 5.2% and 62.4% respectively. The positive rates of HBsAg for male and female were 6.6% and 4.3% respectively. The age was divided into two groups as group I (less than 15 years old), group II (more than 16 years old) according to the hypothesis that these two groups might be different in HBV vaccination rate. HBV vaccination rates for group I and II were 83.1% and 52.3%. The positive rates of HBsAg for group I and II were 2.6% and 6.5%. The positive rates of HBsAg for the vaccinated people of the group I and II were 2.2% and 3.5%, the positive rates of anti-HBs for the vaccinated people of the group I and II were 70.1% and 71.1% respectively. The most significant factor in positive rate of HBsAg was 'hepatitis carrier in family'. Multiple logistic regression analysis revealed that 'hepatitis history' and 'hepatitis carrier in family' were significant variables for positivity of HBsAg, and 'hepatitis B vaccination' was only a significant variable for positivity of anti-HBs.

  • PDF

Characterization of Optical Properties of Light-Emitting Diodes Grown on Si (111) Substrate with Different Quantum Well Numbers and Thicknesses

  • Jang, Min-Ho;Go, Yeong-Ho;Go, Seok-Min;Yu, Yang-Seok;Kim, Jun-Yeon;Tak, Yeong-Jo;Park, Yeong-Su;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.313-313
    • /
    • 2012
  • In recent years there have been many studies of InGaN/GaN based light emitting diodes (LEDs) in order to progress the performance of luminescence. Many previous literatures showed the performance of LEDs by changing the LED structures and substrates. However, the studies carried out by the researchers so far were very complicated and sometimes difficult to apply in practice. Therefore, we propose one simple method of changing the thickness and the numbers of multiple quantum wells (MQWs) in order to optimize their effects. In our research, we investigated electrical and optical properties by changing the well thickness and the number of quantum well (QW) pair in LED structures by growing the structure -inch Si (111) wafer. We defined the samples from LED_1 to LED_3 according to MQW structure. Samples LED_1, LED_2 and LED_3 consist of 5-pair InGaN/GaN (3.5 nm/ 4.5 nm), 5-pair InGaN/GaN (3 nm/4.5 nm) and 7-pair InGaN/GaN (3.5 nm/4.5 nm), respectively. We characterized electrical and optical properties by using electroluminescence (EL) measurement. Also, Efficiency droop was analyzed by calculating external quantum efficiency (EQE) with varying injection current. The EL spectra of three samples show different emission wavelength peaks, FWHM and the blueshift of wavelength caused by screening the internal electric field because of the effect of different MQW structure. The results of optical properties show that the LED_2 sample reduce the internal electric field in QW than LED_1 from EL spectra. the increase in the number of QW pairs reduces the strain and increase the In composition in MQW. And, the points of efficiency droop's peak show different trend from LED_1 to LED_3. It is related with the carrier density in active region. Thus, from the results of experiments, we are able to achieve high performance LEDs and a reduction of efficiency droop and emission wavelength blueshift by optimizing MQWs structure.

  • PDF

Growth Characteristics of an Attenuated Japanese Encephalitis Virus in a Monkey Kidney Cell (Vero) (베로 세포에 적응된 약독화 일본뇌염바이러스의 성장 특성)

  • 홍선표;정용주;문상범;신영철;이성희;김수옥
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.231-237
    • /
    • 1998
  • An attenuated Japanese encephalitis virus (JEV) clone SA-14-14-2(Vero) was obtained through successive adaptation of a primary cell adapted strain, SA-14-14-2(PDK) to Vero cell, a continuous line of monkey kidney cells. The virus titer reached above the 107 plaque forming unit (pfu) per mL of culture supernatant with 3 passages in Vero cells and was maintained close to this level in the further passages. The optimum temperature for the virus growth was $35^{\circ}C$. Growth pattern of the virus indicated that optimum time for the virus harvest is 4 days post infection and the virus accomplished rapid initial propagation even in medium containing no serum supplement. The roller bottle (RB) system and the spinner flask (SF) system using micro-carrier (Cytodex-1) for the JEV cultivation were explored. When RB, SF, and T-flask culture system were compared, there was no significant difference in virus yield. Furthermore, the results indicated that virus could be harvested multiple times from 3 days to 9 days post infection; neither severe cytopathic effect (CPE) in the infected cells nor the decrease in the titer was observed on duration of 9 days.

  • PDF

A Study on Calculation of Protection Ratio for Frequency Coordination in Microwave Relay System Networks (M/W 중계 시스템 망의 주파수 조정을 위한 보호비 계산에 대한 연구)

  • Suh Kyoung-Whoan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.139-147
    • /
    • 2006
  • This paper suggests an efficient method of protection ratio calculation and shows some results applicable to frequency coordination in microwave(M/W) relay system networks, and the net filter discrimination(NFD) associated with Tx spectrum mask and overall Rx filter characteristics has been examined to obtain the adjacent channel protection ratio. The protection ratio comprises several factors such as C/N of modulation scheme, noise-to-interference ratio, multiple interference allowance, fade margins of multi-path and rain attenuation, and NFD. According to computed results for 6.7 GHz, 64-QAM, and 60 km at BER $10^{-6}$, fade margin and co-channel protection ratio are 41.1 and 75.2 dB, respectively. NFD for channel bandwidth of 40 MHz reveals 28.9 dB at the first adjacent channel, which results in adjacent channel protection ratio of 46.3 dB. In addition, NFD and protection ratio for different systems with channel bandwidth 20 and 40 MHz have been investigated to be used for actual M/W networks. The proposed method provides some merits of an easy calculation, systematic extension, and applying the same concept to frequency coordination in millimeter wave relay system networks.