• 제목/요약/키워드: Multimedia Information System

검색결과 3,341건 처리시간 0.097초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

비디오 통신 시스템의 실시간 비디오 품질 측정 방법 (Real-Time Video Quality Assessment of Video Communication Systems)

  • 김병용;이선오;정광수;심동규;이수연
    • 대한전자공학회논문지SP
    • /
    • 제46권3호
    • /
    • pp.75-88
    • /
    • 2009
  • 본 논문에서는 실시간 멀티미디어 스트림 서비스에서 발생하는 비디오 품질 저하 요인에 따른 비디오 품질 측정 방법을 제안한다. 비디오 품질 저하에는 대표적으로 비디오 압축과 네트워크의 상태에 의해 발생한다. 본 논문에서는 비디오 압축에 의하여 생기는 화질 저하를 측정하기 위하여 공간 도메인에서 블록킹 왜곡에 대한 정도를 측정하는 방법을 제안한다. 제안하는 블록 경계 강도는 $8{\times}8$ 블록 경계에서 픽셀간의 변화와 경계를 제외한 주변영역에서 픽셀 사이의 변화에 대한 비율로 나타내었다. 반면, 움직임이 부자연스러운 동영상은 지터 및 지연 요소와 같은 네트워크 전송능력의 악화로 인해 비디오 품질 저하가 나타난다. 본 논문에서 제안하는 시간적 저키니스는 연속된 프레임의 대응되는 픽셀간의 밝기 값 차이에 대한 평균과 현재 프레임과 이전 프레임의 재생시간 간격의 평균 및 분산을 이용하는 방법을 제안하였다. 또한, 본 논문에서는 비디오 압축에 의한 품질 측정 방법인 블록 경계 강도와 네트워크에 의한 품질 측정 방법인 시간적 저키니스를 통합하여 비디오의 종합적 품질을 평가하는 Perceptual Video Quality Metric (PVQM)을 제안한다. 제안한 알고리즘의 성능을 평가하기 위하여, 사람이 직접 비디오 품질을 평가하는 Difference of Mean Opinion Score (DMOS)와 제안한 알고리즘을 비교 평가하였다. 그 결과 제안한 PVQM의 결과와 인간 시각에 의하여 평가된 DMOS가 근사함을 확인하였다.

미디어테크놀로지의 발전에 따른 시각언어와 시각테크놀로지의 고찰 (An Observation of the Visual Language and the Visual Technology according to the Media Technology)

  • 신청우
    • 디자인학연구
    • /
    • 제17권2호
    • /
    • pp.15-22
    • /
    • 2004
  • 현재의 복잡한 시각문화는 디지털 기술의 발전에 따라 이미지, 그래픽, 사진, 영화, 텔레비전 등의 영상에 따른 광범위하게 확대된 시각 세계이며, 사운드와 문자까지를 삽입하여 의미 내용을 전달하기 때문에 일반적인 언어나 문자를 넘어 정보를 전달하고 커뮤니케이션 하는 멀티미디어 적 성격을 갖는다고 할 수 있다. 이 때의 다양한 이미지들을 보는 시각은 언어와 불가분 하게 연결되며, 이미지와 시각의 상상적 질서가 문화적, 역사적으로 특정한 방식으로 구성된다고 할 수 있다. 언어는 그 시대의 사회, 문화, 역사에 따라 다르기 때문에 시각적 경험이 부분적으로라도 언어적으로 매개된다면 시각적 경험이 보편성을 갖기는 어려운 것이다. 따라서 시각 체계들간의 사회 문화적 차이를 형성하고 규정하는데 에는 언어적 질서의 역할이 크다고 할 수 있다. 이러한 시각 언어와 함께 역사적으로 다양한 시각적, 광학적 장치들 또한 많은 영향을 끼쳤는데 이 시각적 테크놀로지들은 가시적 세계 속에서 주체와 주체의 가시적인 대상들과 관계 맺는 방식을 결정하는 구체적인 물질적 실천체인 것이다. 시각언어는 이렇게 이미지들의 표상이라는 차원과 일련의 역사적인 물질적, 제도적 실천들로의 시각테크놀로지라는 차원이 결합된 것이며, 이것이 하나의 시각체제 내에서의 대상 세계를 보는 사회적인 시각 양식을 결정하였다. 따라서 본 연구는 미디어테크놀로지의 발전에 따라 변화된 개념이나 특성들에 따라 시각언어를 사회적이고 역사적인 성격을 가진 것으로 이해하고 표상의 차원으로서의 시각언어와 제도적이고 물질적인 실천으로서의 시각 테크놀로지의 차원에서 설명했다. 결국 시각 테크놀로지는 그 기능과 시각 양식에 대한 영향은 그것의 기술적 요소만으로는 설명할 수 없으며, 그것과 결부된 담론적 실천들과 물질적 제도적 실천과 분리될 수 없다. 특정 테크놀로지의 기술적 요소가 담고 있는 가능성 역시 그대로 실현되는 것이 아니라 항상 사회적 맥락에 의해 그 효과가 매개되고 제약되면서 실현된다고 할 수 있다.

  • PDF

운전 중 TV시청이 운전행동에 미치는 영향 (The Effects of in Vehicle Watching TV on Driver Behavior)

  • 신용균;임평남;강수철;류준범
    • 대한교통학회지
    • /
    • 제24권3호
    • /
    • pp.103-112
    • /
    • 2006
  • 최근 IT 기술의 비약적인 발전으로 위성 및 지상파 DMB 서비스가 본격적으로 시작되면서 운전 중 TV를 시청하거나 문자나 동영상으로 제공되는 교통정보를 시청하기 위해 차량 내 TV를 설치하는 사례가 급속하게 증가하고 있다. 그러나 운전중 TV시청은 운전중 음식섭취, 라디오 조작, 휴대폰 사용 등과 유사하게 운전자의 시지각 및 인지적 주의를 분산시켜 안전운전에 방해를 초래할 것이다. 하지만 이와 관련한 국내외의 실증적인 연구가 부족할 뿐만 아니라 운전행동에 있어서 구체적으로 어떻게 영향을 주는 지도 밝혀지지 않았다 따라서 본 연구에서는 국내 운전자들을 대상으로 운전 중 TV 시청에 대한 의식조사를 하였을 뿐만 아니라 차량시뮬레이터를 통한 실험연구를 실시하였다 특히 실험연구에서는 실험참여자들을 두 집단(즉, 운전 중 TV를 시청하는 집단 대 TV를 시청하지 않는 집단)으로 구분하여 TV시청이 운전행동에 미치는 영향을 비교 ·분석하였다. 결과를 살펴보면, 운전 중 TV를 시청하는 집단이 시청하지 않는 집단에 비해서 상대적으로 시각적 주의분포의 폭이 좁고 주행안정성이 떨어졌으며 가속 및 감속 페달 조작을 급하게 하는 것으로 나타났다. 마지막으로 본 연구의 제한점 및 함의에 대하여 논의하였다.

이기종 무선망에서의 다양한 트래픽 환경이 고려된 에너지 효율적인 수직적 핸드오프 기법에 대한 연구 (Power Aware Vertical Handoff Algorithm for Multi-Traffic Environment in Heterogeneous Networks)

  • 서성훈;이승찬;송주석
    • 정보처리학회논문지B
    • /
    • 제12B권6호
    • /
    • pp.679-684
    • /
    • 2005
  • 현재 사용되고 있는 대표적인 무선 네트워크 접속 기술들로는 높은 이동성을 지원하는 휴대 전화망인 WWAN(Wireless Wide Area Networks), 높은 대역폭을 지원하는 WLAN(Wireless Local Area Networks), 그리고 방송 및 데이터를 수신할 수 있는 WDMB(Wireless Digital Multimedia Broadcasting) 등을 들 수 있다. 그러나 각각의 기술들은 각각 이동성 및 데이터 전송률, 그리고 데이터의 방향성 등의 한계를 내포하고 있다. 이러한 제약점을 극복하기 위해, 서로 다른 접속 기술을 상황에 따라 전환하여, 현재 서비스 받고 있는 데이터 접속을 끊김없이 연결해 주어야하는 수직적 핸드오프(Vertical Handoff) 기법에 대한 연구가 활발히 진행 중이다. 본 논문에서는 WWAN 인터페이스를 기반으로, 단말에 장착되어 있는 다른 인터페이스들(WLAN과 WDMB)에 대한 에너지 소모를 최소화하여 전체 시스템의 생명시간(Life time)을 최대화하는 인터페이스 선택 알고리즘과 망구조를 제안한다. 또한 다양한 서비스에 대한 트래픽을 분석하여 망단에 존재하는 사용자 버퍼를 관리하고 이를 수직적 핸드오프의 기준으로 활용하여 기존 방식들에 비교하여 전체적 에너지 소모가 기존 기법 대비 각각 $75\%$(WDMB 우선), $34\%$(WLAN 우선) 절감됨을 보인다.

DMB 서비스를 위한 DCT 기반 MPEG-2/H.264 비디오 트랜스코더 시스템 구조 (DCT-domain MPEG-2/H.264 Video Transcoder System Architecture for DMB Services)

  • 이주경;권순영;박성호;김영주;정기동
    • 정보처리학회논문지B
    • /
    • 제12B권6호
    • /
    • pp.637-646
    • /
    • 2005
  • DMB 서비스를 위해 제공되는 대부분의 비디오 컨텐츠는 MPEG-2 규격으로 압축된 채 제공되므로 실제 서비스를 위해서 H.264 규격으로 트랜스코딩을 수행해야 한다. 현재 사용되는 트랜스코딩 방식은 MPEG-2 비트열(bit-stream)의 디코딩과 H.264 규격으로의 인코딩 과정을 연속적으로 수행하는 픽셀 기반 직렬 구조형 (CPDT, Cascaded Pixel-Domain Transcoding Architecture)이다. 이 방식은 두 표준의 소스 코드를 수정 없이 사용할 수 있으므로 구현이 용이하지만 변환을 위한 처리 시간이 길고 디코딩과 인코딩을 반복하므로 화질의 열화가 발생 할 수 있다. 본 논문에서는 MPEG-2로 압축된 비디오 비트열을 H.264로 트랜스크딩 할 때 변환 시간을 향상할 수 있는 DCT 기반의 열린 회로형 트랜스코더 구조(DCT-OPEN)와 변환시간은 CPDT와 유사하지만 화질면에서 우수한 DCT 기반 닫힌 회로형 트랜스코더(DCT-CLOSED) 구조를 제안한다. 제안된 구조에서는 CPDT 방식과 달리 압축 과정의 중간 단계인 DCT(Discrete Cosine Transform)를 이용하여 변환을 수행한다. 이때, MPEG-2와 H.264의 DCT 단위와 방법이 상이하므로 [l, 2]에서 제안된 방식을 이용하여 DCT 간의 변환을 수행한다. 제안된 구조의 성능 평가를 위해 MPEG-2 TM5하 H.264 JM8 코덱을 수정하여 다양한 구조를 구현하였으며 실험 결과 DCT-OPEN의 경우 CPDT에 비하여 계산 복잡도에서 우수하지만 PSNR 성능은 낮게 나타났으며 DCT-CLOSED의 경우 계산 복잡도는 높으나 화질에서 우수한 것으로 나타났다.

서울지하철의 저주파소음 특성 (Low Frequency Characteristic of Seoul Subway Noise)

  • 정성수;신수현;김호철;이우섭
    • 대한환경공학회지
    • /
    • 제27권11호
    • /
    • pp.1193-1197
    • /
    • 2005
  • 사람의 귀에 들리지 않는 초저주파음을 비롯하여 200 Hz 이하의 저주파소음은 순환기, 호흡기, 신경, 내분비 등 사람의 생리에 영향을 미치는 것으로 알려져 있다. 이에 몇몇 국가들은 나름대로 저주파소음의 측정법과 평가 기준안을 마련한 상태이다. 본 연구에서는 대중교통 수단인 서울지하철을 대상으로 객차 내와 승강장에서의 저주파소음레벨과 스펙트럼을 조사하였다. 측정결과 객차 내 소음레벨은 지하철 운행속도와 곡선구배 등에 따라 차이는 있었으나, 주파수 $1{\sim}200\;Hz$ 대역에서 $60{\sim}105\;dB$로 나타났다. 특히 8 Hz에서의 소음 피크 값은 객차의 길이에 대한 공명주파수에 해당됨을 알 수 있었다. 승강장에서의 소음은 객차 내 소음보다 상대적으로 소음레벨이 낮게 측정되었는데 이것은 차량 도착 혹은 출발 시의 속력이 운행 시의 속력보다 낮기 때문으로 판단된다. Ochiai의 소음에 의한 인체영향 연구를 고려할 때, 객차 내 소음은 주파수 $20{\sim}80\;Hz$ 구간에서 압박감을 줄 수 있기 때문에 주목할 필요가 있다.

다자간 협업 환경을 위한 UDP 터널링 기반의 멀티캐스트 연결성 솔루션의 구현 (Implementation of UDP-Tunneling Based Multicast Connectivity Solution for Multi-Party Collaborative Environments)

  • 김남곤;김종원
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권3호
    • /
    • pp.153-164
    • /
    • 2007
  • 다자간 분산 협업 시스템인 Access Grid (AG)는 원격지에 존재하는 다수의 사용자들 사이에 멀티미디어 정보를 효율적으로 주고받기 위해 IP 멀티캐스트를 활용한다. 하지만 아직까지 많은 네트워크들이 IP 멀티캐스트를 지원하지 않고 있어, AG 기반의 원격 협업 환경을 실제 활용하는 데 어려움을 겪고 있다. 이러한 IP 멀티캐스트 연결성에 대한 해결책으로 AG 커뮤니티에서는 IP 멀티캐스트 네트워크 내에 릴레이 서버를 두고 이 서버와 UDP 연결을 통해 멀티캐스트 데이타를 전달받는 형태의 멀티캐스트 브리지를 활용하고 있다. 하지만 멀티캐스트 브리지는 각각의 유니캐스트 피어에게 동일한 데이타를 중복해서 전송하기 때문에, 시스템과 네트워크 활용 측면에서 문제를 가지고 있다. 본 논문에서는 AG의 IP 멀티캐스트 연결성 문제에 대한 대안으로 UMTP(UDP multicast tunneling protocol)에 기반한 멀티캐스트 연결성 솔루션을 제안한다. UMTP는 응용 계층의 멀티캐스트 터널링 프로토콜로, 멀티캐스트 네트워크에 존재하는 노드와 멀티캐스트가 불가능한 네트워크에 존재하는 노드를 UDP 터널을 이용해 연결하고, 멀티캐스트 데이타를 캡슐화 하여 전달, 상호 간에 멀티캐스트 연결성을 제공한다. UMTP의 장점들을 취하여 제안된 솔루션은 시스템과 네트워크 활용에 효율성을 높이고, 또한 방화벽 환경에 적용 가능하도록 설계되었다. 본 논문에서는 이러한 설계를 기반으로 AG에 활용 가능한 멀티캐스트 연결성 솔루션인 AG Connector를 구현, 검증한 결과를 보인다.

동적 사설 IP 기반의 다중 홈간 DLNA 미디어 컨텐츠 공유 (Sharing of DLNA Media Contents among Inter-homes based on DHCP or Private IP using Homeserver)

  • 오연주;이훈기;김정태;백의현
    • 정보처리학회논문지C
    • /
    • 제13C권6호
    • /
    • pp.709-716
    • /
    • 2006
  • 최근 들어 홈내에 다양한 AV 미디어 장치 및 컨텐츠들이 증가함에 따라, 이들간의 상호운용성을 제공하는 표준안으로서 DLNA의 호환성 가이드라인이 제안되었다. 그런데, 이 권고안에서는 하나의 디지털홈 내부에서의 네트워크 및 미디어 장치 그리고 미디어 컨텐츠들의 상호운용성에 초점을 두었기 때문에, 여러 홈들 간의 멀티미디어 컨텐츠 공유를 위한 검색 및 전송 방법은 제시되어 있지 않다. 또한, 이 권고안에서는 DLNA 장치 발견 및 알림 메시지를 IP멀티캐스트 방식으로 전송하도록 하기 때문에, 현재 인터넷 범위에서는 IP멀티캐스트 서비스가 정상적으로 이루어짐을 보장할 수 없으므로 다른 홈내에 있는 DLNA의 디바이스를 인터넷을 통해 원격에서 검색 및 제어할 수 없다는 제약점이 있다. 따라서, 본 논문에서는 이러한 제약점을 분석하고, 동적 사설 IP기반의 DLNA 장치들로 구성된 여러 홈내에 분포되어 있는 미디어 컨텐츠를 상호 공유할 수 있는 방법으로서, IHM(Inter-Home Media) 프락시 시스템 구조 및 방법에 대해 제안한다. 본 제안된 방법은 자신의 홈 뿐만아니라 다른 홈내에 분산되어 있는 여러 다양한 미디어 컨텐츠들을 공유할 수 있도록 함으로써, 사용자의 위치제약성을 해소할 뿐만 아니라 각각의 홈내 거주자 측면에서는 자신이 부담해야할 컨텐츠 저장소 비용을 절약할 수 있다는 잇점을 가진다.

주행시간 기반 실시간 점대점 최단경로 탐색 알고리즘 (A Real-time Point-to-Point Shortest Path Search Algorithm Based on Traveling Time)

  • 이상운
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.131-140
    • /
    • 2012
  • 네비게이션의 최단 경로 탐색 알고리즘은 일반적으로 Dijkstra 알고리즘에 기반을 두고 있으며, 가중치로 단지 길이 (거리) 만을 고려하고 있다. 거리 기반의 Dijkstra 알고리즘은 출발 노드부터 시작하여 그래프의 모든 노드에 대한 최단 경로를 결정하기 때문에 일반적으로 노드의 수 - 1회를 수행해야 하며, 알고리즘 수행에 많은 메모리가 요구된다. 또한, 거리에만 기반하기 때문에 전방에 차량사고로 인해 병목현상이 발생하였을 때 우회도로를 탐색하는 기능이 없어 항상 동일한 경로만을 탐색한다. 이러한 문제점을 해결하고자, 본 논문은 도로 등급 (고속도로, 국도, 지방도 등)을 고려하지 않고, 속도 기준 (원활, 지체 서행, 정체, 사고 통제 등)도 적용하지 않으며, 단지 도로별 주행시간 (주행속도 ${\times}$ 거리)을 고려한다. 이는 사고, 지체, 공사 등으로 인해 동일한 거리의 도로도 다른 시간이 소요되는 현실성을 반영하여 우회도로를 탐색할 수 있는 장점이 있다. 제안된 알고리즘은 특정 도로에서 사고가 발생하였다고 가정한 경우에도 도로의 통행속도를 실시간으로 반영함으로서 돌발지점을 우회하여 목적지 까지 최단시간 내에 도달 할 수 있음을 증명하였다.