• Title/Summary/Keyword: Motor Performance Test

Search Result 768, Processing Time 0.028 seconds

Computer-based Automated System for Determining the Characteristics, Losses and Efficiency of Separately Excited DC Motors

  • Kaur, Puneet;Chatterji, S.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.440-447
    • /
    • 2012
  • This paper provides essential information on research completed with the aim to develop a 'dc motor test and analysis platform' which can be used to provide dc motor characteristics, calculate losses and efficiency, and also work as a dc motor speed controller. A user can test a given dc motor for these analyses by practicing different conventional methods, but, the concept discussed in this paper, reveals how intelligent integration of all these analyses can be done with a single user friendly automated setup. Integration has been accomplished by a technique that can accommodate all types of dc motors with different ratings at various loading conditions. However, experimentally measured results of a 0.5HP separately excited dc motor using the discussed scheme are presented in the paper. Also, a comparison of the methodology of this system with conventional techniques has also been elaborated on to show the effectiveness of the system.

Characteristics Analysis and Performance Test of the Claw-pole PM Stepping Motor (Claw-pole PM형 스테핑 모터의 특성 해석 및 성능 평가)

  • You, Yong-Min;Oh, Sang-Yeul;Kim, Jick
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.21-23
    • /
    • 2004
  • The claw-pole PM(Permanent Magnet) stepping motor has the advantage of the positioning machine because of a relatively little step angle, facility of control, and detent torque characteristics. Although the research about this motor has been progressed, it was difficult to analyze because of three-dimensional magnetic circuit. This paper performed analysis of the static and dynamic characteristics of the claw-pole PM stepping motor using 3D-FEM(Finite Element Method). We also manufactured the test products and practiced performance tests for verification of the analysis results.

  • PDF

Development of Coreless Linear Motor (무철심형 리니어모터 개발)

  • 정재한
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.291-296
    • /
    • 2000
  • Liner DC motors are widely used for servo-actuator, which would be applied for semiconductor equipments and precise machining systems. we have been developed linear DC motor with high speed, acceleration and position accuracy. From performance test, the position accuracy. From performance test, the position and repeatability accuracy were able to be controlled with 10 ${\mu}{\textrm}{m}$ and $\pm$1 ${\mu}{\textrm}{m}$, respectively. The highest acceleration and speed were obtained 3 G and 2m/sec, respectively. Static thrust force was 270N, and then error was 25%.

  • PDF

Development of Interior type Permanent Magnet Synchronous Motor for Electric Golf Car (전동 골프카 구동용 매입형 영구자석 동기전동기 개발)

  • Oh, Young-Jin;Ryu, Sung-Lay;Kim, Ji-Hyun;Lee, In-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1025-1026
    • /
    • 2007
  • Recently study on components for a electric golf car and a utility car driven by a electric motor has been performed actively, and the study on a drive motor, a inverter and a battery focuses on a small, light weight and high power density source to improve fuel efficiency using limited electric energy. Especially, since a utility car such as a golf car performance depends on initial acceleration and maximum speed capability, a drive system requires high power and large and wide operation area, This study therefore investigates on the interior permanent magnet synchronous motor with high power density and wide operation, and is verified with the test result after design and characteristic analysis is performed

  • PDF

The Effect of Balance Training and environmental enrichment on motor performance after Traumatic Cerebellar Injury in the Rat (균형훈련과 환경강화가 외상성 소뇌 손상 흰쥐의 운동 수행력에 미치는 영향)

  • Song Ju-min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.72-89
    • /
    • 2004
  • The purposes of this study were to test the effect of balance training and environmental enrichment on motor performance after traumatic cerebellar injury in the rat. Traumatic cerebellar injury was induced by weight drop model and after operation they were housed in individual standard cages for 24 hours. Twenty two Sprague-Dawley rats were randomly assigned into control and experimental groups. The control group was housed in standard cage for 7 days. The experimental group I was housed in standard cage after balance training for 7 days. The experimental group II was housed in environmental enrichment cage after balance training for 7 days. Vestibular drop test and tilting plane test was examined at preoperation, on 1st day after operation and 7th day after operation to the rats. The results of this experiment were as follows: 1. In motor behavioral test, at preoperation and on 1 day after operation, the outcomes were not different among the groups. But on 7th day after operation, the outcomes of group I were better than that in control group, and group II were better than group I. These results suggest that behavioral motor outcome by simultaneously application of balance training and environmental enrichment in traumatic cerebellar injured rats were more improve than that by just balance training.

  • PDF

Experimental Analysis of Bursting Performance according to Rupture Disc Shape of Dual Pulse Motor (이중펄스모타 파열판 형상 변화에 따른 파열 영향의 실험적 분석)

  • Kwon, Tae-Ha;Cho, Won-Man;Rho, Tae-Ho;Chang, Hong-Been;Koo, Song-Hoe
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.666-669
    • /
    • 2011
  • The rupture disc shapes of bulkhead type pulse separation device(PSD) are designed for new dual pulse rocket motor. Before final design PSD, that three different rupture disc are tested and confirmed the performance of the discs. Through analyzing the test results the PSD decides, two rupture disc shapes with flow holes of eight circles and eight trapezoids.

  • PDF

Properties of Thermal Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 열적 열화특성)

  • Park Hyun-June;Lee Chang-Moo;Lee Han-Min;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.606-610
    • /
    • 2003
  • The 200 class insulation system which adopted to traction motor have excellent dielectric strength but weaken to thermal stress therefore deterioration phenomena analysis according to thermal stress is necessary. Accelerated thermal aging tests have been used to determine thermal reliability of stator coils used as traction motor in electric multiple unit. The conventional aging test is carried on according to IEC 60034-18-31 and IEEE Std. 275-1992. Variation in insulation resistance, P.I, capacitance, dielectric loss($tan{\delta}$) and partial discharge are measured during the aging cycle. Sample coils for traction motor were tested by accelerated aging test which composed of heat, vibration and moisture. Reliability and expected life were evaluated on the insulation system for traction motor.

  • PDF

Strength Training-Induced Changes in Muscle Size and Motor Improvement in Bilateral Schizencephaly: An Experimenter-Blind Case Report With 3-Month Follow-Up

  • Lee, Dong-Ryul;You, Sung-Hyun;Lee, Nam-Gi;Yoo, In-Gyu;Jung, Min-Ye;Han, Bong-Soo
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.77-87
    • /
    • 2010
  • The present case study highlights the effects of a novel Comprehensive Hand Repetitive Intensive Strengthening Training (CHRIST) on morphological changes and associated upper extremity (UE) muscle strength and motor performance in a child with spastic quadriplegic cerebral palsy (CP). The Child, a 10-year-old girl with spastic quadriplegic CP, was treated with CHRIST for 60 minutes a day, five times a week, for 5 weeks. The CHRIST was designed to improve motor function and strength. Clinical tests including the modified Wolf Test, Jebsen-Taylor Hand Function Test, and Pediatric Motor Activity Log questionnaire were used to determine motor function. Ultrasound imaging was performed to determine the changes in the cross-section area (CSA) of the extensor carpi radialis (ECR) and triceps brachii (TRI). Muscle strength was measured with a dynamometer at pretest, and post-test, and 3-month follow-up. Ultrasound imaging data showed that the CSAs of both ECR and TRI muscles were enhanced as a function of the intervention. These changes were associated with muscle strength and motor performance and their effects remained even at a 3-month follow-up test. Our results suggest that the CHRIST was effective at treating muscle atrophy, weakness and motor dysfunction in a child with spastic quadriplegic CP.

A study on the development of motor-driven artificial heart and its control (인공심장의 자동제어)

  • 민병구;김희찬;권성일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.643-647
    • /
    • 1986
  • A new type of motor-driven Total Artificial Heart (TAH) system with rolling-ball mechanism has been developed. To test its performance as a Left Ventricular Assist Device (LVAD), LVAD is controlled to bypass blood for impaired heart triggered by the R-wave in ECG. Results of the test with a Mock Circulation System (MCS) and an animal experiment with a dog are also included. More powerful system using a brushless DC motor has been developed and its control scheme is represented.

  • PDF