• Title/Summary/Keyword: Motion analysis system

Search Result 2,509, Processing Time 0.083 seconds

The Kinematic Analysis of High-Speed Reciprocating Feeding Mechanism (고속왕복 이송 시스템의 운동해석에 관한 연구)

  • No, Chang-Su;Sin, Jung-Ho
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.99-104
    • /
    • 1988
  • The method of simulation for ballistic feeding mechanical system is presented. Taking photograph of roller drived by a force of explosion, searches the motion of roller. The algorithm that a motion of roller is converted into a motion of cam is presented. Using central difference method, the angular velocity and acceleration of cam is evaluated.

  • PDF

Motion analysis of a Translating Flexible Beam Carrying a Moving Mass (이동부하를 가지고 병진운동하는 유연보의 운동 해석)

  • Park, Sang-Deok;Chung, Wan-Kyun;Youm, Young-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.11
    • /
    • pp.204-212
    • /
    • 1999
  • In this paper, the vibrational motion of a flexible beam clamped on a translating base and carrying a moving mass is investigated. The equations of motion which describe the total dynamics of the beam-mass-cart system are derived and the coupled dynamic equations are solved by unconstrained modal analysis. In modal analysis, the exact normal mode solutions corresponding to the eigenfrequencies for the position of the moving mass and the ratios of the mass of the flexible beam, the moving mass and the base cart are used. Proper transformations of the time solutions between the normal modes for a position and those for the next position of the moving mass are also adopted. Numerical simulations are carried out to obtain the open-loop responses of the system in tracking the pre-designed path of the moving mass.

  • PDF

Reliability of 3D-Inertia Measurement Unit Based Shoes in Gait Analysis (관성센서 기반 신발형 보행 분석기의 신뢰성 연구)

  • Joo, Ji-Yong;Kim, Young-Kwan;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.123-130
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the reliability of 3D-inertia measurement unit (IMU) based shoes in gait analysis. This was done with respect to the results of the optical motion capturing system and to collect reference gait data of healthy subjects with this device. Methods : The Smart Balance$^{(R)}$ system of 3D-IMU based shoes and Osprey$^{(R)}$ motion capturing cameras were used to collect motion data simultaneously. Forty four healthy subjects consisting of individuals in 20s (N=20), 40s (N=13), and 60s (N=11) participated in this study voluntarily. They performed natural walking on a treadmill for one minute at 4 different target speeds (3, 4, 5, 6 km/h), respectively. Results : Cadence (ICC=.998), step length (ICC=.970), stance phase (ICC=.845), and double-support phase (ICC=.684) from 3D-IMU based shoes were in agreement with results of optical motion system. Gait data of healthy subjects according to different treadmill speeds and ages were matched to previous literature showing increased cadence and reduced step length for elderly subjects. Conclusion : Conclusively, 3D-IMU based shoes in gait analysis were a satisfactory alternative option in measuring linear gait parameters.

Random Analysis of Rolling Equation of Motion of Ships Based on Moment Equation Method (모멘트 방정식 방법에 의한 횡요 운동 방정식의 램덤 해석)

  • 배준홍;권순홍;하동대
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.41-45
    • /
    • 1992
  • In this paper an application technique of moment equation method to solution of nonlinear rolling equation of motion of ships is investigated. The exciting moment in the equation of rolling motion of ships is described as non-white noise. This non-white exciting moment is generated through use of a shaping filter. These coupled equations are used to generate moment equations. The nonstationary responses of the nonlinear system are obtained. The results are compared with those of a linear system.

  • PDF

Biomechanical Analysis of Arm Motion during Steering Using Motion Analysis Technique (동작분석기법을 이용한 조향동작에 대한 팔의 생체역학적 특성분석)

  • Kim, Young-Hwan;Tak, Tea-Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1391-1398
    • /
    • 2011
  • Biomechanical analysis of arm motion during steering was performed using a motion analysis technique. Three-dimensional position data for each part of arm are fed into an interactive model combining a musculoskeletal arm model and the mechanical steering system to calculate joint angles and torques using inverse kinematic and dynamic analyses, respectively. The analysis shows that elbow pronation/supination, wrist flexion/extension, shoulder adduction/abduction, and shoulder flexion/extension have significant magnitudes. Sensitivity analysis of the arm joint motion with respect to seating posture and steering wheel configuration is carried out to investigate the qualitative influence of the seating posture and driver's seat configuration on the steering behavior.

Integrated Dynamic Simulation of a Magnetic Bearing Stage and Control Design (자기베어링 스테이지의 동적 거동 통합 시뮬레이션을 통한 제어 설계)

  • Kim, Byung-Sub
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.730-734
    • /
    • 2013
  • The dynamic simulation of machine tools and motion control systems has been widely used for optimization, design verification, control design, etc. There are three main streams in dynamic simulation: structural dynamic analysis based onthe finite element method, dynamic motion analysis based on equations of motion, and control system analysis based on transfer functions. Generally, one of these dynamic simulation methods is chosen and employed for specific purposes. In this study, an integrated dynamic simulation is introduced, in which the structure, motion, and control dynamics are combined together. Commercially well-known software is used in the integrated dynamic simulation: ANSYS, ADAMS, and Matlab/Simulink. Using the integrated dynamic simulation, the dynamics of a magnetic bearing stage is analyzed and the causes of oscillation and noise are identified. A controller design for suppressing a flexible dynamic mode is carried out and verified through the integrated dynamic simulation.

Improvement of Vibration Performance for Wafer Transfer Robot using Frequency Analysis of Motion Profile (모션프로파일의 주파수분석을 통한 웨이퍼 이송로봇의 진동성능 향상)

  • Shin, Dongwon;Yun, Jang Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.8
    • /
    • pp.697-703
    • /
    • 2014
  • This paper is study of solving vibration problem occurred in moving hand of wafer transfer robot in semiconductor manufacturing line. Long settling time for decreasing vibration makes low production rate, and moreover the excessive vibration of hand sometimes breaks the wafer in a cassette. The ways of reducing the moving speed and changing the type of motion profile did not help for lessening vibration. Therefore, we analyzed the mechanical property of the hand such as natural frequency, and frequency component of the motion profile currently used in the manufacturing line. In several conditions of motion profile, we found the best condition of which the frequency component in near of natural frequency of the hand is minimal and this induced small vibration in moving hand. The results were verified theoretically and experimentally using frequency analysis.

A Numerical Simulation for the Propulsion of Axisymmetric Micro-Hydro-Machine by Contractive and Dilative Motion (수축팽창 운동에 의한 축대칭 마이크로-하이드로-머신의 추진을 위한 수치 시뮬레이션)

  • Kim Moon-Chan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.30-37
    • /
    • 2001
  • A Numerical simulation for the propulsion of axisymmetric body by contractive and dilative motion is carried out. The present analysis shows that a propulsive force can be obtained in highly viscous fluid by a contractive and dilative motion of axisymmetric body. An axisymmetric analysis code is developed with unstructured grid system for the simulation of complicated motion and geometry. The developed code is validated by comparing with the results of stokes approximation with the problem of uniform flow past a sphere in low Reynolds number($R_n=1$). The validated code is applied to the simulation of contractive and dilative motion of body. The simulation is extended to the analysis of waving surface with projecting part for finding out the difference of hydrodynamic performance according to the variation of waving surface configuration. The present study will be the basic research for the development of the propulsor of an axisymmetric micro-hydro-machine.

  • PDF

Dynamic Characteristics of Linear Motion Guide Supported by Rolling Ball Bearings (볼 베어링을 이용 Linear Motion Guide의 동적 특성에 관한 연구)

  • 최재석;이용섭;김윤영;이동진;이성진;유정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.326-331
    • /
    • 2004
  • The linear motion (LM) guide using ball bearing has many advantages compared with conventional sliding guides. Therefore, LM guide using ball bearing has been used widely to increase the accuracy of the position of a system. This research investigates dynamic characteristics of LM guide through mainly linear analysis. Linear analysis is accomplished by Lagrange equation and finite element method. And another trial that is nonlinear analysis about one mode of LM guide(bouncing mode) from Hertzian contact theory is accomplished in the latter half of this research. Through nonlinear analysis we could observe the softening characteristic due to the Hertzian contact nonlinearity.

  • PDF

Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact (연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용)

  • Ryu, Taebeum
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.24-32
    • /
    • 2012
  • Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods, two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.