• Title/Summary/Keyword: Monitor control

검색결과 1,603건 처리시간 0.029초

IOT Intelligent Watering Sensor For Indoor Plant

  • Hana, Mujlid;Haneen Daifallah, Alghamdi;Hind Abdulaziz, Alkharashi;Marah Awadh, Alkhaldi
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.171-177
    • /
    • 2022
  • The number of people who own indoor plants is growing today, but as a result of their busy lifestyles-such as work or travel-as well as a lack of enthusiasm in caring for their plants, their plants wither. The use of an irrigation control system with a surveillance camera can assist such folks in taking care of their plants. Such a device can assist in remotely watering plants at predetermined times and checking on the health of the plants. The proprietors would be able to live comfortably without feeling bad thanks to this change. Internet access is required for this technology in order to monitor the plants and control the watering through apps. A sensor is installed in the soil to monitor soil humidity and send data to the microcontroller for irrigation, allowing the owner to schedule irrigation as they see fit and keep an eye on their plants all day. With the use of a remote irrigation control system, the plants will grow properly and be irrigated with the proper amount of water, and the owners will be so glad and delighted to watch their plants. Knowing the time and quantity of water are vital parts of the plant growth.

Discrimination of Out-of-Control Condition Using AIC in (x, s) Control Chart

  • Takemoto, Yasuhiko;Arizono, Ikuo;Satoh, Takanori
    • Industrial Engineering and Management Systems
    • /
    • 제12권2호
    • /
    • pp.112-117
    • /
    • 2013
  • The $\overline{x}$ control chart for the process mean and either the R or s control chart for the process dispersion have been used together to monitor the manufacturing processes. However, it has been pointed out that this procedure is flawed by a fault that makes it difficult to capture the behavior of process condition visually by considering the relationship between the shift in the process mean and the change in the process dispersion because the respective characteristics are monitored by an individual control chart in parallel. Then, the ($\overline{x}$, s) control chart has been proposed to enable the process managers to monitor the changes in the process mean, process dispersion, or both. On the one hand, identifying which process parameters are responsible for out-of-control condition of process is one of the important issues in the process management. It is especially important in the ($\overline{x}$, s) control chart where some parameters are monitored at a single plane. The previous literature has proposed the multiple decision method based on the statistical hypothesis tests to identify the parameters responsible for out-of-control condition. In this paper, we propose how to identify parameters responsible for out-of-control condition using the information criterion. Then, the effectiveness of proposed method is shown through some numerical experiments.

Microprocessor를 이용한 Patient Monitor 개발(II) (Development of the Patient Monitor Using Microprocessor(II))

  • 김남현;김정래;허재만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.101-106
    • /
    • 1995
  • In this paper, the patient monitor consisting of ECG/Respiration Amplification, Front end CPU, Main CPU, Main Controller, Video Amplifier, Display Controller, Waveform Generator, Bus & Power Supply, 8097 Processor was developed. This patient monitor measures the patient's states in the hospital such as elecctro-cardiography, respiration, blood pressurae and temperature. The control and processing methods based on micro-processor employ the flexibility, extensibility over other conventional system. The followings are incorporated in this system. First, ECG/RESP measures the respiration by impedence pneumography. Second, FECPU utilizes an Intel 8031 microcontroller. Third, Controller function originate from a LSI CRT controller.

  • PDF

Delay Monitor Scheme을 사용한 Register Controlled Delay-locked Loop (Register Controlled Delay-locked Loop using Delay Monitor Scheme)

  • 이광희;노주영;손상희
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.144-149
    • /
    • 2004
  • Register Controlled DLL with fast locking and low-power consumption, is described in this paper. Delay monitor scheme is proposed to achieve the fast locking and inverter is inserted in front of delay line to reduce the power consumption, also. Proposed DLL was fabricated in a 0.6${\mu}{\textrm}{m}$ 1-poly 3-metal CMOS technology. The proposed delay monitor scheme enables the DLL to lock to the external clock within 4 cycles. The power consumption is 36㎽ with 3V supply voltage at 34MHz clock frequency.

Monitoring social networks based on transformation into categorical data

  • Lee, Joo Weon;Lee, Jaeheon
    • Communications for Statistical Applications and Methods
    • /
    • 제29권4호
    • /
    • pp.487-498
    • /
    • 2022
  • Social network analysis (SNA) techniques have recently been developed to monitor and detect abnormal behaviors in social networks. As a useful tool for process monitoring, control charts are also useful for network monitoring. In this paper, the degree and closeness centrality measures, in which each has global and local perspectives, respectively, are applied to an exponentially weighted moving average (EWMA) chart and a multinomial cumulative sum (CUSUM) chart for monitoring undirected weighted networks. In general, EWMA charts monitor only one variable in a single chart, whereas multinomial CUSUM charts can monitor a categorical variable, in which several variables are transformed through classification rules, in a single chart. To monitor both degree centrality and closeness centrality simultaneously, we categorize them based on the average of each measure and then apply to the multinomial CUSUM chart. In this case, the global and local attributes of the network can be monitored simultaneously with a single chart. We also evaluate the performance of the proposed procedure through a simulation study.

Classroom lecture monitoring case study

  • Baik, Jai-Wook;Yang, Geun-Dae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권4호
    • /
    • pp.1191-1200
    • /
    • 2008
  • Recently classroom monitoring is becoming important since the lecture is being held in the classroom and academic institutions are interested in the quality assurance. Some institutions have adopted ISO 9000 systems and constructed monitoring system through measurement, analysis and improvement. In this study quality assurance problems in academic institutions and the requirements of ISO 9001:2000 will be briefly discussed. Next we will investigate how to monitor the lecture in the classroom(in-class) using statistical process control techniques such as control charts. Then case study will be given to illustrate the technique to use appropriate statistics. Finally how to monitor the learning process during in-class and after-class will be proposed.

  • PDF

Pilot Bus의 정보를 이용한 효율적인 지역별 전압제어 (Effective Localized-Voltage Control Scheme using the Information from Pilot Bus)

  • 송성환;윤용태;문승일;이호철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.505-513
    • /
    • 2006
  • One of the major reasons for recent blackout, like August 14, 2003 blackout in the US and Canada has been insufficient voltage/reactive power support. For the stable reactive power management, a new approach for the voltage monitoring and control structure is required in the market environment. This paper proposes the effective localized-voltage control scheme using the information from pilot buses at each zone. In this paper, the steady state voltage monitoring and control (SSVMC) is adopted and illustrated for the voltage control scheme during steady state because it is thought as the systemic algorithm to explain voltage profile phenomenon before and after contingencies. And the concept of electrical distance is applied to simultaneously achieve both clustering the voltage control zone, and selecting the pilot bus as the representative node at each control zone. Applying SSVMC based on the structure with clustering and pilot bus enables system operators to monitor and understand the system condition much more easily, to monitor and control the voltage in real-time more manageably, and to respond quickly to a disturbance. The proposed voltage control scheme has been tested on the IEEE 14-bus system with the numerical analysis to examine the system reliability and structure efficiency.

내부자의 불법적 정보 유출 차단을 위한 접근통제 모델 설계 (An Architecture of Access Control Model for Preventing Illegal Information Leakage by Insider)

  • 엄정호;박선호;정태명
    • 정보보호학회논문지
    • /
    • 제20권5호
    • /
    • pp.59-67
    • /
    • 2010
  • 본 논문에서는 유비쿼터스 컴퓨팅 환경에서 내부자가 합법적인 권한을 이용하여 불법적인 정보 유출 행위를 차단하는 접근통제 모델 IM-ACM(Insider Misuse-Access Control Model)을 제안하였다. IM-ACM은 상황역할과 개체의 보안속성을 활용하여 보안성을 강화시킨 CA-TRBAC(Context Aware-Task Role Based Access Control)에 오용 모니터 기능을 추가하여 내부자가 데이터를 올바르게 사용하는지 감시한다. 내부자에 의한 정보 유출은 합법적인 접근권한, 접근시스템에 대한 풍부한 지식 등의 내부자의 특성으로 인해 차단하기가 곤란하다. IM-ACM은 CA-TRBAC의 장점인 상황과 보안속성을 이용하여 서로 상이한 보안등급의 객체간 정보 흐름을 방지하고 오용 모니터를 활용하여 내부자의 실제 진행 프로세스를 최근 역할, 직무와 작업 프로세스 패턴 프로파일과 비교하여 내부자의 오용행위을 차단한다.

보험심사간호사의 VDT 증후군 증상에 관한 연구 (A Study on Symptoms of VDT Syndrome among Health Insurance Review Nurses)

  • 황혜영
    • 한국직업건강간호학회지
    • /
    • 제12권2호
    • /
    • pp.134-145
    • /
    • 2003
  • Purpose: The present study examines symptoms of VDT syndrome perceived by those nurses reviewing the application of health insurance at hospitals. This study also investigates those factor influencing on the experience of VDT syndrome among those nurses. Method: Data were collected through mail questionnaire survey in April, 2003. Of the 250 questionnaires disseminated, 214 questionnaires were finally analyzed using descriptive statistics and multiple regression analysis through SPSS/PC version 10.0. Result: Of the VDT syndrome, the musculoskeletal symptom score was highest, followed by ophthalmologic symptoms. The musculoskeletal symptoms were higher among younger nurses, having smaller space under the desk, and feeling uncomfortableness of the chair. The ophthalmologic symptoms were higher among those with a bachelor's degree, younger nurses, and those having a light reflection on the computer monitor, and those maintaining less than 40cm between eyes and the monitor. Higher dermatologic symptoms were observed among younger nurses and those using unclear monitor. The psychological symptoms were higher among younger nurses, those having a light reflection on the monitor, those unable to control the height of their chair, and those using uncomfortable chair. The overall symptoms were higher among younger nurses, those having a light reflection on the monitor, and those smaller space under the desk. Conclusion: Primary intervention should be given to those nurses with symptoms of VDT syndrome in order to regain health and prevent further aggravation of the symptoms. In particular, self-care behaviors of the nurses using VDT should be promoted with administrative support.

  • PDF

인지적 요소가 포함된 과제 수행 시 젊은 성인과 노인의 동작 조절 비교 (Comparison of Cognitive Task-Directed Motor Control Ability in Younger and Older Subjects)

  • 이수아;최종덕
    • 대한물리의학회지
    • /
    • 제12권1호
    • /
    • pp.51-59
    • /
    • 2017
  • PURPOSE: This study compared cognitive task-directed functional motor control ability for reaching and kicking movements in younger and older adults. METHODS: Subjects were divided into two groups of younger and older adults, with 13 subjects in each group. Subjects were required to perform a dual task combining a functional movement and cognitive component. The task consisted of reaching and kicking movements. Participants performed indicated movements when a target appeared on a monitor. The target randomly appeared on the monitor every 10 seconds. The total performance time (TPT), joint angular velocity (JAV), and muscle activation time were used to evaluate motor control ability. RESULTS: There were significant differences in all evaluation factors in a comparison of younger and older adults (p<.05). TPT was significantly shorter in older adults, and JAV and muscle activation time were significantly slower than that in the younger adult group. Although the results for older adults were within the normal range for functional assessment, their motor control abilities were significantly worse for cognitive tasks compared with those of younger adults. CONCLUSION: The results of this study indicated that a motor control assessment tool using a cognitive task would be helpful in assessment of motor control ability in healthy older adults.