• Title/Summary/Keyword: Monitor control

Search Result 1,611, Processing Time 0.034 seconds

Implementation of Embedded Micro Web Server for Web based Remote Hardware Control and Monitor (웹 기반 하드웨어 원격감시 및 제어를 위한 초소형 내장형 웹 서버 시스템의 구현)

  • Han, Kyong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.104-110
    • /
    • 2006
  • In this paper, we proposed the micro web-server implementation on Strong ARM processor with embedded Linux. The parallel port connecting parallel I/O is controlled via HTTP protocol and web browser program HTTP protocol with Linux, the micro web server program and port control program are installed on-board memory using CGI to be accessed by web browser. The processor parallel input port is monitored and parallel output port is controlled from remote hosts via HTTP protocol. The result of the proposed embedded micro-web server can be used in remote automation systems, distributed control via internet using web browser.

Prevalence of Cystic Echinococcosis in Slaughtered Sheep as an Indicator to Assess Control Progress in Emin County, Xinjiang, China

  • Yang, Shijie;Wu, Weiping;Tian, Tian;Zhao, Jiangshan;Chen, Kang;Wang, Qinyan;Feng, Zheng
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.3
    • /
    • pp.355-359
    • /
    • 2015
  • Hydatid disease imposing serious threat on human health and great loss in live-stock pastoralism remains a major public health problem in western China. To assess and monitor the effect of control program on transmission dynamics, we used the prevalence of cystic echinococcosis in slaughtered sheep at slaughterhouse as an indicator during the period of 2007 to 2013 in Emin County, Xinjiang Uygur Autonomous Region, China. The results showed a significant decline trend of prevalence in all age groups during the 7 years when the control program was implemented; particularly, the rate was reduced by 72% after first 3 years. Among the sheep slaughtered, the age distribution evidenced that the prevalence increased significantly as the sheep grew older. The baseline data indicated that the rate was 4.5% at the age <1, 6.7% at age 2~, and reached to the highest 17.9% at age ${\geq}4$ years. Earlier response to the intervention pressure was seen in the sheep at the younger age. Significant decline started from 2008 at the age <1, from 2009 at age of 1~, 2010 at 2~ to 3~, and the latest, in 2012 at age ${\geq}4$. This study demonstrated that the prevalence of cystic echinococcosis in slaughtered sheep may be used as an indicator to assess and monitor the transmission status during and after control program providing information for betterment of performance to sustain control strength.

Development of a Wheel Slip Control System for Vehicle Cornering Stability (차량 선회 안정성을 위한 휠 슬립 제어시스템 개발)

  • Hong, Dae-Gun;Huh, Kun-Soo;Hwang, In-Yong;SunWoo, Myoung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.174-180
    • /
    • 2006
  • The wheel slip control systems are able to control the braking force more accurately and can be adapted to different vehicles more easily than conventional braking control systems. In order to achieve the superior braking performance through the wheel slip control, real-time information such as the tire braking force at each wheel is required. In addition, the optimal target slip values need to be determined depending on the braking objectives such as minimum braking distance, stability enhancement, etc. In this paper, a wheel slip control system is developed for maintaining the vehicle stability based on the braking monitor, wheel slip controller and optimal target slip assignment algorithm. The braking monitor estimates the tire braking force, lateral tire force and brake disk-pad friction coefficient utilizing the extended Kalman filter. The wheel slip controller is designed based on the sliding mode control method. The target slip assignment algorithm is proposed to maintain the vehicle stability based on the direct yaw moment controller and fuzzy logic. The performance of the proposed wheel slip control system is verified in simulations and demonstrates the effectiveness of the wheel slip control in various road conditions.

A study on the real time control of flexible manufacturing system using colored and timed Petri Nets (페트리네트를 이용한 유연생산시스템의 실시간 제어에 관한 연구)

  • 노상도;김기범;김종원;이교일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1099-1104
    • /
    • 1993
  • The real time control system for FMS(Flexible Manufacturing System) is implemented at this paper. To achieve this goal, the Colored and Timed Petri-Net model is constructed and used to simulate the real time operation of FMS. Using the Colored and Timed Petri-Net model, evaluating any kind of FMS plant is possible. On-line shceduler, intelligent dispatcher, real time monitor and the simulation model of shop floor are contructed using LAN communication, relational database system in this paper. Finally, this real time control system is applied to the FMS/CIM center at Seoul National University.

  • PDF

The configuration of optimal structure for substation SCADA system (최적규모의 변전소 집중원방감시제어(SCADA) 시스템 구성)

  • 이용해;남태현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.678-682
    • /
    • 1988
  • Current substation SCADA system has only one control center where two or three operaters monitor and control more than 40 substations spreaded far and wide. The scope of this system is too wide to cope with the concurrent multiple accidents in electric network by the typhoon and large mow. This paper describes the method to organize the optimal structure of substation SCADA system using remote console and small scale control center.

  • PDF

Plasma control Using a Linear Quadratic Regulated RF Impedance Match Process

  • Kim, Byung-Whan;Park, Jang-Hyun;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.31.2-31
    • /
    • 2001
  • A real-time control strategy is presented for plasma control Rather than in-situ plasma variables, this is based on realtime measurements of two electrical positions that correspond to two match motors. Using the rf match monitor system, the positions were collected. The process of impedance matching was identified with variations in process factors, including rf power, pressure, and O$_2$ flow rate. A state-space model was obtained basing on autoregressive moving average model. For this model, a linear quadratic regulator was designed and applied. Simulation results revealed that match positions could accurately be regulated to follow certain positions arbitrarily chosen.

  • PDF

A Novel Test Structure for Process Control Monitor for Un-Cooled Bolometer Area Array Detector Technology

  • Saxena, R.S.;Bhan, R.K.;Jalwania, C.R.;Lomash, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.299-312
    • /
    • 2006
  • This paper presents the results of a novel test structure for process control monitor for uncooled IR detector technology of microbolometer arrays. The proposed test structure is based on resistive network configuration. The theoretical model for resistance of this network has been developed using 'Compensation' and 'Superposition' network theorems. The theoretical results of proposed resistive network have been verified by wired hardware testing as well as using an actual 16x16 networked bolometer array. The proposed structure uses simple two-level metal process and is easy to integrate with standard CMOS process line. The proposed structure can imitate the performance of actual fabricated version of area array closely and it uses only 32 pins instead of 512 using conventional method for a $16{\times}16$ array. Further, it has been demonstrated that the defective or faulty elements can be identified vividly using extraction matrix, whose values are quite similar(within the error of 0.1%), which verifies the algorithm in small variation case(${\sim}1%$ variation). For example, an element, intentionally damaged electrically, has been shown to have the difference magnitude much higher than rest of the elements(1.45 a.u. as compared to ${\sim}$ 0.25 a.u. of others), confirming that it is defective. Further, for the devices having non-uniformity ${\leq}$ 10%, both the actual non-uniformity and faults are predicted well. Finally, using our analysis, we have been able to grade(pass or fail) 60 actual devices based on quantitative estimation of non-uniformity ranging from < 5% to > 20%. Additionally, we have been able to identify the number of bad elements ranging from 0 to > 15 in above devices.

Design and Implementation of Mobile VNC System for GUI Control and Monitoring of Remote Computer (원격 컴퓨터의 GUI 제어와 모니터링을 위한 Mobile VNC 시스템 설계 및 구현)

  • Chon Hee-ja;Seo Jung-Hee;Park Hung-Bog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.912-919
    • /
    • 2005
  • The Growth in wireless Internet has made Networking possible at anytime and anywhere. So mobile devices like cellular phone and PDA are now used in various fields. In particular, the mobility of mobile devices has a great advantage in remote control. This paper designed and implemented a Mobile VNC system that transmitted the screen image of a remote computer, control the remote computer GU and monitor all by cellular phone. The proposed system consists of a Mobile Viewer un on the cellular phone, VNC Server m on a number of remote computers and a VNC Monitor. For communication between the VNC Server and the Mobile Viewer the MRFB protocol is used. The screen image transmitted to the Mobile Viewer is encoded in the PNG format supported by SK-VM, the Java execution environment of the Cellular phone. According to implementation results, the image is about $2KB\~8KB$. According to the 65 times transmission test, the average frame per second is 4.93fps in the emulator and a real cellular phone takes 0.8fps. Therefore, the proposed system is more efficient than existing systems.

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF