• Title/Summary/Keyword: Mode II test

Search Result 167, Processing Time 0.03 seconds

Design of 2 Axles Fatigue Test JIG for the Materialization of Mixed Mode (Mode I+II) (혼합모드(Mode I+II)구현을 위한 2축 피로시험 JIG 설계)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Kim, Jam-Kyu;Choi, Myoung-Su;Kim, Woo-Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • Elements of a mechanical structure are getting from multi-axles stress. so fatigue characteristic experiment Shall execute in multi-axles stress state. it is very hard to apply according to forms of a testing machine and implementation. In this study, 2 axles fatigue testing machine did a design and Development. a new JIG developed to realize a mixed mode. a stress state in mixed mode of a specimen had each other comparison using the Finite element method to examine propriety of a new JIG.

  • PDF

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

  • Baysal, Asli;Uysal, Tancan;Gul, Nisa;Alan, Melike Busra;Ramoglu, Sabri Ilhan
    • The korean journal of orthodontics
    • /
    • v.42 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Objective: We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods: We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), $0.016{\times}0.022$-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results: Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions: Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers.

Ground Vibration Test for Korea Sounding Rocket - II PFM (과학로켓 2호(KSR-II) 준비행 모델의 지상 진동 시험)

  • 우성현;김홍배;문상무;이상설;문남진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.546-551
    • /
    • 2001
  • Space Test Department at KARI(Korea Aerospace Research Institute) plans to carry out the GVT(Ground Vibration Test) for the KSR(Korea Sounding Rocket)-III FM(Flight Model) which is being developed by Space Technology R&D Division. KSR-III will be an intermediate to the launch vehicle capable of carrying satellites to their orbits. GVT offers very important information to predict the behavior of KSR in its operation, and to develop the flight control and aerodynamic analysis. For development of test facilities, testing and analysis methods which can be used for the future test, Space Test Department has performed the GVT with KSR-II PFM(Proto-Flight Model) at Satellite Integration & Test Center of KARl This paper discusses the procedures, techniques and the results of it. In this test, to simulate free-free condition, test object hung in the air by 4 bungee cords specially devised. The GVT was carried out using pure random excitation technique with MIMO(Multi-Input-Multi-Output) method with three electromagnetic shakers, and poly-reference parameter estimation was used to identify the modal parameters. As the result of the test, 11 mode shapes and modal parameters below 200㎐ were identified and compared with analytical results.

  • PDF

Mixed-Mode Fatigue Crack Growth Behavior of Cracks in Mechanical Joints Considering Critical Inclined Angle (임계 경사각을 고려한 기계적 체결부 균열의 혼합모드 피로균열성장 거동)

  • Heo, Sung-Pil;Yang, Won-Ho;Chung, Ki-Hyun;Ryu, Myung-Hai
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.187-192
    • /
    • 2001
  • Cracks in mechanical joints is generally under mixed-mode and there is the critical inclined angle at which mode I stress intensity factor becomes maximum. In order to evaluate the fatigue life of cracks in mechanical joints, horizontal crack normal to the applied load and located on minimum cross section is major concern but critical inclined crack must also be considered. In this paper mixed-mode fatigue crack growth test is performed for horizontal crack and critical inclined crack in mechanical joints. Fatigue crack growth path is predicted by maximum tangential stress criterion using mode I and mode II stress intensity factors obtained from weight function method, and fatigue crack growth rates of horizontal and inclined crack are compared.

  • PDF

Comparison of Geogrid Bonding Methods under Asphalt Overlay Layer for Reflection Cracking Retardation (아스팔트 덧씌우기 하부의 Geogrid 부착방법에 따른 반사균열 지연특성 비교)

  • Doh, Young-Soo;Kim, Bun-Chang;Ko, Tae-Young;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.9-20
    • /
    • 2005
  • This study was carried out to select most efficient bonding methods of geogrid at the interface of old concrete pavement before placing asphalt overlay layer for reflection cracking retardation. Three bonding methods, a RSC-4 emulsified asphalt, a compound and an unsaturated polyester resin (UPR) were compared in this study. Three types of asphalt mixture (AC 60-80, RLDPE 8%, PG 76-22) and a dense-graded aggregate were used for overlay asphalt pavement. A reinforcing material which consists of a woven fabric underneath a glass fiber grid was used. An expedite test method which is for simulating mixed mode (mode I and II) fracture test was performed using a wheel tracker in laboratory. Cracking development by load repetition was measured as fatigue life (number of load cycle) and expansion of specimen body were measured for each test specimen. The results showed that UPR was the best and RSC-4 the next. But considering field applicability, RSC-4 was considered as an appropriate choice for bonding reinforcing material.

  • PDF

Analysis of Acoustic Emission Signals during Long-Term Strength Tests of Brittle Materials (취성재료의 장기 강도시험 중 미소파괴음 신호 분석)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.121-131
    • /
    • 2017
  • We studied the time-dependent behaviors of rock and concrete materials by conducting the static and dynamic long-term strength tests. In particular, acoustic emission(AE) signals generated while the tests were analyzed and used for the long-term stability evaluation. In the static subcritical crack growth test, the long-term behavior and AE characteristics of Mode I and Mode II were investigated. In the dynamic long-term strength test, the fatigue limit and characteristics of generation of AE were analyzed through cyclic four points bending test. The graph of the cumulative AE hits versus time showed a shape similar to that of the creep curve with the first, second and third stages. The possibility for evaluating the static and dynamic long-term stability of rock and concrete is presented from the log - log relationship between the slope of the secondary stage of cumulative AE hits curve and the delayed failure time.

Mehods of Fracture Toughness and Evaluation for Interface Crack in Adhesively Bonded Joints (접착이음의 계면균열에 대한 파괴인성 및 평가방법)

  • 정남용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.220-226
    • /
    • 1998
  • In this pater, a method of strength evaluation applying fracture mechanics in adhesively bonded joints of A1/A1 materials was investigated. Various adhesively bonded joints of double-cantilever beam with a interfacial crack in its adhesive layer were prepared for the fracture toughness test of comprehensive mixed mode conditions from nearly pure mode I to mode II. The experiment of fracture toughness was carried out under various mixed mode conditions with an interfacial crack and critical energy release rate, Gc by the experimental measurements of compliances was determined. From the results, fracture toughness on mixed mode with an interfacial crack is well characterized by strain energy release rate and a method of strength evaluation by the fracture toughness in adhesively bonded joints of A1/A1 materials was discussed.

  • PDF

Mathematical Modeling for Dynamic Performance Analysis and Controller Design of Manta-type UUV (만타형상 무인잠수정의 운동성능 해석 및 제어기 설계를 위한 비선형 수학모델 개발)

  • Byun, Seung-Woo;Kim, Joon-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • This paper describes the mathematical model and controller design for Manta-type Unmanned Underwater Test Vehicle (MUUTV) with 6 DOF nonlinear dynamic equations. The mathematical model contains hydrodynamic forces and moments expressed in terms of a set of hydrodynamic coefficients which were obtained through the PMM (Planar Motion Mechanism) test. Based on the 6 DOF dynamic equations, numerical simulations have been performed to analyze the dynamic performances of the MUUTV. In addition, using the mathematical model PID and sliding mode controller are constructed for the diving and steering maneuver. Simulation results show that the control performances of the MUUTV and compared with these of NPS (Naval Postgraduate School) AUV II.

Shaking Table Test Study on 3-Dimensional Floor Isolation of Main Control Room of Nuclear Power Plant (원전 주제어실 3차원 층면진시스템의 진동대 실험 연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo;Yoon, Hyun-Do
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.409-416
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional Floor Isolation System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate 3-Dimensional Floor Isolation Effectiveness. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

천연 점토를 이용한 Pb(II)의 흡착에 관한연구

  • 김강우;이한섭
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.138-144
    • /
    • 2001
  • This study was carried out to investigate characteristics and Pb(II) removal effect of natural clays in the batch mode test. The effect of parameters such as temperature, adsorption time and coexisting cations on the sorption ability and characteristics was investigated to find out whether the clays could be used as adsorbents. Several natural clays from domestic have been investigated to have high specific surface area and have minerals such as SiO$_2$ and $Al_2$O$_3$. As a result, removal effects of Pb(II) on clays were reached at equilibrium in aqueous solutions by stirring about 20 minutes. The removal effect of Pb(II) was best for Kang Jin clay than other clays in terms of fixed time. Adsorption efficiency was not influenced by the possibility of continuous treatment system of wastewater which contain heavy metals by using natural clays from domestic.

  • PDF