• 제목/요약/키워드: Mock-up experiment

검색결과 97건 처리시간 0.028초

밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(II) (The anti-corrosion study on the corrosion-sensitive areas of unpainted weathering steel bridges with closed box girder(II))

  • 송창영;이의호;이제현;박현출;최재석;노영태
    • Corrosion Science and Technology
    • /
    • 제12권4호
    • /
    • pp.191-197
    • /
    • 2013
  • This study is the second stage of developing the corrosion control technical manual about unpainted weathering steel bridge with closed box girder structures. This paper contains selection of corrosive sealant to apply into crevice of upper flange, injecting test of sealant at mock-up equipment with various condition, evaluation of experiment result. Through the experiment of injection of sealants into crevice of mock-up equipment, it is proved that the tar sealant injecting corrosion control method is useful to protect corrosion at box girder upper flange corroded by remaning rain water with calcium chloride.

Long-Term Experiments for Demonstrating Durability of a Concrete Barrier and Gas Generation in a Low-and Intermediate-Level Waste Disposal Facility

  • Kang, Myunggoo;Seo, Myunghwan;Kim, Soo-Gin;Kwon, Ki-Jung;Jung, Haeryong
    • 방사성폐기물학회지
    • /
    • 제19권2호
    • /
    • pp.267-270
    • /
    • 2021
  • Long-term experiments have been conducted on two important safety issues: long-term durability of a concrete barrier with the steel reinforcements and gas generation from low-and intermediate-level wastes in an underground research tunnel of a radioactive waste disposal facility. The gas generation and microbial communities were monitored from waste packages (200 L and 320 L) containing simulated dry active wastes. In the concrete experiment, corrosion sensors were installed on the steel reinforcements which were embedded 10 cm below the surface of concrete in a concrete mock-up, and groundwater was fed into the mock-up at a pressure of 2.1 bars to accelerate groundwater infiltration. No clear evidence was observed with respect to corrosion initiation of the steel reinforcement for 4 years of operation. This is attributed to the high integrity and low hydraulic conductivity of the concrete. In the gas generation experiment, significant levels of gas generation were not measured for 4 years. These experiments are expected to be conducted for a period of more than 10 years.

ASUSD nuclear data sensitivity and uncertainty program package: Validation on fusion and fission benchmark experiments

  • Kos, Bor;Cufar, Aljaz;Kodeli, Ivan A.
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2151-2161
    • /
    • 2021
  • Nuclear data (ND) sensitivity and uncertainty (S/U) quantification in shielding applications is performed using deterministic and probabilistic approaches. In this paper the validation of the newly developed deterministic program package ASUSD (ADVANTG + SUSD3D) is presented. ASUSD was developed with the aim of automating the process of ND S/U while retaining the computational efficiency of the deterministic approach to ND S/U analysis. The paper includes a detailed description of each of the programs contained within ASUSD, the computational workflow and validation results. ASUSD was validated on two shielding benchmark experiments from the Shielding Integral Benchmark Archive and Database (SINBAD) - the fission relevant ASPIS Iron 88 experiment and the fusion relevant Frascati Neutron Generator (FNG) Helium Cooled Pebble Bed (HCPB) Test Blanket Module (TBM) mock-up experiment. The validation process was performed in two stages. Firstly, the Denovo discrete ordinates transport solver was validated as a standalone solver. Secondly, the ASUSD program package as a whole was validated as a ND S/U analysis tool. Both stages of the validation process yielded excellent results, with a maximum difference of 17% in final uncertainties due to ND between ASUSD and the stochastic ND S/U approach. Based on these results, ASUSD has proven to be a user friendly and computationally efficient tool for deterministic ND S/U analysis of shielding geometries.

동절기 콘크리트공사시 콘크리트의 온도해석기법에 관한 실험적 연구 (An Experimental Study on Temperature Analysis Method of Concrete in Cold-Weathering Concrete Constructions)

  • 이도범;김효락;박지훈;최일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.801-806
    • /
    • 2001
  • In the latest, the construction period became the most important factor in the domestic building works because buildings is higher and larger gradually. Accordingly, cold-weathering concrete constructions are performed more and more. So, the demands of concrete quality management methods are increased in cold-weathering concrete constructions. In this study, the mock-up experiment was performed to correct input data in the kimpo H construction field. Using the results of this experiment, the method of temperature analysis was presented to prevent early aged freezing damage and to control thermal crack in this study.

  • PDF

커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험 (A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area)

  • 김승철;윤종호;신우철;안정혁
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

모형실험을 통한 식생형 방음벽의 소음저감 효과 분석 (An analyses of the noise reduction effect of vegetation noise barrier using scaled model experiments)

  • 한찬훈;홍성신
    • 한국음향학회지
    • /
    • 제35권3호
    • /
    • pp.223-233
    • /
    • 2016
  • 공동주택단지 및 학교 및 근린시설의 경계방음벽으로 제시한 식생형 방음벽을 설계하고 소음감쇠성능실험을 실시하였다. 본 논문에서 제시한 식생형 방음벽은 일정한 형태의 유닛을 방음벽 형태의 구조물에 걸이식으로 적층하여 구성된 것으로서, 유닛내부에는 식재 및 토양을 포함하고 있다. 이 방음벽의 음향적인 장점은 토양 및 식재를 이용한 흡음뿐만 아니라 확산형상의 방음벽에서 표면 확산으로 인해 음에너지가 분산되어 소음을 저감할 수 있을 것으로 예상된다. 먼저 1/10 축소모형 실험을 통해 소음감쇠성능에 가장 적합한 방음벽 유닛의 크기를 조사하였으며, 설계된 도면에 따라 1/2축척의 식생형 방음벽을 실제높이 2 m, 길이 5 m로 제작하여 소음감쇠실험을 진행하였다. 식물을 담을 수 있는 총 1,137개의 식생블록은 약 $10{\times}10{\times}9cm$ 크기로 합성목재를 활용해 제작하였으며 이 블록들을 방음벽에 설치하여 자립형 구조를 가진 식생형 방음벽을 완성하였다. 연구결과, 평면형 방음벽보다 블록식 방음벽이 약 7 dB 더 높은 삽입손실을 나타냈으며, 식생블록의 크기는 삽입손실효과가 큰 $20{\times}20cm$의 크기가 적정한 것으로 나타났다.

철도터널 화재유동 실험을 위한 모형 터널에서의 환기 유동 형태에 관한 연구 (The Study on The Ventilated Flow in The Railway Tunnel Mock-Up for Tunnel Fire-Driven Flow Experiment)

  • 장용준;김승태;김동현;박원희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1781-1788
    • /
    • 2008
  • 본 연구는 철도 터널에서의 화재유동 실험을 위하여 제작된 모형 터널에서의 환기 유동 효과를 생성시키기 위하여 모형 터널 내에 제연 팬 및 주파수 방식의 인버터(invert control)를 설치하여 터널내의 유속을 변형시키면서 환기유동의 형태가 어떻게 생성되는지에 대한 기초연구를 수행한 결과이다. 본 실험에 사용된 덕트는 길이10m, 높이0.5m, 폭0.25m로서 아크릴로 제작하였고, 제연 및 환기유동을 위하여 최대 10m/sec의 유속을 발생시키는 모터를 장착한 제연시스템을 제작하였다. 덕트의 입구에는 터널에 존재하는 난류유동을 생성시키기 위하여 하니컴을 설치하였다. 환기유동을 모사 하고자 제연시스템을 이용하여 모형터널 내에서 4m/s, 6m/s, 8m/s로 유속를 발생시켜 각각의 유동의 형태를 조사하였다. 덕트내에서 1m간격으로 Hot wire(TSI) 및 Pressure sensor(ENDEVCO)를 설치하여 유속 및 압력을 계측하였다. 유속 및 압력은 Lap view 프로그램 및 PC를 이용하여 자동적으로 계측하여 저장하였으며, 하니컴으로 인한 난류 발생의 정도 및 모형 터널내에서의 유속의 특징을 자세히 조사하였고, 덕트 내에서의 압력 분포의 특징 및 압력 강하 등을 조사하였다.

  • PDF

EP 나일론섬유를 혼입한 자기충전콘크리트(SCC)에 관한 실험적 연구 (An Experimental Study on the Self-Consolidating Concrete with EP Nylon Fiber)

  • 류재석;이용수;전중규;전찬기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.159-168
    • /
    • 2011
  • 본 연구에서는 분산제 코팅을 통해 성능 개선된(EP) 나일론 섬유를 혼입한 자기충전 콘크리트의 가능성을 알아보고자 하였으며, 이를 위한 실험 방법으로 나일론 섬유 길이와 다른 유기계 섬유(폴리프로필렌, 셀룰로오스)를 혼입한 경우 그리고 광물질 혼화재(고로슬래그 미분말, 플라이애쉬)의 종류를 달리 혼합한 2성분계 및 3성분계의 경우를 가지고 자기충전 콘크리트의 특성을 검토하였다. 이 실험 결과를 토대로 하여 실구조물 적용을 위한 Mock-up Test를 성능 개선된 나일론 섬유를 혼입한 자기충전콘크리트 와 일반콘크리트를 비교하여 실구조물 활용 가능성을 검토 하였다. 그 결과 굳지 않은 자기충전 콘크리트의 특성, 경화된 자기충전 콘크리트의 특성 및 내구특성을 종합해 볼 때 성능 개선된(EP) 나일론 섬유가 우수함을 알 수 있었고, 성능 개선된 나일론 섬유에 따른 광물질 혼화재 사용에서는 플라이애쉬 보다 고로슬래그 미분말이 우수함을 알 수 있었다.

주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구 (Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System)

  • 윤종호;한규복;안영섭
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.

An Automatic Diagnosis Methods for Impact Location Estimation

  • 김정수;류준
    • 전기전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.101-108
    • /
    • 1999
  • 본 논문은 금속파편이 발생시 금속파편의 위치를 추정하기위한 위치 추정 알고리즘을 제안한다. 이 추정 알고리즘은 자동화된 알람 구별부와 위치 추정부로 구성된다. 알람 구별부는 충격 신호인지 거짓 충격 신호인지를 구별하는 기능을 수행하며, 위치 추정부는 충격신호로부터 충격신호의 시작점을 찾아내어 위치를 추정한다. 이 알고리즘의 타당성을 검증하기위해 원자로 Mock-up 상에서 실험한 결과 위치 추정값 과 실제 충격값이 약 10 % 이내의 오차율을 보였다.

  • PDF