• 제목/요약/키워드: Mixed signal

검색결과 463건 처리시간 0.029초

Study on Fast-Changing Mixed-Modulation Recognition Based on Neural Network Algorithms

  • Jing, Qingfeng;Wang, Huaxia;Yang, Liming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권12호
    • /
    • pp.4664-4681
    • /
    • 2020
  • Modulation recognition (MR) plays a key role in cognitive radar, cognitive radio, and some other civilian and military fields. While existing methods can identify the signal modulation type by extracting the signal characteristics, the quality of feature extraction has a serious impact on the recognition results. In this paper, an end-to-end MR method based on long short-term memory (LSTM) and the gated recurrent unit (GRU) is put forward, which can directly predict the modulation type from a sampled signal. Additionally, the sliding window method is applied to fast-changing mixed-modulation signals for which the signal modulation type changes over time. The recognition accuracy on training datasets in different SNR ranges and the proportion of each modulation method in misclassified samples are analyzed, and it is found to be reasonable to select the evenly-distributed and full range of SNR data as the training data. With the improvement of the SNR, the recognition accuracy increases rapidly. When the length of the training dataset increases, the neural network recognition effect is better. The loss function value of the neural network decreases with the increase of the training dataset length, and then tends to be stable. Moreover, when the fast-changing period is less than 20ms, the error rate is as high as 50%. As the fast-changing period is increased to 30ms, the error rates of the GRU and LSTM neural networks are less than 5%.

Mixed Weighted Filter for Removing Gaussian and Impulse Noise

  • Yinyu, Gao;Kim, Nam-Ho
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.379-381
    • /
    • 2011
  • The image signal is often affected by the existence of noise, noise can occur during image capture, transmission or processing phases. noises caused the degradation phenomenon and demage the original signal information. Many studies are being accomplished to restore those signals which corrupted by mixed noise. In this paper, we proposed mixed weighted filter for removing Gaussian and impulse noise. we first charge the noise type, then, Gaussian is removed by a weighted mean filter and impulse noise is removed by self-adaptive weighted median filter that can not only remove mixed noise but also preserve the details. And through the simulation, we compared with the conventional algorithms and indicated that proposed method significant improvement over many other existing algorithms and can preserve image details efficiently.

  • PDF

Modified Weighted Filter Algorithm for Noise Elimination In Mixed Noise Environments

  • ;김남호
    • 융합신호처리학회논문지
    • /
    • 제13권2호
    • /
    • pp.63-69
    • /
    • 2012
  • Noise is regarded as an unwanted component of the image because it significantly reduces image quality. And image is often corrupted by mixed noise. In this paper an efficient modified weighted filter algorithm which combines spatial weight and intensity weight is proposed for removing mixed noise. In the proposed method, the filtering mask is separated into the four sub-windows and the parameters of the weights are confirmed by calculating local standard deviation and the mean of four sub-windows' standard deviations. Considering the spatial information and intensity information, the proposed method has good performance on not only noise elimination but also preservation of details. Simulation results demonstrate that the proposed method performs better than conventional algorithms.

독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구 (A Study on Blood Flow Measurement Method using Independent Component Analysis)

  • 조석빈;임동석;백광렬
    • 전자공학회논문지SC
    • /
    • 제44권2호
    • /
    • pp.10-17
    • /
    • 2007
  • 의료용 초음파 시스템으로 혈류 속도를 측정할 때, 순수한 혈류 신호의 검출이 필요하다. 초음파 트랜스듀서를 통해 들어오는 반사 신호는 체세포 조직(tissue), 혈관 벽(blood wall), 적혈구(red blood cell), 잡음(noise) 등이 혼합된 신호이다. 혼합된 신호에서 체세포 조직과 혈관 벽 신호를 클러터(clutter)라고 한다. 본 논문에서는 ICA(independent component analysis)를 적용하여 클러터 신호와 잡음을 효과적으로 제거하는 방법을 제시하였다. Field II 초음파 시뮬레이션 프로그램을 이용하여 초음파 반사 신호를 생성하고, ICA를 사용하여 각 독립 신호들을 분리, 클러터 신호를 제거하여 혈류 신호를 추출했다. 추출전 혈류신호를 2D 자기상관(autocorrelation) 방법으로 혈류 속도를 측정했다. 그리고 PCA(principal component analysis)방법을 적용한 고유 필터(autocorrelation) 방법으로 클러터를 제거한 결과와 비교하였다. 그 결과 잡음 환경에서의 혈류 속도 측정에 ICA 방법이 우수한 적용 결과를 보였다.

Magnetic resonance images of ameloblastoma

  • Kim Jae-Duk;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.207-213
    • /
    • 2005
  • Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.

  • PDF

독립성분 분석기법에 의한 심전도 신호의 왜곡 보정 (Suppressing Artefacts in the ECG by Independent Component Analysis)

  • 김정환;김경섭;김현태;이정환
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.825-832
    • /
    • 2013
  • In this study, Independent Component Analysis (ICA) algorithms are suggested to extract the original ECG part from the mixed signal contaminated with the unwanted frequency components and especially 60Hz power line disturbances. With this aim, we implement a novel method to suppress the baseline-wandering disturbances and power line artefacts contained in patch-electrodes sensory ECG data by separating the unmixed signal with finding the optimal weight W based on Kurtosis value. With applying brutal force and gradient ascent searching algorithm to find W, we can conclude that the unwanted frequency components especially in the ambulatory ECG data can be eliminated by Independent Component Analysis.

Measurement Accuracy of Oscillation-Based Test of Analog-to-Digital Converters

  • Mrak, Peter;Biasizzo, Anton;Novak, Franc
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.154-156
    • /
    • 2010
  • Oscillation-based testing of analog-to-digital converters represents a viable option for low-cost built-in self-testing in mixed-signal design. While numerous papers have addressed implementation issues, little attention has been paid to the measurement accuracy. In this letter, we highlight an inherent measurement uncertainty which has to be considered when deriving the parameters from the oscillation frequency.

내장 하드웨어 오버헤드를 최소화한 Specification 기반의 아날로그 및 혼합신호 회로 테스트 (Specification-based Analog and Mixed-signal Circuits Test with Minimal Built-In Hardware Overhead)

  • 이재민
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.633-634
    • /
    • 2006
  • A new specification-based analog and mixed-signal test technique using high performance current sensors is proposed. The proposed technique using current sensors built in external ATE has little hardware overhead in circuit under test and high testability without time consuming operation of test point placement algorithm.

  • PDF