• 제목/요약/키워드: Mixed Loading

검색결과 405건 처리시간 0.02초

혼합 모드 파괴 기준에서의 T응력의 영향에 관한 연구 (A Study on the Effect of T-Stress in the Mixed Mode Fracture Criterion)

  • 구재민;최태주
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.13-21
    • /
    • 2000
  • Under the mixed mode loading, it has been known that the influence of non-singular terms in the stress fields is serious, because the critical distance, ${\gamma}_o$ - the distance of nonlinear elastic region near the crack tip has no negligible value. In this paper, it has been studied on the influence of non-singular terms, T-stress, and the case of T=0, ${\sigma}cos^2{\beta}$, ${\sigma}cos(2{\beta})$ and $0.05{\sigma}cos(2{\beta})$, under uniaxial tension and compression. It has been seen that the T-stress of ${\sigma}cos(2{\beta})$ has better than others as comparing to the experimental data.

  • PDF

볼트 체결부 균열의 혼합모드 응력확대계수 해석에 대한 가중함수법의 적용 (Application of Weight Function Method to the Mixed-Mode Stress Intensity Factor Analysis of Cracks in Bolted Joints)

  • 허성필;양원호;정기현;조명래;현철승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.212-217
    • /
    • 2000
  • The reliable determination of the stress intensity factors for cracks in bolted Joints is needed to evaluate the safety and fatigue life of them widely used in mechanical components. The weight function method is an efficient technique to calculate the stress intensity factors for various loading conditions using the stresses of an uncracked model. In this paper the mixed-mode stress intensity factors for cracks in bolted joints are obtained by weight function method, in which the coefficients of weight function are determined by finite element analyses far reference loadings. The effects of the magnitude of clearance and factional coefficient on the stress intensity factors are investigated.

  • PDF

인장-굽힘모드에서 Bi-2223 초전도 테이프의 임계전류 열화거동 (Degradation Behavior of Critical Current in Bi-2223 Superconducting Tape in Bending-Tension Mixed Mode)

  • 신형섭;김병수;최호연;오상수;하동우;하홍수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.573-576
    • /
    • 2003
  • HTS superconducting tapes are now commercially available for practical applications such as magnets and cables. Since superconductors in such applications are subjected to high mechanical loads that can significantly degrade the superconducting properties, mechanical properties and the strain tolerance known as the strain effect on superconducting properties are needed to be estimated for developing superconducting devices. Influences of loading mode on the Ic degradation and the interaction on strain effect were discussed in this study.

  • PDF

무한대를 이용하는 여과평면 구성 및 하향 여과공기 거동조성과 최적집진에 관한 연구 (A Study on the Downward Filteration Movement, the Dust Collection and Filteration Plane Constitution by the use of Infinity)

  • 정동백
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.373-375
    • /
    • 1995
  • In order to turn the Bag Filter to the Purse Filter, the past system that the adverse reason is removed, the input of synthetic materiality of dust and air is placed down, and the output is placed up has been improved so that any adverse effect shall not be raised. The form of filteration mechanism is changed from a cylinder from, and the dust and air is mixed to make the entry velocity and one person can velocity of the mixed materiality become lower by the use of infinity, and the reception of filteration mechanism has been made reasonably. The dust separated from the filteration mechanism is desceded down, snd the mixde materiality is ascended up. So, a cross point is formed, and a collision and a friction is occurred from its process, and at its result, dust is scattered to stick to a filter cloth, therefore, the loss of pressure shall ont be appeared by cause of the increase of dust-loading.

  • PDF

Experimental and Kinetic Studies of Esterification of Glycerol Using Combustion Synthesized SO42-/CeO2-Al2O3

  • Veluturla, Sravanthi;Narula, Archna;Rao, D. Subba;Indraja., S;Kulkarni, Rajeswari. M.
    • Korean Chemical Engineering Research
    • /
    • 제56권4호
    • /
    • pp.592-599
    • /
    • 2018
  • An increase in the global production of biodiesel has resulted in the newfound significance of its byproduct, glycerol. The synthesis of acetins is an economical avenue to enhance the value of glycerol derived from biodiesel. WE developed an eco-friendly process for the synthesis of fuel additives from glycerol using a mixed oxide $SO{_4}^{2-}/CeO_2-Al_2O_3$ as catalyst. The $CeO_2-Al_2O_3$ mixed oxide was synthesized by the combustion method and then sulfated. The characterization of the catalyst was by means of XRD, BET, FTIR, and SEM. The influence of temperature, mole ratio and catalyst loading on yield and selectivity of the acetins was studied for the esterification of glycerol. The reaction rate constants ($k_1$, $k_2$ and $k_3$) were estimated using optimization method in MAT lab, and the activation energies ($E_1$, $E_2$ and $E_3$) were determined by the Arrhenius equation. Furthermore, a kinetic model was developed.

炭素纖維强化 複合材料의 혼합모우드 層間破壞靭性値에 대한 硏究 (A study of mixed-mode interlaminar fracture toughness of graphite/epoxy composite)

  • 윤성호;홍창선
    • 대한기계학회논문집
    • /
    • 제10권2호
    • /
    • pp.198-207
    • /
    • 1986
  • 본 연구에서는 Fig.1과 같이 시편 부위에 균일응력분포가 작용하도록 M.Arcan 등에 의해 제시된 비대칭형상의 시편고정물에 층간균열을 가진 시편을 부착한 다음 하중각도를 바꾸어가며 모우드 II뿐 아니라 혼합모우드 및 모우드 I까지도 실험 할 수 있는 실험장치를 사용하여 균열면에서의 섬유방향이 〔0/0〕이고 초기균열길이비가 0.4, 0.5, 0.6인 시편의 모우드I, 혼합모우드 및 모우드II 층간파괴인 성치들을 실험 적으로 구해 혼합모우드 파괴결정조건식들에 적용시켜 보았다. 또한 균열면에서의 섬유방향이 〔0/0〕, 〔0/30〕, 〔0/45〕및 〔0/60〕인 경우의 층간파괴인성치와 이때 의 파괴현상에 대해 관찰하였다.

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 - (Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities -)

  • 민영희;권주영;하미경
    • 한국실내디자인학회논문집
    • /
    • 제25권3호
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.

MMB시험에 의한 평직 CFRP/GFRP 적층판 혼합모드 층간분리의 실험적 평가 (The Experimental Evaluation of the Mixed Mode Delamination in Woven CFRP/GFRP Laminates under MMB Test)

  • 곽정훈;강지웅;권오헌
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.14-18
    • /
    • 2013
  • Blades of horizontal axis are nowadays made of composite materials. Generally, composite materials satisfy design provides lower weight and good stiffness, while laminate composites have often damages as like the delamination and cracks at the interface of laminates. The box spar and tail parts of a blade are composed of the CFRP/GFRP hybrid laminate composites. However, delamination and the interfacial crack often occur in the interface of CFRP/GFRP hybrid laminate composites under the mixed mode fracture condition, especially mode I and mode II. Therefore, there is a need for the evaluation of the mixed mode fracture behavior during the delamination of CFRP/GFRP hybrid laminates. This study shows the experimental results for the delamination fracture toughness in CFRP/GFRP hybrid laminate composites. Fracture toughness experiments and estimation are performed by using DMMB(Dissimilar mixed mode bending) specimen. The materials used in the test are a commercial woven type CFRP(Carbon fiber reinforced plastic) prepreg(CF3327) and UD type GFRP(Glass fiber reinforced plastic) prepreg(HD224A). A CFRP/GFRP hybrid laminate composite is composed by the 10 plies CFRP and GFRP prepreg for DMMB. A thickness of CFRP and GFRP layer is 2.5mm and 3.0mm, respectively. Also the fulcrum location which is a loading parameter is changed from 80 to 100mm on the specimen of length 120mm because it defines the ratio of mode I to mode II. In this study, the effects of the fulcrum location are evaluated in the viewpoint of energy release rate in mode I and mode II contribution. The results show that the delamination crack initiates at higher displacement and lower load according to the increase of the fulcrum location ratio. And the variation of the energy release rate for mode I and II contributions for the mode mixity are shown.