• 제목/요약/키워드: Minimum Variance Control

검색결과 83건 처리시간 0.028초

매개변수 추정에 의한 유도전동기의 적응 벡터제어 (Adaptive Vector Control for Induction Motor Using Parameter Estimation)

  • 이윤종;김회준;오원석;김영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.363-366
    • /
    • 1990
  • In the indirect vector control method, the rotor resistance variation caused by operating temperature change is an undesirable nature. A new adaptation algorithm to compensate for the rotor resistance change based on the on-line estimation of field vector which requires the measurements of stator voltage and rotor speed is presented in this paper. Also minimum variance controller is presented for the adaptive control performance. This algorithm has been tested by simulating the induction machine using a digital computer and the results are discussed.

  • PDF

자기동조 피이드백 제어기를 이용한 적응 능동소음제어에 관한 연구 (A Study on the Adaptive Active Noise Control Using the Self-tuning feedback controller)

  • 신준;이태연;김흥섭;조성오;방승현;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 춘계학술대회논문집; 한국과학연구소, 21 May 1993
    • /
    • pp.140-146
    • /
    • 1993
  • Active noise control uses the intentional superposition of acoustic waves to create a destructive interference pattern such that a reduction of the unwanted sound occurs. In active noise control system the choice of a control structure and design of the controller are the main issues of concern. In real acoustic fields there are a vast number of noise sources with time-varying nature and the characteristics of transducers and the geometric set-up of control system are subject to change. Accordingly the control system should be designed to adapt such circumstances so that required level of performance is maintained. In this paper, the adaptive control algorithm for self-tuning adaptive controller is presented for the application in active noise control system. Self-tuning is a direct integration of identification and controller design algorithm in such a manner that the two processes proceed sequentially. The least mean square algorithm was used for the identification schemes and adaptive weighted minimum variance control algorithm was applied for self-tuning controller. Computer simulation results for self-tuning feedback controller are presented. And simulation results was shown to be useful for the situation in which the periodic noise sources act on the acoustic field.

  • PDF

미래손실에 기초한 통합공정관리계획 (An Integrated Process Control Scheme Based on the Future Loss)

  • 박창순;이재헌
    • 응용통계연구
    • /
    • 제21권2호
    • /
    • pp.247-264
    • /
    • 2008
  • 통합공정관리의 기본절차는 잡음이 내재하는 공정에 대하여 수정조치를 취하고, 수정활동 중 공정에 이상원인이 발생하면 관리도를 통하여 발생을 탐지하고 교정활동을 통하여 이를 제거하게 된다. 그러나 공정의 교정활동은 많은 시간과 비용을 수반하는 비생산적 요인을 유발할 수 있기 때문에 무조건적 교정활동은 생산성을 저하시키는 반대 급부도 동시에 내포하고 있다. 이 논문에서는 공정모형으로 ARIMA(0,1,1) 모형을 가정하고 공정 평균과 분산에 이상원인이 발생하는 경우 이를 탐지하는 절차를 소개하고, 이상신호의 시점에서 공정 잔여시간 동안 발생할 수 있는 미래손실에 기초하여 교정 활동의 여부를 판단하는 통합공정관리 절차를 제안한다.

일반화된 예측제어에 의한 가압경수형 원자로의 부하추종 출력제어에 관한 연구 (Generalized predictive control of P.W.R. nuclear power plant)

  • 천희영;박귀태;이종렬;박영환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.663-668
    • /
    • 1990
  • This paper deals with the application of a Generalized Predictive Control (CPC) to a Pressurized Water Reactor (P.W.R) Nuclear Power Plant. Generalized Predictive Control is a sort of Explicit Self-Tuning Control. Current self-tuning algorithms lack robustness to prior choices of either dead-time (input time delay of a plant) or model order. GPC is shown by simulation studies to be superior to accepted self-tuning techniques such as minimum variance and pole-placement from the viewpoint that it is robust to prior choices of dead-time or model order. In this paper a GPC controller is designed to control the P.W.R. nuclear power rlant with varying dead-time and through the designing procedure the designer is free from the constraint of knowing the exact dead-time. The controller is constructed based on the 2nd order linear model approximated in the vicinity of operating point. To ensure that this low-order model describes the complex real dynamics well enough for control purposes, model parameters are updated on-line with a Recursive Least Squares algorithm. Simulation results are successful and show the possibilities of the GPC control application to actual plants with varying or unknown dead-time.

  • PDF

자기동조 적응제어를 이용한 여자제어기 설계에 관한 연구 (A Study on the Design of Excitation Controller using Self Tuning Adaptive Control)

  • 유현호;이상근;김준현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.375-378
    • /
    • 1991
  • This paper presents a design method of synchronous generator excitation controller using self-tuning PID algorithm. Controller parameter is determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameter of controller. minimum variance algorithm using the recursive leastsquare(RLS) indentification method is adopted and the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping and conversion characteristics. The results tested on a single machine infinite bus system verify that the proposed controller has better dynamic performances than conventional controller.

  • PDF

원전 증기 발생기 수위 제어를 위한 자기 동조 제어기 설계 (Design of pole-assignment self-tuning controller for steam generator water level in nuclear power plants)

  • 최병재;노희천;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제2권4호
    • /
    • pp.306-311
    • /
    • 1996
  • This paper discusses the maintenance of the water level of steam generators at its programmed value. The process, the water level of a steam generator, has the nonminimum phase property. So, it causes a reverse dynamics called a swell and shrink phenomenon. This phenomenon is severe in a low power condition below 15 %, in turn makes the start-up of the power plant too difficult. The control algorithm used here incorporates a pole-assignment scheme into the minimum variance strategy and we use a parallel adaptation algorithm for the parameter estimation, which is robust to noises. As a result, the total control system can keep the water level constant during full power by locating closed-loop poles appropriately, although the process has the characteristics of high complexity and nonlinearity. Also, the extra perturbation signals are added to the input signal such that the control system guarantee persistently exciting. In order to confirm the control performance of a proposed pole-assignment self-tuning controller we perform a computer simulation in full power range.

  • PDF

농용트랙터의 자동조향을 위한 퍼지제어와 적응제어의 비교 (Comparison between Fuzzy and Adaptive Controls for Automatic Steering of Agricultural Tractors)

  • 노광모
    • Journal of Biosystems Engineering
    • /
    • 제21권3호
    • /
    • pp.283-292
    • /
    • 1996
  • Automatic guidance of farm tractors would improve productivity by reducing operator fatigue and increasing machine performance. To control tractors within $\pm$5cm of the desired path, fuzzy and adaptive steering controllers were developed to evaluate their characteristics and performance. Two input variables were position and yaw errors, and a steering command was fed to tractor model as controller output. Trapezoidal membership functions were used in the fuzzy controller, and a minimum-variance adaptive controller was implemented into the 2-DOF discrete-time input-output model. For unit-step and composite paths, a dynamic tractor simulator was used to test the controllers developed. The results showed that both controllers could control the tractor within $\pm$5cm error from the defined path and the position error of tractor by fuzzy controller was the bigger of the two. Through simulations, the output of self-tuning adaptive controller was relatively smooth, but the fuzzy controller was very sensitive by the change of gain and the shape of membership functions. Contrarily, modeling procedure of the fuzzy controller was simple, but the adaptive controller had very complex procedure of design and showed that control performance was affected greatly by the order of its model.

  • PDF

통합공정관리에서 일반화가능도비 관리도의 설계 (Design of the GLR Chart in Integrated Process Control)

  • 천가영;이재헌
    • Communications for Statistical Applications and Methods
    • /
    • 제17권3호
    • /
    • pp.357-365
    • /
    • 2010
  • 통합공정관리란 잡음이 내재하는 공정에 대하여 수정조치를 취하고, 수정활동 중 공정에 이상원인이 발생하면 이를 관리도를 통해 탐지하여 제거하는 절차를 일컫는다. 이 논문에서는 공정의 잡음모형으로 IMA(1,1) 모형을 가정하고 최소평균제곱오차 수정절차를 수행할 때 일반화가능도비 관리도를 사용하여 이상원인을 탐지하는 절차를 고려하고 있으며, 이러한 상황에서 일반화가능도비 관리도의 관리한계를 설정하는 설계 방법을 제안하였다. 이상원인의 효과로는 공정 평균의 지속적 변화와 지속적 흐름 그리고 공정 분산의 지속적 변화를 고려하였다.

Effect of three common hot beverages on the force decay of orthodontic elastomeric chain within a 28-day period: An in vitro study

  • Maziar Nobahari;Fatemeh Safari;Allahyar Geramy;Tabassom Hooshmand;Mohammad Javad Kharazifard;Sepideh Arab
    • 대한치과교정학회지
    • /
    • 제54권3호
    • /
    • pp.153-159
    • /
    • 2024
  • Objective: This study aimed to assess the effects of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains. Methods: This in vitro experimental study evaluated 375 pieces of elastomeric chains with six rings placed on a jig. Four rings were stretched by 23.5 mm corresponding to the approximate distance between the canine and the second premolar. Fifteen pieces served as reference samples at time zero, and 360 pieces were randomized into four groups: control, hot water, hot tea, and hot coffee. Each group was further divided into six subgroups (n = 15) according to the different exposure periods. The specimens in the experimental groups were exposed to the respective solutions at 65.5℃ four times per day for 90 seconds at 5-second intervals. The control group was exposed to artificial saliva at 37℃. The force decay of the samples was measured at 1, 2, 7, 14, 21, and 28 days using a universal testing machine. Data were analyzed using repeated-measures analysis of variance. Results: Maximum force decay occurred on day 1 in all groups. The minimum force was recorded in the control group, followed by the tea, coffee, and hot water groups on day 1. At the other time points, the minimum force was observed in the tea group, followed by the control, coffee, and hot water groups. Conclusions: Patients can consume hot drinks without concern about any adverse effect on force decay of the orthodontic elastomeric chains.

파라메터 섭동과 외란이 존재하는 강건한 적응서보 제어기의 설계 (A Design of Robust Adaptive Servo Controller in the Presence of Bounded Parameter Perturbation)

  • 홍선학;임화영
    • 한국통신학회논문지
    • /
    • 제18권7호
    • /
    • pp.1009-1017
    • /
    • 1993
  • 본 논문에서는 유계된 파라메터섭등과 외란및 측정 잡음이 존재하는 프로세스에서 점근적으로 제어기의 기준입력에 추종하고 전체 안정도를 보장하는 강건한 파라메터 적응서보 제어기를 설계하였다. 이 제어기는 평가함수를 최소화하면서 제어기 파라메터를 추정하는 구조를 갖는다. DC서보의 속도위치와 위치제어를 통해서 섭동과 외란에 대한 최소분산 제어기 파라메터 추정의 강건함을 적용해 보였다.

  • PDF