• Title/Summary/Keyword: Minimum Cycle Time

Search Result 153, Processing Time 0.027 seconds

Multi-path Routing Protocol with Optimum Routes Finding Scheme in Wireless Sensor Networks

  • Keuma, Tae-Hoon;Bu, Ki-Dong;Kim, Hyun-Sung;Lee, Sung-Woon
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2008.10b
    • /
    • pp.449-454
    • /
    • 2008
  • Finding an energy efficient route is one of the very important issues in the wireless sensor networks. The route scheme should consider both of the energy level of sensor nodes and the number of hops at the same time. First of all, this paper proposes an optimum routes finding scheme (ORFS), which could be used in the sensor network routing protocols. The scheme uses an optimum value for the path with the considerations of both the minimum energy level of a path and the number of hops at the same time. After that, this paper proposes a routing protocol based on the ORFS for how it could be used for the multipath directed diffusion with data aggregation (MDD-A), to get the better energy efficiency. The analysis result shows that the proposed routing protocol could lengthen the network life cycle about 18.7% compared to the previous MDD-A related protocols.

  • PDF

Bottleneck Detection Framework Using Simulation in a Wafer FAB (시뮬레이션을 이용한 웨이퍼 FAB 공정에서의 병목 공정 탐지 프레임워크)

  • Yang, Karam;Chung, Yongho;Kim, Daewhan;Park, Sang Chul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.3
    • /
    • pp.214-223
    • /
    • 2014
  • This paper presents a bottleneck detection framework using simulation approach in a wafer FAB (Fabrication). In a semiconductor manufacturing industry, wafer FAB facility contains various equipment and dozens kinds of wafer products. The wafer FAB has many characteristics, such as re-entrant processing flow, batch tools. The performance of a complex manufacturing system (i.e. semiconductor wafer FAB) is mainly decided by a bottleneck. This paper defines the problem of a bottleneck process and propose a simulation based framework for bottleneck detection. The bottleneck is not the viewpoint of a machine, but the viewpoint of a step with the highest WIP in its upstream buffer and severe fluctuation. In this paper, focus on the classification of bottleneck steps and then verify the steps are not in a starvation state in last, regardless of dispatching rules. By the proposed framework of this paper, the performance of a wafer FAB is improved in on-time delivery and the mean of minimum of cycle time.

The Solar-Type Contact Binary BX Pegasi Revisited

  • Lee, Jae-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Youn, Jae-Hyuck
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.24.2-24.2
    • /
    • 2009
  • We present the results of new CCD photometry for the contact binary BX Peg, made during three successive months beginning on September 2008. As do historical light curves, our observations display an O'Connell effect and the November data by themselves indicate clear evidence for very short-time brightness disturbance. For these variations, model spots are applied separately to the two data set of Group I (Sep.--Oct.) and Group II (Nov.). The former is described by a single cool spot on the secondary photosphere and the latter by a two-spot model with a cool spot on the cool star and a hot one on either star. These are generalized manifestations of the magnetic activity of the binary system. Twenty light-curve timings calculated from Wilson-Devinney code were used for a period study, together with all other minimum epochs. The complex period changes of BX Peg can be sorted into a secular period decrease caused dominantly by angular momentum loss due to magnetic stellar wind braking, a light-travel-time (LTT) effect due to the gravitational effect of a low-mass third companion, and a previously unknown short-term oscillation. This last period modulation could be produced either by a second LTT orbit with a period of about 16 yr due to the existence of a fourth body or by the effect of magnetic activity with a cycle length of about 12 yr.

  • PDF

Radar identification by scan period validation (스캔주기 유효성 판별에 의한 레이더 식별)

  • Kim, Gwan-Tae
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.17-22
    • /
    • 2021
  • Radar signal analysis of electronic warfare is a technique for identifying a radar type by signal parameters(direction, radion frequency, pulse repetition interval, pulse width, scan period..) extracted from a received radar pulse. However as the modern radar and new threat environments is advanced, radar identification ambiguity arises in the process of identifying the types of radars. In this paper, we analyze the problems of the existing method and propose a new method. This technique determines the validity of the scan period by the difference in the arrival time of the radar pulse and the minimum number of scan period discrimination. Experiments proved that the scan cycle results are derived regardless of the RMS((Root Mean Square) of the input amplitude.

Time-dependent Evolution of Accretion Disk Mass in a Black Hole Microquasar Candidate A0620-00 (블랙홀 마이크로퀘이사 후보 A0620-00의 강착원반 질량의 시간적 진화)

  • Kim, Soon-Wook
    • Journal of the Korean earth science society
    • /
    • v.29 no.7
    • /
    • pp.579-585
    • /
    • 2008
  • The time-dependent evolution of disk mass for outburst limit cycle in a black hole microquasar is calculated based on the non-linear hydrodynamic model of thermally unstable accretion disk. The physical parameters such as black hole mass, disk size and mass transfer rate are adopted to reproduce the historical 1975 outburst observed in a prototype black hole X-ray nova A0620-00. The time-dependent effect of irradiation from the central hot region to the disk is considered in two ways: direct irradiation and indirect irradiation reflected from hot accretion flow above the disk. The accretion disk thermal instability model can account for the bolometric luminosity appropriate to typical characteristics of system luminosity observed in X-ray transients during the whole cycle of the outburst evolution. The maximum mass of the accretion disk, ${\sim}4.03{\times}10^{24}g$, is achieved at the ignition of an outburst, and the minimum value, ${\sim}8.54{\times}10^{23}g$, is reached during the cooling decay to quiescence. The disk mass varies ${\sim}5$ times during outburst limit cycle.

Sensitivity Analysis of Burn-in Model considering Bimodal-Mixed Weibull Distribution under Free Warranty Policy (무료보증정책하에서 이봉-혼합 와이블 분포를 고려한 Burn-in 모형의 민감도 분석)

  • Song Suh-Ill;Jo Young-Chan;Park Hyun-Kyu;Shon Han-Deak
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.544-555
    • /
    • 1998
  • Although the bimodal mixed weibull distribution is used to developing burn-in model widely, the failure times for a component or a system is often truncated at some time, T, due to the obsolescence in the electronics industry. In this paper, we will determine minimum total cost and burn-in time by using the bimodal mixed weibull distribution and the truncated bimodal mixed weibull distribution under the free warranty policy. The results of this study are summarized as follows. First, when products or system is not repairable, the width of the change of burn-in time can be larger by ${\beta}_1,\;{\beta}_2$ Second, if burn-in time become longer, it will be impossible to consider the bum-in in a long time, and in this case, the burn-in time should be shorten by the acceleration burn-in. Third, in case that opportunity loss cost or repair cost is exceed the warranty cost, or the total cost of considering burn-in is larger than that of not considering burn-in, it is not existed burn-in time which makes total cost to minimize. Forth, the shorter life-cycle of product, the more burn-in times will be decreased and the cost in considering burn-in will be increased

  • PDF

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

Cardiorespiratory Fitness Is Associated with Gait Changes among Firefighters after a Live Burn Training Evolution

  • Colburn, Deanna;Suyama, Joe;Reis, Steven E.;Hostler, David
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.183-188
    • /
    • 2017
  • Background: Recommendations have been proposed for minimum aerobic fitness among firefighters but it is unclear if those criteria relate to performance on the fireground. Less fit individuals fatigue more quickly than fit individuals when working at comparable intensity and may have gait changes, increasing risk of falls. We evaluated the effect of fatigue during a live burn evolution on gait parameters and functional balance comparing them to aerobic fitness levels. Methods: A total of 24 firefighters had gait and balance tested before and after a live burn evolution. Data were stratified by aerobic fitness of greater/less than 14 metabolic equivalents (METs). Results: Analysis of gait cycles measurements before and after the live burn evolution revealed that single leg stance, cycle, and swing time decreased (p < 0.05) but there were no differences in the other measures. There were no differences in time to complete the functional balance test, or errors committed before or after a live burn evolution. When firefighters were sorted by fitness level of 14 METs, there were no differences for errors or time before or after the live burn evolution. Balance data were analyzed using a linear regression. Individuals with lower fitness levels required more time to complete the test. Conclusion: A 14-MET criterion failed to distinguish gait or balance characteristics in this group. However, less fit firefighters did require more time to complete the balance test (p = 0.003). Aerobic fitness alone does not predict gait changes among firefighters following a live burn evolution but does appear to influence functional balance.

Application of SYBR Green real-time PCR assay for the specific detection of Salmonella spp. (Salmonella spp. 특이적인 검출을 위한 SYBR Green real-time PCR 기법 적용)

  • Shin, Seung Won;Cha, Seung Bin;Lee, Won-Jung;Shin, Min-Kyoung;Jung, Myunghwan;Yoo, Anna;Jung, Byeng Yeal;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.1
    • /
    • pp.25-28
    • /
    • 2013
  • The aim of this study was to applicate and evaluate a SYBR Green real-time PCR for the specific detection of Salmonella spp. Specificity of the PCR method was confirmed with 48 Salmonella spp. and 5 non-Salmonella strains using invA gene primer. The average threshold cycle ($C_T$) of Salmonella spp. was $11.83{\pm}0.78$ while non-Salmonella spp. was $30.86{\pm}1.19$. Correlation coefficients of standard curves constructed using $C_T$ versus copy number of Salmonella Enteritidis ATCC 13076 showed good linearity ($R^2=0.993$; slope = 3.563). Minimum level of detection with the method was > $10^2$ colony forming units (CFU)/mL. These results suggested that the SYBR Green real-time PCR might be applicable for the specific detection of Salmonella spp. isolates.

Kaolin Separation Characteristics of the Disc Filters (디스크 필터의 카올린 분리특성)

  • Park, Hye Jung;Kim, Dae Chun;Kim, Hyung Sung;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.393-399
    • /
    • 2014
  • The permeation experiments were carried out to examine the separation characteristics of the modules which were piled up the disc-ring shape patterned membranes in this study. First of all, permeability of the pure water was measured for the self-made 5 shape disc filters, and varied from 0.25 to $2.24L/m^2{\cdot}hr{\cdot}bar$. The module showed the maximum pure water permeability was the maximum permeation flux, and the module showed the minimum pure water permeability was the minimum permeation flux for 0.1 wt% kaolin solution. However, all of the modules were not proportioned to the pure water permeability. Also, the backwashing was performed periodically for the module 1 in order to operate with 0.1 wt% kaolin solution for a long time. The most efficient operating condition was the 8 minute permeation and 2 minute backwashing cycle.