• Title/Summary/Keyword: Millimeter

Search Result 882, Processing Time 0.034 seconds

The Effects of calcium sulfate on healing of 1-wall intrabony defects in dogs (성견의 1면 골내낭에 calcium sulfate 이식이 치주조직 치유에 미치는 영향)

  • Suh, Hye-Yuhn;Choi, Seong-Ho;Moon, Ik-Sang;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.363-377
    • /
    • 1997
  • The main goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal diseases. Although conventional forms of periodontal therapy show sound clinical results, the healing results in long junctional epithelium. There have been numerous materials and surgical techniques developed for new attachment and bone regeneration. Bone grafts can be catagorized into: autografts, allografts, xenografts and bone substitutes. Synthetic bone substitute materials include hydroxyapatite, tricalcium phosphate, calcium carbonate, and Plaster of Paris. Calcium sulfate has found its use in dental practice for the last 30 years. Recent animal studies suggest that periodontal regeneration in 3 wall intrabony defect may be enhanced by the presence of calcium sulfate. And it is well known that 2 wall & 1 wall defect have less osteogenic potential, So we need to study the effect of calcium sulfate in 1 wall intrabony defect in dogs. The present study evaluates the effects of calcium sulfate on the epithelial migration, alveolar bone regeneration and cementum formation in intrabony defects of dogs. Four millimeter-deep one-wall intrabony defects were surgically created in the mesial aspect of anterior teeth and mesial & distal aspects of premolars. The test group received calcium sulfate grafts with a flap procedure. The control underwent flap procedure only. Histologic analysis following 8 weeks of healing revealed the following results: 1. The lengths of junctional epithelium were: 2.52mm in the control, and 1.89mm in the test group. There was no statistical significance between the two groups. 2. Alveolar bone formation were: 0.61mm in the control, and 1.88mm in the test group. There was a statistically significant difference between the two groups (p<0.05). 3. Cementum formations were: l.lmm in the control, and 2.46mm in the test group. There was a statistically significant difference between the two groups (p<0.05). 4. The length of CT adhesion were: O.97mm in the control, and 0.17mm in the test group. There was no statistically significant differences between the two groups These results suggest that the use of calcium sulfate in intrabony defects has little effect on junctional epithelium migration, but has significant effects on new bone and new cementum formations.

  • PDF

Effects of Adhesion Conditions on Bonding Strength of Pitch Pine Woods for Glued-Laminated Wood (리기다소나무 판재(板材)의 접착조건(接着條件)이 집성재(集成材)의 접착성능(接着性能)에 미치는 영향(影響))

  • Park, Sang-Bum;Kong, Young-To;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.48-53
    • /
    • 1988
  • This study was carried out to investigate the effects of pressing time and spreading amount, moisture content, gap-distance with butt to butt joint and adhesives on bonding strength in manufacturing the laminated wood with Pitch pine (Pinus rigida). The results obtained were as follows: 1) The pressing time of 12 hours, 10 kilogram per square centimeter of pressure and 200 gram per square meter of spreading amount were required to reach over 50 kilogram per square centimeter (block shear strength) in manufacturing the laminated wood by aqueous vinyl urethane adhesive. 2) The bonding strength decreased with the increase of moisture content of wood. The block shear strength, however, showed over 100 kilogram per square centimeter when the strength test was carried out after air-drying the laminated wood in high moisture content (30-70%). 3) Regardless of direction of load, every flexural property decreased with the increase of gap-distance with butt to butt joint. However, little of every flexural property was changed at 0.5 millimeter of joint-gap distance. The flexural property of vertically laminated wood (perpendicular to glue line to load direction: 1) showed more than that of horizontally laminated wood (parallel to glue line to load direction: //). 4) Among five adhesives used at this experiment, the bonding strength of aqueous vinyl urethane adhesive was the highest in dry bond and wet tests.

  • PDF

Analysis of Small Cell Technology Application for Performance Improvement in Simulation-based 5G Communication Environment (시뮬레이션 기반 5G 통신 환경에서 성능향상을 위한 스몰셀 기술 적용 분석)

  • Kim, Yoon Hwan;Kim, Tae Yeun;Lee, Dae Young;Bae, Sang Hyun
    • Smart Media Journal
    • /
    • v.9 no.2
    • /
    • pp.16-21
    • /
    • 2020
  • Recently, mobile traffic is increasing exponentially as major traffic is transferred to IoT and visual media data in the dissemination of mobile communication terminals and contents use. In order to overcome the limitations of the existing LTE system, 5G mobile communication technology (5G) is a technology that meets 1000 times data traffic capacity, 4G LTE system acceptance, low latency, high energy efficiency, and high cost compared to 4G LTE system. The path loss due to the use of the frequency domain is very high, so it may be difficult to provide a service compared to the existing 4G LTE system. To overcome these shortcomings, various techniques are under study. In this paper, small cell technology is introduced to improve the system performance of 5G mobile communication systems. The performance is analyzed by comparing the results of small cell technology application, macro communication and small cell communication, and the results of the proposed algorithm application for power control. The analysis results show that the use of small cell technology in the 5th generation mobile communication system can significantly reduce the shadow area and reduce the millimeter wave path loss problem.

Effect of MBCP block as carrier of rhBMP-2 in combination with ePTFE membrane on bone formation in rat calvarial defects

  • Shin, Chul-Woo;Cho, Kyoo-Sung;Jung, Sung-Won;Kim, Chang-Sung;Choi, Seong-Ho;Yun, Jeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.325-334
    • /
    • 2008
  • Purpose: The carrier used as delivery agent for bone morphogenetic proteins(BMPs) should also act as a scaffold for new bone formation. Moreover, bone formation should be predictable in terms of the volume and shape. This study examined the osteogenic effect of macroporous biphasic calcium phosphate (MBCP) block combined with ePTFE membrane as a carrier for recombinant human bone morphogenetic proteins (rhBMP-2). In addition, the additive effect of ePTFE membrane on bone formation was evaluated. Materials and Methods: Eight-millimeter critical sized calvarial defects were created surgically in 28 male Sprague-Dawley rats. The animals were divided into 2 groups containing 14 animals each. The defects were treated with either rhBMP-2/MBCP block (rhBMP-2/MBCP group) or rhBMP-2/MBCP block/ePTFE membrane (rhBMP-2/MBCP/ePTFE group). A disc-shaped MBCP block (3 mm height and 8 mm diameter) was used as the carrier for the rhBMP-2 and ePTFE membrane was used to cover the rhBMP-2/MBCP block. The histologic and histometric parameters were used to evaluate the defects after 2- or 8-week healing period (7 animals/group/healing interval). Results: The level of bone formation in the defects of both groups was significantly higher at 8 weeks than that at 2 weeks (P < 0.05). The ePTFE membrane has no additional effect compared with the rhBMP-2/MBCP block only. However, at 8 weeks, rhBMP-2/MBCP/ePTFE group showed more even bone formation on the top of the MBCP block than the rhBMP-2/MBCP group. Conclusion: These results suggest that the ePTFE membrane has no additive effect on bone formation when a MBCP block is used as a carrier for rhBMP-2.

Implementation of Gait Analysis System Based on Inertial Sensors (관성센서 기반 보행 분석 시스템 구현)

  • Cho, J.S.;Kang, S.I.;Lee, K.H.;Jang, S.H.;Kim, I.Y.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait analysis system to measure and analyze lower-limb movements. We developed an integral AHRS(Attitude Heading Reference System) using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE(Root Mean Square Error) of 1.08 and 1.72 degree in yaw and pitch angle. In order to evaluate the performance of our the gait analysis system, we compared the joint angle for the hip, knee and ankle with those provided by Vicon system. The result shows that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limb or gait analysis during the post-stroke recovery.

  • PDF

The Design, Development, and Measurement of Quasioptical system for Dual Channel SIS Receiver of 100-150GHz Band (100/150GHz 대역용 이중채널 SIS수신기의 준광학계 설계, 제작 및 측정)

  • Park, Jong-Ae;Han, Seog-Tae;Kim, Tai-Seong;Kim, Kwang-Dong;Kim, Hyo-Ryong;Chung, Hyun-Soo;Cho, Se-Hyung;Yang, Jong-Mann
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.7-18
    • /
    • 1999
  • We have designed and tuilt the quasioptical system for the dual channel receiver which is used for the simultaneous observation of the cosmic radio with 100GHz band and 150GHz band. The quasioptical system has been widely used to guide the beam for the millimeter and submillimeter waves. A Gaussian distribution of field and power transverse to their axis of propagation allow the simple and elegant theory of Gaussian quasioptics. Using the theory of Gaussian beam, we introduced the analysis of image beam which is applied for a wide range of frequency. In order to guide two beams from the Cassegrain antenna simultaneously, the quasioptical system and its components for the dual channel receiver were designed by using the image beam method. We have checked the characteristics of the quasioptical components and the system by using the heam measurement system, which is made by us. The quasioptical system has been installed in the dual channel receiver on the Cassegrain antenna. The performance of this system has been finally confimed through the successful simultaneous observation with two bands of the cosmic radio.

  • PDF

Design of 77 GHz Automotive Radar System (77 GHz 차량용 레이더 시스템 설계)

  • Nam, Hyeong-Ki;Kang, Hyun-Sang;Song, Ui-Jong;Cui, Chenglin;Kim, Seong-Kyun;Nam, Sang-Wook;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.936-943
    • /
    • 2013
  • This work presents the design and measured results of the single channel automotive radar system for 76.5~77 GHz long range FMCW radar applications. The transmitter uses a commercial GaAs monolithic microwave integrated circuit(MMIC) and the receiver uses the down converter designed using 65 nm CMOS process. The output power of the transmitter is 10 dBm. The down converter chip can operate at low LO power as -8 dBm which is easily supplied from the transmitter output using a coupled line coupler. All MMICs are mounted on an aluminum jig which embeds the WR-10 waveguide. A microstrip to waveguide transition is designed to feed the embedded waveguide and finally high gain horn antennas. The overall size of the fabricated radar system is $80mm{\times}61mm{\times}21mm$. The radar system achieved an output power of 10 dBm, phase noise of -94 dBc/Hz at 1 MHz offset and a conversion gain of 12 dB.

The effects of composit grafts of allogenic decalcified freeze Dried bone and calcium sulfate on the healing of 1-wall intrabony defects in dogs (성견의 1면 골내낭에서 탈회 냉동 건조골과 calcium sulfate 혼합이식이 치주조직 치유에 미치는 영향)

  • Suh, Jong-Jin;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.249-264
    • /
    • 1998
  • The present study evaluates the effects of calcium sulfate and DFDB on alveolar bone regeneration and cementum formation and connective tissue adhesion in intrabony angulated 1 wall defects of dogs. Four millimeter-deep angulated one-wall intrabony defects were surgically created in the mesial & distal aspects of premolars and with flap operaion alone(control group), with calcium sulfate(experimental group 1), with composit graft of 50% calcium sulfate and 50% DFDB(experimental group 2), with DFDB alone(experimental group 3). Histologic analysis following 8 weeks of healing revealed the following results: 1. The lengths of connective tissue adhesion was $1.05{\pm}0.48mm$ in the control, $1.30{\pm}0.67mm$ in the test group I, $0.97{\pm}0.22mm$ in the test group II and $0.93{\pm}0.15mm$ in the test group III. There was no statistical significance between control and all experimental groups. 2. Changes in alveolar bone level was $0.97{\pm}0.27mm$ in the control group, $1.45{\pm}0.42mm$ in the test group I, $2.00{\pm}0.33mm$ in the test group II, $1.88{\pm}0.34mm$ in the test group III. There was no statistically significant difference between control and experimental group I. There was a statistically significant difference between the control and experimental group II,III.(p<0.05). There was no statistically significant difference between all experimental group. 3. Cementum formation was $1.13{\pm}0.17mm$ in the control, $1.78{\pm}0.31mm$ in the test group I, $2.17{\pm}0.38mm$ in the test group II, $2.15{\pm}0.47mm$ in the test group III with statistically significant differences between control group and all experimental group(P<0.05). There was no statistically significant differences between all experimental group. These results suggest that the use of composit graft of 50% calcium sulfate and 50% DFDB and DFDB alone in angulated 1 wall intrabony defects has little effects on connective tissue adhesion, but has significant effects on new bone and new cementum formations.

  • PDF

The Effect of Negative electric field using charged PTFE membrane on Bone Healing of Rabbit Long Bone (Charged membrane에 의한 negative electric field가 토끼 장골의 골 치유에 미치는 영향)

  • Kwon, Yong-Su;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.551-562
    • /
    • 2004
  • The purpose of this study was to evaluate the effects of negatively electric field on bone healing in rabbit segmental long bone defects using negatively charged PTFE membrane. Ten millimeter segmental defects in the rabbit radius were used as the experimental model. After membranes were then charge injected using a corona-charging apparatus, the left defects were covered with non charged PTFE membranes as control groups, whereas the right defect was covered with negatively charged PTFE membranes as test group. The animals were divided into 4 groups of 2 rabbits each, and sacrificed at 2, 4, 6, and 8 weeks. Histomorphometric analysis showed a more newly formed bone in negatively charged membrane at early healing period. At 2 weeks, the proportion of new bone formation to total defect area was 0.32% in control group, 1.10% in experimental group. At 4 weeks, the proportion of new bone formation to total defect area was 6.86% in control, and 13.75% in experimental. At 6 and 8 weeks, no obvious difference was found between the two groups but newly formed bone in test groups were slightly more than that in control groups. In conclusion, negatively charged membranes showed more newly bone tissue than noncharged membranes at an early healing period. Although the number of samples was small, this study showed that the combination of negatively electrical stimulation and P1FE membrane may be of value in long bone healing.

Basic Analysis on Fractal Characteristics of Cement Paste Incorporating Ground Granulated Blast Furnace Slag (고로슬래그 미분말 혼입 시멘트 페이스트의 프랙탈 특성에 관한 기초적 분석)

  • Kim, Jiyoung;Choi, Young Cheol;Choi, Seongcheol
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2017
  • This study aimed to conduct the basic analysis on the fractal characteristics of cementitious materials. The pore structure of cement paste incorporating ground granulated blast furnace slag (GGBFS) was measured using mercury intrusion porosimetry (MIP) and the fractal characteristics were investigated using different models. Because the pore structure of GGBFS-blended cement paste is an irregular system in the various range from nanometer to millimeter, the characteristics of pore region in the different scale may not be adequately described when the fractal dimension was calculated over the whole scale range. While Zhang and Li model enabled analyzing the fraction dimension of pore structure over the three divided scale ranges of micro, small capillary and macro regions, Ji el al. model refined analysis on the fractal characteristics of micro pore region consisting of micro I region corresponding to gel pores and micro II region corresponding to small capillary pores. As the pore size decreased, both models suggested that the pore surface of micro region became more irregular than macro region and the complexity of pores increased.