• Title/Summary/Keyword: Micro Line

Search Result 617, Processing Time 0.032 seconds

Effect of Micro Surface Structure on Printed Electronics (미세표면구조가 전자인쇄에 미치는 영향)

  • Kim, Seung-Hwan;Kang, Hyun-Wook;Lee, Kyung-Heon;Sung, Hyung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.9
    • /
    • pp.20-25
    • /
    • 2010
  • The effect of micro surface structure on printing for printed electronics has been studied experimentally. The photolithography MEMS fabricationwass used to make a SU-8 molder which has micro structures on the surface, and the PDMS micro structure was fabricated by the PDMS molding method. In the aspect of printed electronics, we used silver paste conductive ink. We measured the surface energy variation on pillar microstructure. The microstructure was used to real printing experiment by a screen printing. We printed 1cm micro lines which have $30{\sim}250{\mu}m$ width, and checked the conductivity to sort out opened line pattern. Printability was defined by success probability of printed patterns and we found that the present microstructures improve the printability significantly.

An Investigation into Micro Valve Field and Flow Field Characteristic of 7mm Width (7mm폭의 Micro Valve 자장 및 유동특성 고찰)

  • Jeon, Y.S.;Kim, D.S.;Shin, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.657-658
    • /
    • 2006
  • Recently, the micro on-off valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for micro valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate micro on-off valve using the analogy of equivalent magnetic circuit and Finite Element Method(FEM) respectively. In case of poppet, flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump (미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측)

  • Ambrosia, Matthew Stanley;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

Application of Micro-Thin Laser sheet and Mixed Solvent for Micro-LIF Measurement in a Microchannel (마이크로 채널 내부의 Micro-LIF 측정을 위한 마이크로 레이저 평면빔과 혼합용매의 적용)

  • Yoon Sang Youl;Kim Jae Min;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.86-89
    • /
    • 2004
  • One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1$ to 3(3 or 5(5 pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Comparison of MicroRNA Expression in Placenta-derived Mesenchymal Stem Cells and Bone Marrow-derived Stem Cells (태반유래 줄기세포와 골수유래 줄기세포에서의 마이크로RNA 발현비교)

  • Kim, Soo Hwan
    • Journal of Life Science
    • /
    • v.24 no.11
    • /
    • pp.1238-1243
    • /
    • 2014
  • Mesenchymal stem cells (MSCs) have been widely used as cellular therapeutic agents. They have their own characteristic stemness, and thus, they can be used in the treatment of many chronic diseases and in anticancer therapy. MSC therapy has many advantages over chemical therapy. MSC therapy is based on self or homogeneous origin; as such, it is expected to be effective in the treatment of various diseases. In addition, microRNAs in particular have been studied for their structure and function, and they are also expected to prove effective for use as therapeutic agents in cancer or chronic diseases. MicroRNAs are largely associated with metabolism and homeostasis. Therefore, over- or under-expression of microRNAs leads to chronic diseases. Conversely, effective control of the expression of specific microRNAs reduces the risk of many chronic diseases. However, there have been no reports thus far on the synergistic effects of MSCs and microRNAs. Therefore, in this study, we examined the relationship between MSCs and microRNAs using placenta-derived MSCs (PDSCs), bone marrow-derived MSCs (BM-MSCs), and fibroblast (WI-38) cells. We studied the expression of some microRNAs in MSCs and compared the expression in each cell line and cell passage. As a result, we found that the expression of microRNA-34a was higher in PDSCs than in BM-MSCs and that the expression of microRNA-27a, 33a, 33b, and 211 was higher in BM-MSCs than in PDSCs. Therefore, we expect that each MSC line will be used as cell therapy, considering its expressed functional microRNA.

A Study on the Cutting Processes improvement of Micro-Spring by Finite Element Analysis (유한요소 해석을 이용한 마이크로 스프링의 전단공정 개선에 관한 연구)

  • 홍석관;전병희;김민건
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.421-426
    • /
    • 2003
  • Micro-suing that used on micro mechanism should be equal to distance between pitch and correct of shape. Therefore, micro spring must make by super-precision working. But, current step of super-precision processing depends on special quality of work piece and is ineffective the aspect of cost and productivity yet. Also, to use as demandable length shearing process perform but even if make precision spring, in the aspect of quality of coil spring make difficult that produce product of good quality. Therefore, purpose of this study presented proposed process that extract the point of processing factor after perform finite element analysis applying existing sheet shearing process to suing shearing process consider cost and productivity after evaluate.

  • PDF

A Study on the Argon Laser Assisted Thermochemical Micro Etching (레이저를 이용한 미세에칭에 관한 연구)

  • 박준민;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.844-847
    • /
    • 2001
  • The application of laser direct etching has been discussed, and believed that the process is a very powerful method for micro machining. This study is focused on the micro patterning technology using laser direct etching process with no chemical damage of the material surface. A new introduced concept of energy synergy effect for surface micro machining is the combination of chemically ion reaction and laser thermal process. The etchant can't etch the material in room temperature, and used Ar laser has not power enough to machine. But, the machining is occurred in local area of the material by the combined energy. Using this process, the material is especially prevented from chemical damage for electric property. We have tested this new concept, and achieved a line with $1{mu}m$ width. The Ar laser with 488nm wavelength was used. The material was Si(100) wafer, and etchant is KOH solution. The application and flexibility of this process is in great hopes for MEMS structures and fabrication of the micro electric device parts.

  • PDF

A study on fabrication of a micro patterned LGP (미세 패턴 응용 도광판 제작에 관한 연구)

  • Yoo Y.E.;Kim T.H.;Kim S.G.;Seo Y.H.;Je T.J.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.533-534
    • /
    • 2006
  • Micro pyramid pattern and its array are designed to enhance the brightness and its uniformity of LGP which is one of key parts in LCD. The designed micro pyramid patterns are fabricated on a Si-wafer first through MEMS process and then a Ni-stamper is electro-plated from the Si pattern master. Adopting the fabricated Ni-stamper, LGPs are injection molded at different mold temperatures and the fidelity of the pattern replication is estimated for each molding conditions and pattern locations. The replicated patterns are found to have some defect such as local short shot or micro weld line which are believed to have negative effect on the performance of the LGP.

  • PDF

A Study on the Analysis of Cycle Ratio Using Fractal Dimension in Al 2024-T3 (프랙탈 차원을 이용항 AL 2024-T3 합금의 피로수명비 해석에 관한 연구)

  • 조석수
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.1
    • /
    • pp.29-36
    • /
    • 2000
  • Surface micro-crack grows along intergranular or transgranular region of crystal grains. But if it meets the barrier such as sessile dislocation and precipitates it loses straightness and deflects. Investigators had many difficulties in estimating fatigue life of smooth specimen because of the random distribution growth and coalescence of surface micro-cracks. The path of surface micro-crack has irregularity due to nonhomogeneous microstructure. Euclidian geometry can't quantify the shape of surface micro-crack but fractal geometry can. Therefore in this paper fractal dimension is measured at various stage of cycle ratio and estimated cycle ratio in 2024-T3 aluminium, alloy.

  • PDF