• Title/Summary/Keyword: Method of Difference Analysis

Search Result 6,392, Processing Time 0.051 seconds

The Analysis on Inquiry Tendency of Elementary Science Textbooks by Curriculum Period: Focusing on the Comparison of Results of Previous Studies Using Romey's Method (초등 과학 교과서의 교육과정 시기별 탐구 성향 비교 분석: Romey 분석법을 이용한 선행 연구 결과 비교를 중심으로)

  • Myoung-Duk Jang
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.16 no.2
    • /
    • pp.166-181
    • /
    • 2023
  • The purpose of this study is to examine the change and appropriateness of inquiry tendency in elementary science textbooks by national curriculum period by comparing previous researches that reported Romey's Involvement Index in the science textbook and other subject textbooks. The results of the study are as follows: First, for the text index (T), the value of science textbooks by curriculum tends to continue to decline overall. The value of science textbook based on the 3rd curriculum is judged to be extremely inquiry oriented and the value of the textbooks based on the 2007 and 2015 revised curriculum are the values judged as somewhat authoritative textbook and as a textbook at the appropriate level of inquiry, respectively. There is no significant difference compared to the T values of other subject textbooks since the 2007 revised curriculum; Second, the index of figures and diagrams in the text (FD) of science textbooks also continues to decline by curriculum periods. In particular, the FD value of science textbook of the 2015 revised period is judged to be a authoritative textbook, which is lower than the value of other subject textbooks; Third, in the case of the activity index (A), it gradually decreases from the third curriculum to the 2015 revised curriculum, but it is judged as textbooks suitable for inquiry. However, after the 7th curriculum, the value of A is generally lower than those of other subject textbooks; Fourth, for the index of the questions at the ends of chapters (Q), the value of Q is reported to be extremely limited compared to the aforementioned three indices(T, FD and A), which may be mainly due to differences in the composition of science textbooks by curriculum period.

The effect of repeated firings on the color of zirconia-based all-ceramic system (반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향)

  • Jang, Jung-Eun;Kim, Mu-Hyon;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of repeated firings on the color of zirconia restoration with different shading method. Materials and methods: Three different types of zirconia frameworks (adding metallic pigments to the initial zirconia powder before sintering (Group NM), dipping the milled frameworks in dissolved coloring agents (Group KI), or application of liner material to the sintered white frameworks (Group KW) were used to support A3 shade dentin porcelain. Repeated firings (3, 5, or 7) were performed, color differences among ceramic specimens were measured using a colorimeter. Repeated measurements analysis of variance (ANOVA) was used to analyze the data for significant difference. The Tukey Honestly Significant Different (HSD) test was used to perform multiple comparisons (${\alpha}$ = .05). Results: 1. $L^*a^*b^*$ values of the ceramic systems were affected by the number of firings (1, 3, 5 or 7 firings) (P < .001) and shading methods (P < .001). 2. As the number of firings increased, the $L^*$ (for all groups) and $a^*$ value (for KW and NM groups) decreased and the $b^*$ value(for all groups) increased. 3. The mean color differences caused by repeated firings were perceptible (${\Delta}E$ > 1) for group KW and KI fired after 3 times, except for group NM fired after 7 times. 4. In order of decreasing ${\Delta}E$ value fired after 7 times, the values were group KI(${\Delta}E$ = 2.26) > group KW (${\Delta}E$ = 1.47) > group NM (${\Delta}E$ = 1.08) (P < .001). Conclusion: Repeated firings influenced the color of the zirconium-oxide all-ceramic specimens with different shading methods.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

The Comparison of Video Assisted Thoracic Surgery (VATS) with 10 mm Thoracoscopy to 2 mm Thoracoscopy for Primary Spontaneous Pneumothorax (원발성 자연 기흉에서 10 mm와 2 mm 비디오 흉강경 수술의 비교)

  • Hwang Jin-Wook;Jo Won-Min;Min Byoung-Ju;Son Ho-Sung;Lee In-Sung;Shin Jae-Seung
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.627-632
    • /
    • 2005
  • Background: The video-assisted thoracic surgery (VATS) with 2 mm thoracoscopy in primary spontaneous pneumothorax (PSP) was known to be unreliable in its accuracy and recurrence rate. We compared 10 mm VATS with 2 mm VATS in the results of operation. Material and Method: From Sept. 1998 to Dec. 2002, 176 cases (10 mm VATS; 73 cases, 2 mm VATS; 103 cases) of PSP were treated by VATS blob resection at Korea University Ansan Hospital. 10 mm thoracoscope, 5 mm port, and 5 mm instruments were used in 10 mm VATS group, and 2 mm thoracoscope, 2 mm ports and 2 mm instruments used in 2 mn VATS group. In the two groups, staples were inserted through 11.5 mm port for chest tube. Result: The mean follow-up duration was 20,8$\pm$16.1 months in 10 mm VATS group, and 13.9 $\pm$8.2 months in 2 mm VATS. The most common indication of operation was a recurrent pneumothorax ($34\%$) in 10 mm VATS and patient's desire ($40\%$) in 2 mm VATS, respectively. The operation time, number of staples used in operation, postoperative chest tube keeping days, postoperative total amount of drainage, and postoperative hospitalization days were statistically lower in 2 mm VATS. Other significant variables affecting the operation time in linear regression analysis were the number of staples that used in operation, the presence of pleural adhesion, and type of pleurodesis and thoracoscope used in operation. However, $R^2$ values were lower than 0.1. The postoperative recurrence rate was $2.7\%$ in 10 mm VATS and $2.9\%$ in 2 mm VATS. It was not significant statistically. Recurrent cases developed within 1 year in both groups but the difference was statistically insignificant. Conclusion: Although there were differences in follow-up duration between two groups, the operation time, number of staples that used in operation, postoperative chest tube keeping days, postoperative total amount of drainage, and postoperative hospitalization days were statistically lower in 2 mm VATS. And in 2 mm VATS, there were no technical difficulties during operation and no differences in recurrence rate from 10 mm VATS. As a result, we suggest that 2 mm VATS can be used in the treatment of PSP.

The Differences in Resting Pulmonary Function in Relation to the Nutritional status of Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자의 영양상태에 따른 안정시 폐기능 차이)

  • Mun, Yeung-Chul;Yu, Sung-Keun;Park, Hye-Jung;Park, Jong-Won;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Kim, Jung-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Background: With cases of chronic obstructive pulmonary disease(COPD), weight loss and low body weight have been found to correlate with increased mortality and poor prognosis. Therefore, nutritional aspects are an important part of the treatment in cases of COPD. In Korea, there is only limited data available for the changes of resting pulmonary function in relation to nutritional status. This study was carried out to investigate the differences of resting pulmonary function in relation to the nutritional status of patients with COPD. Method : 83 stable patients, with moderate to severe COPD, were clinically assessed for their nutritional status and resting pulmonary function. The patients' nutritional status was evaluated by body weight and fat-free mass (FFM), which was assessed by bioelectrical impedance analysis. According to their nutritional status, the 83 patients were divided into two groups, designated as the depleted, and non-depleted, groups. Result : Of the 83 patients, 31% were characterized by body weight loss and depletion of FFM, whereas 28% had either weight loss or depleted FFM. In the depleted group, significantly lower peak expiratory flow rate(p<0.05) and Kco(p<0.01), but significantly higher airway resistance(Raw, p<0.05) were noted. There was no difference for the non-depleted group in forced expiratory volume at one second, residual volume, inspiratory vital capacity, or total lung capacity. Maximal inspiratory pressure($P_{Imax}$) was also significantly lower in the depleted group(p<0.05). Conclusion : We conclude, from our clinical studies, that nutritional depletion is significantly associated with the change in resting pulmonary function for patients with moderate to severe COPD.

  • PDF

Biomass and Net Production of Pinus densiflora Natural Forests of Four Local Forms in Korea (한국산(韓國産) 4개(個) 지역형(地域型) 소나무 천연림(天然林)의 물질생산(物質生産)에 관(關)한 연구(硏究))

  • Park, In Hyeop;Lee, Seok Myon
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.2
    • /
    • pp.196-204
    • /
    • 1990
  • Pinus densiflora is not only widely distributed but also one of the most economically important timber species in Korea. In Korea, this species is classified into four local forms according to tree forms, as it has widely geographical variations. Trees of Ankang form are dwarfish nearly like shrubs, and those of Keumkang form are very tall and straight. Those of flatland and highland forms are exhibited in-between Ankang and Keumkang forms. This study was carried out to examine biomass, net production and production efficiency among four local forms of Pirzus densiflora forests growing in Korea. For the study, dimension analysis was used for trees and harvest method for shrubs and herbs in four 30-40 year-old stands showing the typical tree forms. Stand biomass of Ankang, flatland, highland and Keumkang forms were 29.87, 110.89, 133.53 and 205.42 t/ha, respectively. As going in order of Ankang, flatland, highland and Keumkang forms, the proportions of stem woods to total tree biomass increased while the proportions of stem barks, live branches, needles and roots showed a tendency to decrease. Stand net productions of Ankang, flatland, highland and Keumkang forms were 3.716, 10.796, 13.097 and 16.500 t/ha yr., respectively. As going in order of Ankang, flatland, highland and Keumkang forms, the proportions of stem woods and lire branches to total tree net production increased while the proportion of needles decreased. In case of live branches, the opposite trend of biomss and net production proportion may be resulted from the differences in the ratio of self-pruning. Net assimilation ratios of Ankang, flatland, highland and Keumkang forms were 1.406, 1.920, 1.487 and 1.677, respectively. Efficiency of needles to produce stems in those forms were 0.239, 0.714, 0.572 and 0.771, respectively. Considering the difference in measuring time, net assimilation ratio and efficiency of needles to produce stems may increase as going in order of Ankang, flatland, highland and Keumkang forms.

  • PDF

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

Re-Analysis of Clark Model Based on Drainage Structure of Basin (배수구조를 기반으로 한 Clark 모형의 재해석)

  • Park, Sang Hyun;Kim, Joo Cheol;Jeong, Dong Kug;Jung, Kwan Sue
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2255-2265
    • /
    • 2013
  • This study presents the width function-based Clark model. To this end, rescaled width function with distinction between hillslope and channel velocity is used as time-area curve and then it is routed through linear storage within the framework of not finite difference scheme used in original Clark model but analytical expression of linear storage routing. There are three parameters focused in this study: storage coefficient, hillslope velocity and channel velocity. SCE-UA, one of the popular global optimization methods, is applied to estimate them. The shapes of resulting IUHs from this study are evaluated in terms of the three statistical moments of hydrologic response functions: mean, variance and the third moment about the center of IUH. The correlation coefficients to the three statistical moments simulated in this study against these of observed hydrographs were estimated at 0.995 for the mean, 0.993 for the variance and 0.983 for the third moment about the center of IUH. The shape of resulting IUHs from this study give rise to satisfactory simulation results in terms of the mean and variance. But the third moment about the center of IUH tend to be overestimated. Clark model proposed in this study is superior to the one only taking into account mean and variance of IUH with respect to skewness, peak discharge and peak time of runoff hydrograph. From this result it is confirmed that the method suggested in this study is useful tool to reflect the heterogeneity of drainage path and hydrodynamic parameters. The variation of statistical moments of IUH are mainly influenced by storage coefficient and in turn the effect of channel velocity is greater than the one of hillslope velocity. Therefore storage coefficient and channel velocity are the crucial factors in shaping the form of IUH and should be considered carefully to apply Clark model proposed in this study.

Use of Respiratory Motion Reduction Device (RRD) in Treatment of Hepatoma (간암의 방사선치료 시 호흡운동 감소장치(respiratory motion reduction device, RRD)의 유용성에 관한 연구)

  • Lee Suk;Seong Jinsil;Kim Yong Bae;Cho Kwang Hwan;Kim Joo Ho;Jang Sae Kyung;Kwon Soo Il;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.319-326
    • /
    • 2001
  • Purpose : Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. Depending on the location of the tumor, the magnitude of PTV margin extends from 10 mm to 30 mm, which increases substantial volume of the irradiated normal tissue hence, resulting in increase of normal tissue complication probability (NTCP). We developed a simple and handy method which can reduce PTV margins in patients with liver tumors, respiratory motion reduction device (RRD). Materials and methods : For 10 liver cancer patients, the data of internal organ motion were obtained by examining the diaphragm motion under fluoroscope. It was tested for both supine and prone position. A RRD was made using MeV-Green and Styrofoam panels and then applied to the patients. By analyzing the diaphragm movement from patients with RRD, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using AcQ-Plan, a treatment planning software. Dose to normal tissue between patients with RRD and without RRD was analyzed by comparing the fraction of the normal liver receiving to $50\%$ of the isocenter dose. DVH and NTCP for normal liver and adjacent organs were also evaluated. Results : When patients breathed freely, average movement of diaphragm was $12{\pm}1.9\;mm$ in prone position in contrast to $16{\pm}1.9\;mm$ in supine position. In prone position, difference in diaphragm movement with and without RRD was $3{\pm}0.9\;mm$ and 12 mm, respectively, showing that PTV margins could be reduced to as much as 9 mm. With RRD, volume of the irradiated normal liver reduced up to $22.7\%$ in DVH analysis. Conclusion : Internal organ motion due to breathing can be reduced using RRD, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.