• 제목/요약/키워드: Mercury Lamp

검색결과 149건 처리시간 0.025초

Scanning of Mercury-free Flat Fluorescent Lamp(MFFL) for LCD Backlight

  • Seo, In-Woo;Jung, Jae-Chul;Oh, Byung-Joo;Kim, Hyuk;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.827-830
    • /
    • 2008
  • We proposed a new Mercury-free flat fluorescent lamp (MFFL) for LCD backlight which has the scanning ability to reduce the blurring edges of moving images. We expanded the single cell MFFL with 2.2 inch diagonal size into the multi-cell MFFL for the 32-inch LCD-TV backlight application, and examined its response characteristics and proposed a driving scheme for scanning.

  • PDF

Photooxidation of BR Vulcanizate Using High Pressure Mercury Lamp

  • Kim, Eunha;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제50권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Polybutadiene rubber (BR) has been well known that its physical and chemical properties are changed when it is exposed to ultraviolet light undergoing photooxidation. In this study, photooxdiation process of BR vulcanizate was investigated using a high pressure mercury lamp used as an outdoor lighting, which has high UV radiation efficiency and reasonable cost. Discoloration and crack formation of photooxdized BR vulcanite surface were examined using an image analyzer. Change of chemical functional groups of BR vulcanite surface by photooxidation was investigated using ATR-FTIR, and variation of the crosslink density with the UV irradiation time was investigated. By increasing the UV irradiation time, the crosslink density steeply increased after a period of time and did not increase any more. Formation of hydroxyl (~OH) and carbonyl (~C=O) groups on the BR vulcanizate surface increased and the1,4-cis unit was converted to the 1,4-trans unit as the photooxidation was proceeded.

분광 분석법에 의한 고압 수은등의 온도분포 측정 (Temperature Distribution Measurement of High-pressure Mercury Lamp using Spectroscopic Method)

  • 김상용;김창섭;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.13-18
    • /
    • 1989
  • Temperature distribution of 250W high-pressure mercury lamp has been measured by the spectroscopic method using relative intensities of spectral lines. To obtain radial temperature distribution, the measured intensity which was integrated along the line of sight was transformed into radial line intensity by Abel's inversion. Temperature was determined from relative intensities of spectral lines of the same atomic species. The measured temperature of 250W high-pressure mercury lamp is 6000K at the axis. In this experiment temperature profile of high-pressure arc is papabolic as known.

  • PDF

무수은 제논 EEFL의 전기적 특성 (Electric Properties of Mercury-free Xe EEFL)

  • 이성진;김남군;이종찬;박노준;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.650-657
    • /
    • 2007
  • This paper had mentioned about CCP light source application for increasing the efficiency of Xe lamp the mercury-free lamp. In order to increase the efficiency of Xe EEFL, we designed and manufactured the lamp used by mixture gas of Xe, Ne and He. Also, we have analyzed the electrical and optical properties with the firing voltage, sustain voltage, paschen's curve, wall charge, and capacitance. As a result, the firing voltage decreased by increasing the ration of mixture gas. and, It is owing to include the gas with high ionization energy. The firing voltage decreased in condition happening the penning effect, Because the ion of metastable state created from penning effect, Which can encourage the ionization phenomena. Also, the wavelength of 467.12 is increase. because of the energy transition in the wavelength of 147 nm. therefore, we can know about the affection of phosphor with UV emission properties. Through an experiment, Xe 100 % and Xe 75 % confirmed same spectrum properties by each mixture gas ratio. In the case of Xe 50 %, spectrum properties appeared Xe discharge and Ne-He discharge. That analyzed an electrical and optical properties. Therefore, confirmed that is excellent because properties of firing voltage, wall charge, capacitance in Xe 50 %, Ne : He = 9 : 1. We offered parameter in inverter manufacture and lamp manufacture by electrical and optical properties.

고압수은램프발광관의 시작연구 (The Trial Manufacturing of Inner Bulb of 200W High Pressure Mercurry Lamps)

  • 지철근
    • 전기의세계
    • /
    • 제19권2호
    • /
    • pp.18-20
    • /
    • 1970
  • Research on the domestic production of arc tube of high pressure mercury lamp. This research is to solve the problem on the domestic manufacturing method for the arc tube of high pressure mercury lamp. (200W). The trial product is favorably compared with its foreign equivalents in its performances and quality. An advancement in manufacturing technology and the strict selection of raw materials will assure its domestification.

  • PDF

LCD Backlight 용 무수은 형광램프의 제작 및 특성 분석 (Analysis of Fabrication and Characterization of free-Hg fluorescent lamp for LCD Backlight)

  • 이휘철;임성규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.237-240
    • /
    • 2000
  • It is expected that there will be the regulation for limiting the amount of Hg content in cold cathode fluorescent lamp (CCFL) for LCD backlight system. Now it is necessary to develop mercury-free backlight system. The mercury-free CCFL coated with PDP phosphors was fabricated and evaluated. The CCFL filled with Xe and Ne showed 4500 ㏅/$m^2$ with efficiency of 13 lm/W.

  • PDF

수은등을 이용한 인코히어런트 삼각 홀로그래피 (Incoherent Triangular Holography using Mercury Lamp)

  • 김수길
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.22-27
    • /
    • 2001
  • 기존의 인코히어런트 홀로그래피의 주요한 단점인 바이어스와 공액영상을 제거할 수 있는 변형 삼각 간섭계를 제시하였다. 또한, 제안된 방법을 이용한 인코히어런트 홀로그래피의 가능성을 입증하기 위하여 수은 램프를 이용하여 인코히어런트 홀로그램을 구성하고 이를 수치적 및 광학적으로 복원한 실험결과를 제시하였다.

  • PDF

모 수은폭로 사업장의 작업환경개선에 의한 근로자의 요중 수은 및 공기중 수은 농도의 추적조사 연구 (A Follow up Study on the Mercury Concentration in Air and in Urine of Workers after Implementing Controls of Work Environment in Mercury Vapor Exposed Industry)

  • 방신호;김광종;박종태
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.198-207
    • /
    • 1994
  • In order to evaluate the effectiveness of environmental intervention of work place, metal mercury concentration in air and in urine of the total 43 workers for 3years from December 1991 to October 1993 in a fluorescent lamp manufacturing industry exposed to mercury, was measured before and after implementation of controls such as establishing exhaust ventilation at the department of exhaustion, coating the floor of work place with epostane, cleaning of the floor, improved housekeeping, and etc. The results were as follows. 1. Before the intervention(December 1991) 39.0% exceeded metal mercury Threshold Limit Value(TLV, $0.05mg/m^3$). After the intervention(October 1993) 10.0% exceeded TLV and geometric mean of mercury in air was $0.1mg/m^3$, and showed effectiveness rate of intervention to be 74.4% 2. After the intervention, geometric means of mercury concentrations in air were 0.013, $0.019mg/m^3$ and showed effectiveness rate of intervention to be 76.6%, 65.5% in A factory(right tube lamp)and at exhaustion department, respectively, A follow up survey fround statistically significant reductions in mercury concetration in air three years later. 3. Mercury concentration in urine of 11 workers(29.7%) exceeded warning level of $100{\mu}l/l$ before the intervention. After the intervention, of 3workers(8.8%) exceeded warning level and geometric mean of mercury concentration($26.5{\mu}l/l$) in urine was 2.4 times than that of before the intervention. Geometric means of mercury concentrations in urine of workers at exhaustion department, at sealing and aging department were 44.0, $77.7{\mu}l/l$, respectively and they decreased 2.3, 3.2 times than that of before the intervention.

  • PDF

둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성 (Dependence of Round type electrodeless lamp according to ferrite core and cold spot temperature)

  • 오슬이;김남군;양종경;정영일;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.65-69
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of electrodeless lamp are related to ferrite core and cold spot temperature.

  • PDF