• 제목/요약/키워드: Medicine Code

검색결과 307건 처리시간 0.029초

Bell's Palsy 환자의 MMPI 특성에 관한 고찰 (Characteristics of MMPI Findings in Bell's Palsy)

  • 이아람;김헌일;박상동;황종순;성수민;조현석;김경호;김갑성;김근우
    • Journal of Acupuncture Research
    • /
    • 제21권1호
    • /
    • pp.59-69
    • /
    • 2004
  • Objective: The purpose of this study is to find the characteristics of MMPI in Bell's palsy patients. Methods: 40(21 male, 19 female) patients with Bell's palsy who visited Dept. of Acupuncture and Moxibustion, Bundang Oriental Medicine Hospital, Dongguk University completed a Minnesota Multiphasic Personality Inventory (MMPI)-383. The mean age was 43 years(range 18-72). MMPI scores were analyzed about validity scales, neurosis clinical scales, other clinical scales and by Two code method. Patients's MMPI scores were compared with Korean standard of MMPI. Results: The validity scales were within normal range. The neurosis clinical scales were within normal range. The other clinical scales were within normal range. The study of Two code method showed that D scale and Hy scale was higher than the other clinical scales. Bell's palsy patients's D scale and Hy scale means were higher than Korean standard of MMPI.

  • PDF

ICD-10 분류로 살펴본 저단계 레이저 치료 임상 논문 고찰 (The Clinical Indication of Low-Level Laser Therapy Using ICD-10)

  • 한현진;강기완;강세영;김락형;장인수
    • 대한한방내과학회지
    • /
    • 제36권4호
    • /
    • pp.561-569
    • /
    • 2015
  • Objectives The purpose of this study was to improve the knowledge of the low-level laser therapy (LLLT) field and to review research reports on LLLT to understand the current situation with respect to the clinical indication and current research trends.Methods A survey was carried out on the subject of low-level laser therapy to September 2012, using the PubMed search engine. Selected literature was checked by two reviewers and was classified according to the International Classification of Diseases 10th (ICD-10) over 10 years.Results We selected 469 studies in total, of which 142 were case reports, 118 were case-controlled trials, and 209 were randomized controlled trials of LLLT. According to the ICD-10 classification of diseases, the K code and M code being the most common, 399 studies have been published in the last 10 years. This shows that the study and clinical indications of low-level laser therapy have rapidly increased over the past 10 years.Conclusions Low-level laser therapy has been used most frequently with respect to dentistry and pain and musculoskeletal disorders. Recently, interest in and research into LLLT has increased for various diseases. With the establishment of standard conditions for low-level laser therapy, supported by aggressive clinical utilization and systematic clinical research, LLLT will be a very useful treatment and a useful alternative method in many medical fields.

BEAM 몬테칼로 코드를 이용한 Siemens Primus 선형가속기 다엽콜리메이터의 모델링 예비연구 (Preliminary Study of the Siemens Primus Linac MLC modelling using BEAM Monte Carlo code)

  • 정광호;서태석;조병철;박성호
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.29-32
    • /
    • 2004
  • 본 연구에서는 방사선치료장치의 몬테칼로 시뮬레이션에 널리 이용되는 BEAM 코드를 이용하여 Siemens사의 Primus 선형가속기 다엽콜리메이터(MLC)를 모델링한 후 그 적합성을 측정 데이터와의 비교를 통하여 검증하였다. 모델링을 위해 Primus 선형가속기의 다엽콜리메이터의 치수를 실측하였고 근사화를 통해 VARMLC 모듈을 사용하여 모델링하였다. 모델링 시에 leakage 및 tongue-and-groove 효과를 고려하였다. 시뮬레이션 결과는 필름 측정 결과와 잘 일치함을 확인하였으며, 본 연구에서의 방법이 Siemens 사의 다엽콜리메이터의 모델링에 유효함을 확인할 수 있었다.

  • PDF

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.

진단검사코드 표준화를 위한 LOCAL-LOINC 코드 매핑 시스템의 설계 및 구현 (A Design and Implementation of a LOCAL-LOINC Mapping System for the Standardization of a Laboratory Code)

  • 송혜주;안후영;박영호;김신영;김형회
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2008년도 한국컴퓨터종합학술대회논문집 Vol.35 No.1 (C)
    • /
    • pp.203-207
    • /
    • 2008
  • 본 논문에서는 의료기관의 검사코드인 LOCAL 코드(Local Code)를 LOINC 코드(Local Laboratory Result Code)와 매핑하기 위한 알고리즘을 구현하고, 이를 기반으로, LOCAL 코드의 매핑 및 입력을 지원하는 새로운 시스템을 제안한다. 이를 위해, 먼저, LOCAL 코드를 변환하여 LOINC의 여섯 가지 속성을 추출한 대응 코드로 생성한다. 추출한 대응코드는 LOINC 코드와 매핑하는 키 값이 된다. 대응코드와 LOINC 코드의 매핑은 각 속성을 우선순위에 따라 비교하는 과정을 포함하며, 매핑 결과 수에 따라 자동 매핑되거나, 상 하위 개념을 조합 또는 System 코드를 재검색하는 결과 최소화 단계를 수행한다. 본 연구에서는 매핑 알고리즘을 기반으로 LOINC 코드로 매핑 하고, 새로운 LOCAL 코드를 LOINC 코드로 입력할 수 있는 새로운 시스템을 구축하였다. 본 연구의 목표는 LOINC를 활용하여 방대한 진단검사 결과데이터를 표준화하고, 이를 통해 의료 기관 간 EMR을 실현하고 구축하는 기반요소를 마련하는데 있다. 본 연구를 통해, 국내 의료기관 간 검사 결과의 통합과 호환이 가능하게 할 것이며, 검사코드의 표준화를 위한 기반요소를 마련할 수 있을 것으로 기대한다.

  • PDF

사용자 수술명과 수술분류 code (ICD-9-CM) 일치율 향상에 관한 연구 (수술실 OCS program 사용 활성화를 통하여) (Study of matching user operation name and operation classification code (ICD-9-CM) (Through OCS program use facilitation at operating room))

  • 최향하;김미영;김도진;유지원;장정화;박수정;박재성
    • 한국의료질향상학회지
    • /
    • 제12권1호
    • /
    • pp.104-112
    • /
    • 2006
  • Background : The necessity of unify and standardize codes used at hospital has been emphasized since OCS (Order Communicating System) was adopted. Therefore, the purpose of this study were to standardize operation code by continuous training of the ICD-9-CM code that is used as standard code in OCS program at operating room. Method : In 400 operation data, operation code entered in OCS program at operating room was compared to operation name recorded in medical record. In addition, a matching rate between input data of operation code by medical record department and computing input data of operation code in 3,710 cases was compared for each department. User operation name and operation code were matched and major diagnosis by operation department and operation name were also matched. Results : User operation name was reflected in operation classification code in detail, and operation code entered on user was registered. Input rate and matching rate of operation code were gradually improved after improvement activity. In particular, a matching rate was high at ophthalmology where operation name is segmented. Plastic surgery and orthopedics with a lot of emergency operation and comprehensive operation name show low input rates. Conclusions : As the medical field makes progress in computerlization, awareness of information exchange and sharing becomes higher. Among codes to classified medical institution, codes related to surgical operation are all different by user of hospital and department. Computerlization and standardization is essential. And when efforts of standardization continue in alliance with individual hospital and institution, initiative of preparing medical policy data at a national level will be accelerated.

  • PDF

Monte Carlo Simulation of Small Photon Beam Measurements by Beam Intensity Scanner System(BISS)

  • Park, Kwangyl;Vahc, Young-Woo;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.282-284
    • /
    • 2002
  • We have developed and used BISS as a radiation detector to verify patient dose and determine the physical characteristics of beams used in Stereotatic Radio Surgery(SRS) and Intensity Modulated Radiation Therapy(IMRT). In order to confirm the function and accuracy of our BISS, we simulate our measurements by BISS under the radiation of 6MV photons from a Varian Clinac 21EX equipped with a 60 leaf pairs MLC. For the simulation based on the Monte Carlo algorithm, which remains the most comprehensive and accurate theoretical method to verify beam profiles, we use the BEAM code. Compared with the measurements by BISS, our simulation of variously shaped phantom measurements show good agreements. Our simulation results can be used as a theoretical standard to compare and confirm measurements by BISS and other dosimeters such as ultramicro cylindrical ionization chamber(UCIC) and radiographic film.

  • PDF

식육판매장 HACCP 선행요건의 효율적인 적용을 위한 비교분석 (Comparative analysis for improving the effective application of HACCP prerequisite items in meat markets)

  • 홍종해;나해서
    • 한국동물위생학회지
    • /
    • 제33권4호
    • /
    • pp.393-399
    • /
    • 2010
  • We analyzed the HACCP prerequisite of National Veterinary Research and Quarantine Service (NVRQS) and the Food Establishment Inspection Report of US Food and Drug Administration (FDA) to recommend contents and ranges to be complemented and used for preparation of guidelines for more effective application of HACCP prerequisites. We used the HACCP inspection reports implemented by Korea Livestock Products HACCP Accreditation Service from 2007 to 2009, FDA Food Code 2009 Guide 3-B Instructions for Marking the Food Establishment Inspection Report, and Retail Food Establishment Sanitation Requirements of 410 Indiana Administrative Code. Major non-compliance items were open doors and windows, insanitary cleaning of in-use utensil, inadequate record of warehousing, and improper storage, transportation, and labelling. Hot water supply, personal hygiene, and regular product testing were additional week points which should be more strongly controlled by detailed operating guidelines. Also, current prerequisite items were required revision into more precise contents to enhanced the effective evaluation and practical application in meat markets.

Modeling and experimental production yield of 64Cu with natCu and natCu-NPs in Tehran Research Reactor

  • Karimi, Zahra;Sadeghi, Mahdi;Ezati, Arsalan
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.269-274
    • /
    • 2019
  • $^{64}Cu$ is a favorable radionuclide in nuclear medicine applications because of its unique characteristics such as three types of decay (electron capture, ${\beta}^-$ and ${\beta}^+$) and 12.7 h half-life. Production of $^{64}Cu$ by irradiation $^{nat}Cu$ and $^{nat}CuNPs$ in Tehran Research Reactor was investigated. The characteristics of copper nanoparticles were investigated with SEM, TEM and XRD analysis. The cross section of $^{63}Cu(n,{\gamma})^{64}Cu$ reaction was done with TALYS-1.8 code. The activity value of $^{64}Cu$ was calculated with theoretical approach and MCNPX-2.6 code. The results were compared with related experimental results which showed good adaptations between them.