• Title/Summary/Keyword: Medical recorder

Search Result 43, Processing Time 0.026 seconds

Design of the Medical Thermal Array Printer Module Based on Microcontroller (마이크로 콘트롤러를 이용한 의료용 열전식 프린터 모듈의 개발에 관한 연구)

  • Lee, Myoungho;Kong, Inwook;Kwon, Hyukje
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.129-138
    • /
    • 1996
  • This paper describes design techniques of general purpose thermal array printer, especially easily applicable to medical measurement equipment. The'general'means that the proposed thermal array printer can be applied to not only medical field but other industrial field by establishing the eligible protocol. The thermal array printer is composed of i)MPU and its peripherals ii)printer head control, iii)diverse protection circuits, and iv)serial communication. In this paper the performance of the proposed thermal array printer was evaluated by applying to an 3 channel electrocardiogram recorder. The propped system can support'Hangul'text as well as alphanumeric characters and any bitmap image.

  • PDF

The Characteristic of the Obesity by Automatic Bioelectric Response Recorder (생체전기자율반응검사를 통한 저체중과 과체중의 특성 비교 연구)

  • Lee, Myeong-Jong;Han, Eul-Joo
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.2 no.1
    • /
    • pp.63-72
    • /
    • 2002
  • Objectives: The objectives of this study is the examination of physiology of the obesity by automatic bioelectric response recorder. Methods: The 86 patients below BMI 20 and the 144 patients over BMI 25 were objectives. They visited Dongguk University Kangnam oriental medical hospital from 2000. April 1 to 2001 August 30. Results :The patients below BMI 20 were accelerated a parasympathetic nerve and were decelerated a sympathetic nerve, so they loosened the tension, lacked the resistance and were oversensitive. The patients over BMI 25 were accelerated a sympathetic nerve and were decelerated a parasympathetic nerve, so they maintained the tension and the resistance.

  • PDF

A Clinical Study of Patients with Headache visited Neuropsychiatry (신경정신과(神經精神科)를 내원(來源)한 두통환자(頭痛患者)에 대한 임상적(臨床的) 고찰(考察))

  • Shim, Sang-Min;Heo, Seong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.11 no.1
    • /
    • pp.83-96
    • /
    • 2000
  • Objectives: In order to study the effect of the oriental medical therapy on the patients who visited Neuropsychiatry and oriental medical differentiation of symptoms and signs with ABR (Autonomic Bioelectric Response recorder)-2000, these clinical studies were performed. Methods: Sixty six patients with headache were classified into three groups; the first is tension headache, the second is migraine headache, the last is the others, each group was investigated of a various characteristic, the effect of the oriental medical therapy and stress was measured by ABR-2000. Result: 1. According to the statics, the tention headache's rate was higher than migraine; on the whole woman's rate was higher than man's. however in the migraine the rate of sex was equal. 2. According to the cause facter, oversensitiveness, overexertion, dyspepsia, etc. were numorous in the order. 3. According to the oriental medical differentiation of symptoms and signs, the rate of stagnation of the liver-qi' s fire-transmission(肝鬱化火) and deficiency of qi(氣虛), these two types were highest. result of analyzing ABR-2000 is that stagnation of the liver-qi's fire-transmission(肝鬱化火) is the highest stress. 4. According to treatment rate, 80.3 percent of patients satisfied of treatment.

  • PDF

A Study of Skin Resistance Variability of POF Patients by Autonomic Bioelectric Response Recorder (Centering around 1-3 Parts) (생체전기자율반응 측정기를 이용한 조기난소부전증 환자의 피부저항변이도 연구 (1, 2, 3 상한 중심으로))

  • Choi, Eun-Mi;Kang, Myung-Ja;Wee, Hyo-Sun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.3
    • /
    • pp.247-256
    • /
    • 2006
  • Purpose : To research the Skin Resistance Variability(SRV) of premature ovarian failure(POF) patients by Autonomic Bioelectric Response Recorder(ABR-2000 system, Meridian, Korea) and report the specific results in SRV of POF patients. Methods : We measured SRV of 17 POF Patients who came to Conmaul Oriental Medical Hospital during August 2005 ${\sim}$ July 2006 by ABR-2000 system. We analyzed the results which height of graph Part was converted into 0${\sim}$10, and the readings of Low/Normal/High. Results : The mean value of graph height on each(1, 2, 3) part is lower than normal range(4-6) in POF patients. The distribution ratio of Low/Normal/High on each(1, 2, 3) part shows that there are much more Low proportion in POF patients. Conclusion : The low graph height of POF patients on 1, 2, 3 part means that conductivity & capacitance of POF patients is low, especially on head.

  • PDF

Development of a Portable Cardiac Event Recorder (휴대용 심전도 이벤트 기록기 개발)

  • Chun, H.G.;Kim, H.C.;Lee, C.Y.;Kim, I.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.187-188
    • /
    • 1998
  • A low cost, low power, portable cardiac event recorder as a tether-free biological signal processor was developed. Dual channel ECG signals are sampled at 128Hz in 12 bits resolution. Sampled data are continuously recorded in a circular buffer. If event button is pressed, 2 minutes data before and after the event are recorded in 512 Kbyte SRAM. Total 11 events can be recorded. Data can be transferred to PC through RS-232 protocol. It operates for two months by a half AA size 3.6V Lithium battery. The system size is $55\times55\times13[mm^3]$.

  • PDF

A Study on Developement of Portable Digital Bio-signal Recorder (디지털 휴대용 생체 기록계 개발에 관한 연구)

  • Lee, H.J.;Chun, T.Y.;Yun, C.H.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.109-113
    • /
    • 1993
  • In this paper, we devised a simple portable digital recorder for a day life ECG signal recording. The system are consisted of ECG amp. part, signal conditioning part. A/D converter, data compression part and digital memory part. An ADPCM algorithm used at data compress part for 50% of data reduction. The maximum lengths of recording times take 3 hours in 1 mega byte memory.

  • PDF

A Study on the Patient Data Back-up System (환자 정보 back-up 시스템에 관한 연구)

  • 이윤선;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.155-160
    • /
    • 1984
  • In this paper, the patient data back-up system for medical and engineering field was designed. The system consists of 8-bit microprocessor, cassette recorder and data acquisition & control logic. To Inake data reduction, a Marked CORTES Algorythm which can be easily reconstructed was also designed in real time mode. In results, a Marked CORTES Algorythm produced about 35% data reduction rate and reconstructed good original data that are suitable Medician's reading.

  • PDF

Design of An Fair Non-Repudiation Protocol Using Digital Signature Recorder (전자서명 기록기를 이용한 공정한 부인방지 프로토콜의 설계)

  • Lee, Yong-Joon;Oh, Hae-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1345-1351
    • /
    • 2004
  • Due to the overwhelming importance the Internet gained nowadays, more and more sophisticated security services are requested. However many applications such as Internet Banking, Home Trading System, Electronic Medical Recede, electronic commerce, etc. are related to non-repudiation. Non-repudiation services are one of these new security requirements. ill comparison to other security issues, such as privacy or authenticity of communications, non-repudiation has not been studied intensively. Informally, we say that a protocol is fair if at the end of the protocol execution either originator receives a non-repudiation of receipt evidence and recipient receives a non-repudiation of origin evidence or none of them receives any valid evidence. The most non-repudiation protocols rely on a trusted third party(TIP) that has to intervene during each protocols run. the TIP may create a communication bottleneck. ill this paper, we suggest the digital signature recorder that guarantees fairness logically and supplies minimal network bottleneck to be composed verification server physically.

A Study on the Level of Medical Record Documentation and Agreement in the Information on the Patient's Past History (과거력 의무기록 정보의 기재정도 및 일치도 분석)

  • Seo, Jung-Sook;Yu, Seung-Hum;Oh, Hyohn-Joo;Kim, Yong-Oock
    • Korea Journal of Hospital Management
    • /
    • v.13 no.1
    • /
    • pp.42-64
    • /
    • 2008
  • This study was conducted to evaluate the quality in medical records by analyzing its completeness through setting up the level of record on the patient's past history and through examining the actual medial records. Targeting the information on the patient's past history in interns' records, residents' records and nurses' records toward 403 inpatients who were admitted first in 2004 at an university hospital due to stomach cancer. We analyzed whether the charts were recorded or not, recording level, the satisfaction with the expectant level of the records in the hospital targeted for a research and the level of agreement. The results were as follows; first, as for the rate of recording those each items, they were high in the chief complaint & present illness and the past illness history. Depending on the group of recorders, the recording rate showed big difference by items. Second, as a result of measuring the level after dividing the recording level of items for the patient's past history from Level 1 to Level 4 by each item, the admission history, the past illness history, and the family history were about Level 3, and the smoking history, the medication history, the chief complaint & present illness, the drinking history and allergy were about Level 2. In the admission department, it was excellent in the interns' records for the medical department. Third, as a result of its satisfactory level by comparing the expect level of a record and the actual record by item in information on the patient's past history, which was expected by the medical-record committee members of the hospital targeted for a study. And forth, we analyzed the level of agreement with Kappa score in the level of 'Yes' or 'None' related to the corresponding matter in Level 1, in terms of information on the past history in the intern's record, the resident's record, and the nurse's record. The level of agreement in the resident's record & the nurse's record, and in the intern's record & the resident's record was from "excellent" to "a little good". There were differences in the level of completeness and in reliability for the information on the past history by the recorder group or by the admission department. The encounter process that was performed by the admission department or the recorder group, indicated the result that was directly reflected on the quality of medical records, thus it was required further study about the medical record documentation process and quality of care. The items that showed the high recording rate quantitatively were rather low, consequently we'd should develop the tool for the qualitative inspection and evaluate the medical records further. And the items were needed to be detailed in the record level were rather low, and hence there needed to be a documentation guideline and education by the clinical departments.

  • PDF

Development of Telemetry ECG Modem(II) (원격 심전도 모뎀 개발에 관한 연구(II))

  • 김남현;고한우
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.179-184
    • /
    • 1988
  • In this study, we improve the performance of telemetry ECG modem using acoustic coupler. The results are as follows : (1) General active filter is replaced by SCF(switched capaciror filter) improving the LPF and BPF characteristics. (2) ECG Pre-amplifier is installed in ECG modem. (3) The interface circuit is designed to store the ECG waveform in casette recorder.

  • PDF