• Title/Summary/Keyword: Medical Instrument Design

Search Result 69, Processing Time 0.029 seconds

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

Development of the External Fixator for a Bone Fracture (골절치료용 체외고정기기 개발을 위한 연구)

  • 윤희열;한정수;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.317-322
    • /
    • 2002
  • In this paper, the problems of the external fixator that have developed for a distal radius fracture so far are analyzed, and accordingly, the characterizations, which must have a prototype, are arranged. C-Arm is used. This instrument makes it possible for the real play of the internal body by x-ray permeability. From this data. it is possible to induce important design factors Finally. a basic mechanism, which has to be applied, is decided, and the Solid Edge program, which uses a 3-D design tool, completes then total instrument design.

Development of lontophoresis System for Transdermal Drug Delivery (약물치료법의 개선을 위한 이온토포레시스 시스템의 개발)

  • 양경모
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.127-132
    • /
    • 1997
  • Recently there has been increased interest in the use of iontophoresis for the transdermal delivery of drugs, both ionic and nonionic. The use of iontophoresis has been rare over the years due to the lack of domestic supplies of the instrument and the expensive iontophoresis instrument made by foreign country. The purpose of this study was to design a commercially available iontophoresis system (WIT- 1 ). The efficacy of WT- 1 system was well defined. In clinical trial, procaine iontophoresis produced local anesthesia of significantly longer duration than swabbing and placebo groups. The 4% procaine iontophoresis using WIT-1 significant difference in anesthetic duration between WIT- 1 system and IontopherTM PM system. The result of this study suggest that WIT-1 system can be used for the transdermal delivery of drugs in various clinical conditions.

  • PDF

Continuum Mechanism with increased force and Optimal Design Method for Manually Controlled Endoscopic Surgical Instrument (수동 조작 내시경 수술 도구를 위한 힘이 증가된 연속체 메커니즘 및 이의 최적 형상 설계)

  • Lee, Hoyul;Jung, Euisung;Jeong, Yoosoo;Park, Young-Sang;Song, Chanho;Son, Jaebum
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.164-171
    • /
    • 2021
  • This paper proposes a continuum mechanism for manually controlled endoscopic surgical instruments. The wire-driven mechanism is typically adapted for endoscopic surgical tools because motors cannot be embedded to the joints due to the size limitation. However, the conventional wire-driven mechanism has inherent problems caused by redundancy, such as deflection and low precision. It does not have operating force and manipulability for surgery. Therefore, a method to increase the force of the continuum mechanism using a multi-wire with simple mechanical structure is proposed. Moreover, for intuitive operation, a hand-controller mechanism that can manipulate the length of the wire without complex process is proposed. Finally, we show that the proposed mechanism and methods are applicable to endoscopic surgical tools through simple experiments.

Construction of a new questionnaire for assessing physical therapy student attitudes towards their education and profession and testing its validity and reliability

  • Tedla, Jaya Shanker
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.20-25
    • /
    • 2017
  • Objective: During the physical therapy education, if we can understand the student's attitude then we can make valuable suggestions with respect to the teaching in the universities and professional employment in the country. The aim of the current study is to develop a questionnaire to test the physical therapy students' attitudes towards their education and profession and to test its test-retest reliability and content validity. Design: Cross-sectional study. Methods: A total of 47 physical therapy students who were in their final year were randomly selected to participate in the study. After the making of the questionnaire, it was given to 6 professional experts teaching in the field of physical therapy to obtain their responses for each question with a 5-point Likert scale grading. Their answers were used in making the content validity of the questionnaire. Afterwards, the physical therapy students were asked to fill the questionnaire. Instrument reliability and test-retest reliability were also assessed by having the students complete the questionnaire after one month of taking the questionnaire. Results: The content validity index was 0.71 for the whole scale and values of individual subdivisions were ranging from 0.69 to 0.75. Instrument reliability measured by Cronbach's alpha coefficient was 0.86 for the whole scale and subdivision values were ranging from 0.32 to 0.86. Test-retest reliability was assessed by intraclass correlation coefficient, which was 0.71 for whole scales and subdivision values were ranging from 0.38 to 0.70. Conclusions: This questionnaire, which assesses the physical therapy student attitude towards their education and profession, has good content validity, instrument reliability, and test-retest reliability.

Program design of the education subject curriculum by the department of emergency medical technology based on National Competency Standards key competencies (NCS 직업기초능력 기반 응급구조(학)과 교양 교과목 편성 연구)

  • Hong, Sung-Gi;Koh, Bong-Yeun;Kim, Soo-Tae
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.3
    • /
    • pp.37-47
    • /
    • 2016
  • Purpose: The purpose of the study was to establish an education curriculum subject program design for the department of emergency medical technology based on National Competency Standards (NCS) key competencies. Methods: A self-reported questionnaire was completed by 180 level 1 emergency medical technicians in K area from June 15 to 20, 2016. Except for 14 incomplete questionnaires, 141 data were analyzed. The study instrument included general characteristics of the subjects (7 items) and importance and satisfaction levels for 10 key competencies including 34 items of subfactors by a Likert 5-point scale using Borich Needs Assessment Model. A locus for focus model (LF model) was used to derive the top priority key competencies for the education curriculum. Data were analyzed by SPSS v. 20.0. Results: The order of education needs of the program included interpersonal competency (1.442), communication competency (1.384), problem solving competency (1.185) and professional ethics competency (1.149). In the LF model, the required jey competencies included interpersonal competency, communication competency, professional ethics competency, and problem solving competency. Conclusion: The study results coincided with standard education curriculum guidelines. Our resluts can provide a valid reference for the department of emergency medical technology.

Psychometric Evaluation of Uterine Cervical Cancer Screening Embarrassment Questionnaire among Korean Women: Complementary Use of Rasch Model

  • Cho, Eun-Jung;Chung, Bok-Yae;Lee, Kwan;Consedine, Nathan S.;Lee, Won-Kee
    • Women's Health Nursing
    • /
    • v.17 no.5
    • /
    • pp.463-473
    • /
    • 2011
  • Purpose: Cervical cancer can be prevented by regular cervical screening. Embarrassment has been reported as one important barrier to cervical screening uptake. The absence of appropriate instrumentation, however, has limited our understanding of the links between embarrassment and health care outcomes. The purpose of this study was to evaluate psychometric attributes of the uterine cervical cancer screening embarrassment questionnaire. Methods: A convenience sample for field study was recruited from four gynecological clinics in Gyeongju, Korea. Within a cross-sectional descriptive design, 339 women who had cervical screening completed self-administered measures of embarrassment including a visual analogue, general medical embarrassment, dispositional embarrassment, and Pap smear related negative emotion. Results: Rasch analysis of items demonstrated the evidence of one-dimensional construct and good 7-point rating scales functioning. Factor analysis revealed that uterine cervical cancer screening embarrassment was comprised of two domains-bodily manifestations and perceiving an undesirable social face. Construct validity was demonstrated by a high subscale-to-subscale correlation. Convergent and discriminant validity was evidenced by significant correlations with a 100 mm VAS scale, general medical embarrassment, and Pap smear related negative emotion. Known-group validity was established by comparing women with high versus low trait embarrassment. Both two sub-scales and overall scale demonstrated good internal reliability. Conclusion: The Uterine uterine cervical cancer screening questionnaire is a reliable and valid instrument suited to assessing the manifestations of embarrassment during screening. The use of instrument can be extended to understand the client's embarrassment undergoing health examinations which require the exposure of their private parts.

A Review on the paradiam of Eyewear Design Concept (안경 design concept의 paradigm에 관한 고찰)

  • Kang, Hyunshik;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.189-195
    • /
    • 2004
  • Eyewear must not be judged only by the skill of the designer who created it. For production of successful eyewear, we must always take into account the point of view of the wearer. Because eyewear is above all a means to correct of the visual acuity, it is a medical instrument. Therefore in any case, it should not submit to the dictatorship of fashion designer. The eyewear designer's role may therefore be summarized in following way: to have a subtle sensitivity and inspiration, and originality, know-how to develop a symbiosis between functionality and technical know-how, harmonious production of the design and concept of the human engineering. At present, the way of designing has undergone a big change to enabling us to supply the customer with technical design and rapid prototyping of eyewear with assistance to computer processing such as computer graphic and cad/cam.

  • PDF

Design of Irrigation Pumping System Controller for Operational Instrument of Articulation (관절경 수술을 위한 관주(灌注)시스 (Irrigation Pumping System) 제어기의 개발)

  • 김민수;이순걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1294-1297
    • /
    • 2003
  • With the development of medical field, many kinds of operations have been performed on human articulation. Arthroscopic surgery, which has Irrigation Pumping System for security of operator vision and washing spaces of operation, has been used for more merits than others. In this paper, it is presented that the research on a reliable control algorithm of the pumping system instrument for arthroscopic surgery. Before clinical operation, the flexible artificial articulation model is used for realizing the model the most same as human's and the algorithm has been exploited for it. This system is considered of the following; limited sensing point, dynamic effect by compliance, time delay by fluid flow and so on. The system is composed with a pressure controller, a regulator for keeping air pressure, an airtight tank that can have distilled water packs, artificial articulation and a measuring system, and has controlled by the feedback of pressure sensor on the artificial articulation. Also the system has applied to Smith Predictor for time delay and the parameter estimation method for the most suitable system with both the experiment data and modeling. In this paper, the pressure error that is between an air pressure tank and an artificial articulation was measured so that the system could be presumed and then the controller had developed for performing State-Feedback. Finally, the controller with a real microprocessor has realized. The confidence of system can be proved by applying this control algorithm to an artificial articulation experiment material.

  • PDF