• Title/Summary/Keyword: Mechanical Alignment

Search Result 345, Processing Time 0.024 seconds

Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments (방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작)

  • Cha, Dong-Soo;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

Robot-assisted Long Bone Fractures Realignment

  • Xu, W.L.;Mukherjee, S.
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.91-97
    • /
    • 2005
  • Bones are dynamic structures, being supported by muscles, tendons, and ligaments. When some or all the structures are disturbed i.e. in fractures, the alignment of the bone in respect to the rest of the body is deranged. This gives rise to axial as well as rotational deformity in three dimensional planes. The correct alignment and position of the long bones are to be maintained to heal the bone in the best possible anatomical and functional position. The objective of this research is to address the problems in the current practice involving surgeon, assistant, fluoroscopy and crude mechanical means and to see if a robotic solution exists to solve the problems of manipulating and reducing long bone fractures. This paper presents various design aspects of the proposed surgeon-instructed, image-guided and robotic system including the system design specification, robot design and analysis, motion control and implementation, and x-ray image processing and incorporation in CAD environment.

  • PDF

A New Method for Measuring Azimuthal Anchoring Energy of Rubbed and UV-Exposed Polyimide Alignment Layers

  • Park, H.J.;Lee, W.K.;Kim, D.G.;Shin, D.C.;Woo, J.W.;Shin, H.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1619-1621
    • /
    • 2007
  • Novel optical measurement systems and improved cell configurations for measuring of azimuthal anchoring energies were developed. The difference between the mechanical rubbing direction and the optical easy axis that caused errors in the previous azimuthal anchoring energy measurement was compensated. In addition, the measurement accuracy of the twist angle and therefore the azimuthal anchoring energy was greatly enhanced. As a result, we were able to obtain valid azimuthal anchoring energy values for different alignment layers.

  • PDF

Development of Seesaw-Type CSP Solder Ball Loader (CSP용 시소타입 로딩장치의 개발)

  • Lee, J.H.;Koo, H.M.;Woo, Y.H.;Lee, C.W.;Shin, Y.E.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.873-878
    • /
    • 2000
  • Semiconductor packaging technology is changed rapidly according to the trends of the micro miniaturization of multimedia and information equipment. For I/O limitation and fine pitch limitation, DIP and SOP/QFP are replaced by BGA/CSP. This is one of the surface mount technology(SMT). Solder ball is bumped n the die pad and connected onto mounting board. In ball bump formation, vacuum suction type ball alignment process is widely used, However this type has some problems such as ionization, static electricity and difficulty of fifo(first-input first-out) of solder balls. Seesaw type is reducing these problems and has a structural simplicity and economic efficiency. Ball cartridge velocity and ball aligned plate angle are Important variables to improve the ball alignment Process. In this paper, seesaw-type CSP solder ball loader is developed and the optimal velocity and plate angle are proposed.

  • PDF

Total Knee Arthroplasty (슬관절 전 치환 성형술)

  • Lee, Dong-Chul;Sohn, Wook-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Total knee arthroplasty has become a common procedure for treatment of severe osteoarthritis, rheumatoid arthritis and post-traumatic arthritis. In the past, failure of total knee arthroplasty was commonly attributable to aseptic loosening, often associated with component malalignment, soft tissue imbalance. With improved surgical instrumentation and soft tissue balancing techiniques, failure secondary to mechanical loosening has been minimal. But surgeons are still dissatisfied with implant malalignment. Correct tibiofemoral alignment seems to be particularly important since it is generally agreed that axial deviation and imprecise implantation may lead to loosening of the implant component. Navigation systems and robotic techniques could potentially solve problems of imprecision in traditional total knee arthroplasty. It is expected that the success rate and longevity of total knee arthroplasty will be improved during the twenty first century.

  • PDF

Pose alignment control of robot using polygonal approximated gripper images (다각 근사화된 그리퍼 영상을 이용한 로봇의 위치 정렬)

  • Park, Kwang-Ho;Kim, Nam-Seong;Kee, Seok-Ho;Kee, Chang-Doo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.559-563
    • /
    • 2000
  • In this paper we describe a method for aligning a robot gripper using image information. The region of gripper is represented from HSI color model that has major advantage of brightness independence. In order to extract the feature points for vision based position control, we find the corners of gripper shape using polygonal approximation method which determines the segment size and curvature of each points. We apply the vision based scheme to the task of alignment of gripper to reach the desired position by 2 RGB cameras. Experiments are carried out to exhibit the effectiveness of vision based control using feature points from polygonal approximation of gripper.

  • PDF

Fabrication of Porous Materials having an Anisotropic Thermal Conductivity through the Alignment of Plate-shaped Pores (배향된 판상 기공구조를 통해 열전도도 이방성을 갖는 다공질 재료의 제조)

  • Yun, Jung-Yeol;Song, In-Hyeok;Kim, Hae-Du
    • 연구논문집
    • /
    • s.33
    • /
    • pp.147-155
    • /
    • 2003
  • In order to fabricate porous materials having an anisotropic thermal conductivity by aligning plate-shaped pores structure, alumina powder (AM-21, mean particle size $4\mum$) and flake crystalline graphite was used. The aligned pore structure was realized using multi-pressing process. Degree of pore orientation increased with the number of pressing and thermal conductivity, parallel to the pressing direction, decreased with the number of pressing. Thermal conductivity decreased significantly to the addition of 30vol% crystalline graphite, however, in the case of 60vol%, thermal conductivity did not decrease significantly due to the breakage of crystalline graphite. An anisotropy of the thermal conductivity increased with the content of crystalline graphite up to 30vol%. Graded pore structure was fabricated by controlling the content and size of crystalline graphite, which provides, possibly, the enhancement in mechanical strength and thermal insulation properties of the insulating bricks.

  • PDF

The Characteristics of Photo-alignment with Photo-crosslinkable Polyimide (광 가교성 폴리이미드의 광배향 특성)

  • Shin, Dong-Muyng;Cho, Sun-Ju;Shon, Byoung-Choung;Choi, Jeong-Woo;Yi, Mi-Hie;Choi, Kil-Yeoung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 1999
  • Photo-crosslinkable polyimide(PI) which contains CF3 moiety was synthesized. Polarized UV light transformed ketone group of PI to hydroxyl group, which was confirmed by IR and UV-visible spectroscopy. We investigated the dichroic UV-absorption before and after photo-reaction with linearly polarized light. In particular we have attempted to clarify the relationship between the anisotropy of surface region and surface azimuthal anchoring energy and knew that the anchoring energy of photo-alignment PI is comparable with that of mechanical rubbing.

The Effect of Electrical Characteristics and Electrode Shape on Alignment of Multi-walled Carbon Nanotubes (전기장 특성과 전극 형상이 다중벽 탄소나노튜브 정렬에 미치는 영향)

  • Kwon, Se-Hun;Jeong, Young-Keun;Jung, Chang-Sik;Kang, Myung-Chang;Lee, Hyung-Woo
    • Journal of Powder Materials
    • /
    • v.17 no.4
    • /
    • pp.326-335
    • /
    • 2010
  • In this paper, the effect of electrical characteristics and electrode shape on the alignment and attachment of multi-walled carbon nanotubes (MWNTs) has been studied. The attraction and alignment of MWNTs between the gaps has been investigated by applying electric field which is called electrophoresis and dielectrophoresis. According to the frequency of electric field, positive or negative dielectrophoretic force can be determined. The concentration of MWNTs solution was $5\;{\mu}g/ml$, and a droplet of $1.0{\sim}1.5\;{\mu}l$ was dropped between two electrodes. Through the repeated experiments, the optimal electrical conditions for aligning and attaching MWNTs in the desired places were obtained. Since the frequency range of 100 kHz~10 MHz generated positive dielectrophoretic force, MWNTs were attracted and aligned between the gaps with this frequency range. For generating enough force to attract MWNTs, the appropriate voltage range was $0.3{\sim}1.3\;V_{rms}/{\mu}m$. Furthermore, the effect of electrode shape on the alignment of MWNTs was investigated. A single MWNT attachment was accomplished on the round shaped with 70% yield.

Precise Prediction of Optical Performance for Near Infrared Instrument Using Adaptive Fitting Line

  • Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyoung;Oh, Heeyoung;Yuk, In-Soo;Park, Chan;Chun, Moo-Young;Oh, Jae Sok;Kim, Kang-Min;Lee, Hanshin;Jeong, Ueejeong;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Infrared optical systems are operated at low temperature and vacuum (LT-V) condition, whereas the assembly and alignment are performed at room temperature and non-vacuum (RT-NV) condition. The differences in temperature and pressure between assembly/alignment environments and operation environment change the physical characteristics of optical and opto-mechanical parts (e.g., thickness, height, length, curvature, and refractive index), and the resultant optical performance changes accordingly. In this study, using input relay optics (IO), among the components of the Immersion GRating INfrared Spectrograph (IGRINS) which is an infrared spectrograph, a simulation based on the physical information of this optical system and an actual experiment were performed; and optical performances in the RT-NV, RT-V, and LT-V environments were predicted with an accuracy of $0.014{\pm}0.007{\lambda}$ rms WFE, by developing an adaptive fitting line. The developed adaptive fitting line can quantitatively control assembly and alignment processes below ${\lambda}/70$ rms WFE. Therefore, it is expected that the subsequent processes of assembly, alignment, and performance analysis could not be repeated.