• Title/Summary/Keyword: Measuring parameters

Search Result 1,230, Processing Time 0.036 seconds

Influence of Temperature on the Photosynthetic Responses of Benthic Diatoms: Fluorescence Based Estimates (온도가 저서규조류 광합성 반응에 미치는 영향: 형광을 이용한 추정)

  • Yun, Mi-Sun;Lee, Choon-Hwan;Chung, Ik-Kyo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.2
    • /
    • pp.118-126
    • /
    • 2009
  • Benthic diatoms are very important primary producers in understanding estuary ecosystems and their productions are largely varied by their photo-physiological characteristics. The short-term effects of increased temperature on the photosynthetic and photo-physiological characteristics of cultured different species of benthic diatoms (Navicula sp., Nitzschia sp., Cylindrotheca closterium, and Pleurosigma elongatum) were investigated by measuring their PSII-fluorescence kinetics using a Diving-PAM. Photosynthesis versus irradiance curves were measured every two hours at six different temperatures (10, 15, 20, 25, 30, and $35^{\circ}C$) for twenty-four hour. The effective quantum yield of PSII ($\Phi_{PSII}$) for most of the species showed a decreasing trend with increased temperature. The relative maximum electron transport rate (rETRmax) was significantly increased up to the optimum temperature level and then sharply decreased. Relative to the values of other parameters, the maximum light use coefficient ($\alpha$) was not substantially changed at lower temperature levels (<$30^{\circ}C$) but significantly decreased only at higher temperatures (30 and $35^{\circ}C$). The light saturation coefficient ($E_K$) mirrored the rETRmax temperature response. In regards to the temperature acclimation abilities of the four species with time, Navicula sp. and C. closterium acclimated to short-term changes in temperature through their photo-physiological adjustments.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

An Effect of the Self-Regulation Program for Hypertensives -Synthesis & testing of Orem and Bandura's theory- (본태성 고혈압 환자의 자가간호증진을 위한 자기조절 프로그램 효과 -Orem이론과 Bandura이론의 합성과 검증-)

  • Park, Young-Im;Hong, Yeo-Shin
    • Research in Community and Public Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.109-129
    • /
    • 1994
  • Chronic health problems has become a major concern and challenge to the health care professionals today. Especially hypertension, one of the leading primary cause of death in Korea, is a typical chronic disease requiring adequate and continuous management. Though these hypertensives need to maintain desirable health practice by themselves for their life time, many previous studies indicated that most of the essential hypertensives have no specific symptoms and thus, reluctant to follow appropriate medical regimens causing the condition further aggravated and complicated. Self-care is an essential factor that keeps chronic patients in control of their health and wellness. Thus this study was conducted to identify the effect of the comprehensive self-regulation program as a nursing intervention on the promotion self-care performance and improvement in physical parameters of hypertensives. For this purpose, a one group quasi-experimental research with pre and post test design was used. The subjects of the study was consisted of thirty persons with mild or moderate essential hypertension from two companies in Cheong-ju city. The whole program was carried out from October, 1993 to February, 1994. The self-regulation program was consisted with group education on hypertension and self-care, self-regulation including the blood pressure self-monitoring and recording, recording of daily self-care activities, and encouraging and reinforcing self-efficacy through verbal persuation and enactive attainment. The subjects were asked to measure their own blood pressure by themselves twice per day and to record blood pressure and the daily self-care performance according to the instructions provided during the whole period of 9 weeks. The instruments used for data collection in this study were as follows : 1) Instruments used for measuring the knowledge about hypertension, multiple health locus of control, and perceived benifits and barriers were adapted from previous studies and modified by author to be fit for the subjects. 2) Self-efficacy scale and self-care performance record were developed by the author. 3) Physiological parameters included systolic / diastolic blood pressure, body weight, level of blood cholesterol, and 24hour ambulatory blood pressure. The post-experimental Cronbach's Alpha as the reliability test of scales were 0.703-0.897, an appropriate level of confidence. The effect of the program was analyzed by experimental stages ; the first week, the fifth week, and the ninth week since the experimental imput began. Data were analyzed by the SPSS PC+ program with paired t-test and t-test, repeated measure ANOVA, and pearson's correlation to de termine the effect of program. The results were as follows : 1) After the self-regulation program, scores on knowledge(t=-2.41, p=.011), perceived self-efficacy (F=5.60, p=.001), self-care performance(F=22.31, p=.0001) were significantly higher than those before the program. 2) After the program, both systolic and diastolic blood pressure were significantly lower than those before the program(F=10.89 -13.11, p=.0001). However in 24hour ambulatory blood pressure, systolic mean pressure was nearly significantly lower, but not in diastolic mean pressure. 3) After the program, the body weight was significant decresed(t=5.53, p=.0001), but the blood cholesterol level was not decreased significantly except in those cases with higher cholesterol level. 4) There were significant relationships between changes in self-care performance and diastolic pressure at 1st week (r=.3389, p=.033) and changes in self-care performance and systolic pressure at 9th week(r=.3651, p=.024). 5) There were significant relationship between perceived self-efficacy and self-care performance at 5th week(r=.5313, p=.001) and 9th week (r=.3026, p=.052). 6) After the program, internal health locus of control and perceived benefits did not show significant change, but perceived barriers was significantly lower than those before the program (t=3.57, p=.0001). From the above results, it can be concluded that 1) The self-regulation program is an effective nursing strategy to promote self-care performance of hypertensives and to lower the blood pressure. Thus this program can be recommended in the management of the hypertensives in workplaces and community settings. 2) The synthesis of Orem's self-care theory and Bandura's self-regulation & self-efficacy theory in this study was proved to enhance explanation and prediction of the change of self-care behavior. Thus the result of the study would contribute in development of the self-care theory and an expansion of practice-theory.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Growth and Yield Related Characteristics of Soybeans for the Estimation of Grain Yield in Upland and Drained-Paddy Field (콩 논.밭 재배에서 수랑예측을 위한 생육과 수량 관련 형질의 비교)

  • Cho, Young-Son;Park, Ho-Gi;Kim, Wook-Han;Kim, Sok-Dong;Seo, Jong-Ho;Shin, Jin-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.7
    • /
    • pp.599-607
    • /
    • 2006
  • The experiments were carried out to develop simulation model for estimating the yield of soybean in upland and paddy field condition. Field experiments were done at National Institute of Crop Science in 2005. The evaluated soybean cultivars were Taekwangkong, Daewonkong, and Hwangkeumkong. Soybean seeds were planted by hill seeding with 3-4 seeds and row and hill spacing were $60{\times}10cm$ in upland and $60{\times}15cm$ in paddy field. Seeds were sown on row (without making ridge) and on the top of ridge in upland and paddy field, respectively. Field parameters were measured yield components ($plants/m^{2}$, pod no./plant, and 100-seed weight, seed yield and growth characteristics (stem length, leaf area at each stage, and dry weight of shoot) and after measuring they were compared the relationships with seed yield and yield components and seed yield and growth characteristics. Seed yield of soybean was affected by cultivars and planting density. Seed yield was higher in upland than paddy field due to the higher planting density in upland field. The upland soybeans generally had lower 100-seed weight than that of paddy field. Seed yield of soybean in a paddy field was greatest in Taekwangkong and followed by Daewonkong and Hwangkeumkong. The harvest index of taekwangkong and Hwanggumkong was higher in upland than paddy field, however, it was higher in paddy field than upland in Daewonkong. Seed yield was greatest in Daewonkong in both experimental fields. The greatest stem length was observed in taekwangkong and Hwanggumkong (R6) in late growth stage in paddy field. Dry weight of shoot and pod, pod number, stem length, and stem diameter were higher grown in paddy field than grown in upland. Crop growth rate (CGR) of cultivars was higher in paddy field after 8 WAS(weeks after sowing) and it was greatest at 13 WAS in Daewonkong among the cultivars. In upland field, CGR was greatest in Taekwangkong and then followed by Daewonkong and Hwanggumkong during 12 and 15 WAS. There was no significant relationships between 100-seed weight and seed yield in both experimental fields. A significant positive relationship was observed between seed number and seed yield. The correlation coefficients between leaf area and shoot dry weight were about 0.8 during the whole growth stage except 5 WAS and 4-5 WAS in paddy field and upland, respectively. This experiment was done just one year and drained paddy field condition was not satisfied drained condition successfully at 7th leaf age of soybean by the heavy rain, so we suggest that the excessive soil water reduced seed yield in paddy field and the weather condition should be considered for utilizing of these results.

Development of High Meat Quality Using Microsatellite Markers in Berkshire Pigs (Microsatellite Marker를 이용한 육질 우수 버크셔 계통 조성에 관한 연구)

  • Lee, Yong-Hwa;Kwon, Seul-Gi;Park, Da-Hye;Kwon, Eun-Jung;Cho, Eun-Seok;Bang, Woo-Young;Park, Hwa-Chun;Park, Beom-Young;Choi, Jong-Soon;Kim, Chul-Wook
    • Journal of Animal Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.89-97
    • /
    • 2011
  • In this study, the efficiency of microsatellite (MS) markers for pork quality was examined and further, their suitability to domestic pork industry also was verified, by measuring meat quality parameters of Berkshire breeds. A total of 323 pigs of Berkshire breeds were slaughtered and subjected to meat quality evaluation. In addition, the genomic DNAs from blood samples of slaughtered pigs were used for genotyping analysis of 50 MS markers. The results revealed that Berkshire breeds have excellent meat quality, compared with the popular domestic breeds such as Duroc, Yorkshire, and Landrace. Noticeably, the Berkshire breeds exhibited a significant post-mortem pH24hr ($5.88{\pm}0.01$) and fat content ($2.878{\pm}0.06$). Through the linkage analysis between MS markers, 14 MS markers showed significant association with meat quality traits (p<0.05). Maximum significant differences of 0.55 pH24hr value and 2.04% fat content were observed between the highest and lowest allele populations. If these 14 MS markers are applied to the pork quality diagnosis kit, the synergistic effect can be expected in meat quality parameters such as meat color, fat content, pH 24 hr, cooking loss, drip loss and water-holding capacity.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Clinical Impact of Bronchial Reactivity and Its Relationship with Changes of Pulmonary Function After Asthmatic Attack Induced by Methacholine (기관지 반응성의 임상적 의의 및 메타콜린으로 유도된 천식 발작시 폐기능 변화와의 관계)

  • Ryu, Yon-Ju;Choi, Young-Ju;Kwak, Jae-Jin;Lee, Ji-A;Nam, Seung-Hyun;Park, Chang-Han;Chaon, Saon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.24-36
    • /
    • 2002
  • Background: Bronchial reactivity is known to be a component of airway hyperresponsiveness, a cardinal feature of asthma, with bronchial sensitivity, and is increments in response to induced doses of bronchoconstrictors as manifested by the steepest slope of the dose-response curve. However, there is some controversy regarding methods of measuring bronchial reactivity and clinical impact of such measurements. The purpose of this study was to evaluate the clinical significance and assess the clinical use by analyzing the relationship of the bronchial sensitivity, the clinical severity and the changes in pulmonary function with bronchial reactivity. Method: A total of 116 subjects underwent a methacholine bronchial provocation test. They were divided into 3 groups : mild intermittent, mild persistent, moderate and cough asthma. Severe patients were excluded. Methacholine PC20 was determined from the log dose-response curve and PC40 was determined by one more dose inhalation after PC20. The steepest slope of log dose-response curve, connecting PC20 with PC40, was used to calculate the bronchial reactivity. Body plethysmography and a single breath for the DLCO were done in 43 subjects before and after methacholine test. Results: The average bronchial reactivity was 38.0 in the mild intermittent group, 49.8 in the mild persistent group, 61.0 in the moderate group, and 41.1 in the cough asthma group. There was a weak negative correlation between PC20 and bronchial reactivity. A heightened bronchial reactivity tends to produce an increased clinical severity in patients with a similar bronchial sensitivity and basal spirometric pulmonary function. There were significant correlations between the bronchial reactivity and the initial pulmonary function before the methacholine test in the order of sGaw, Raw, $FEV_1$/FVC, MMFR. There were no correlations between the bronchial sensitivity and the % change in the pulmonary function parameters after the methacholine test. However, there were significant correlations between the bronchial reactivity and the PEF, $FEV_1$, DLCO. Conclusion: There was weak significant negative correlation between the bronchial reactivity and the bronchial sensitivity, and the bronchial reactivity closely reflected the severity of the asthma. Accordingly, measuring both the bronchial sensitivity and the bronchial reactivity can be of assistance in assessing of the ongoing disease severity and in monitoring the effect of therapy.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

Diagnostic Value of Procalcitonin and C-Reactive Protein in Differentiation of Pleural Effusions (흉수의 감별에 있어서 procalcitonin과 C-반응성단백의 유용성)

  • Kim, Sang-Ha;Park, Joo Young;Park, Hyun Sook;Seo, Hee Seok;Kim, Shin Tae;Kim, Chong Whan;Lee, Bu Ghil;Lee, Seok Jeong;Lee, Shun Nyung;Noh, Jin Kyu;Lee, Min Su;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.4
    • /
    • pp.353-361
    • /
    • 2007
  • Background: Malignancies are a common and important causes of exudative pleural effusions. Several tumor markers have been studied because the pleural fluid cytology and pleural biopsy specimens do not provide a diagnosis in a high percentage of malignant effusions. In an attempt to overcome this limitation, procalcitonin and C-reactive protein (CRP) in pleural effusions and serum, which are known to be inflammation markers, were measured to determine if they can differentiate an exudate from trasndate as well as the diverse causes of exudative pleural effusion. Methods: 178 consecutive patients with pleural effusion (malignant 57, tuberculous 51, parapneumonic 31, empyema 5, miscellaneous benign 7, transudative 27)were studied prospectively. The standard parameters of pleural effusion and measured serum and pleural procalcitonin were examined using in immunoluminometric assay. The level of CRP in serum and pleural fluid was determined by turbidimetric immunoassay. Results: The pleural procalcitonin levels in the exudate were significantly higher than those in the transudate, $0.81{\pm}3.09ng/mL$ and $0.12{\pm}0.12ng/mL$, respectively (p=0.007). The pleural CRP levels were significantly higher in the exudate than the transudate, $2.83{\pm}3.31mg/dL$ and $0.74{\pm}0.67mg/dL$, respectively (p<0.001). The pleural procalcitonin levels in the benign effusion were significantly higher than those in the malignant effusion, $1.15{\pm}3.82ng/mL$ and $0.25{\pm}0.92ng/mL$, respectively (p=0.032). The pleural CRP levels were significantly higher in the benign effusion than in the malignant effusion, $3.68{\pm}3.78mg/dL$ and $1.42{\pm}1.54mg/dL$, respectively (p<0.001). The pleural procalcitonin levels in the non-tuberculous effusion were significantly higher than those in the tuberculous effusion, $1.16{\pm}3.75ng/mL$ and $0.13{\pm}0.37ng/mL$, respectively (p=0.008). Conclusion: Measuring the level of procalcitonin and CRP in the pleural fluid is helpful for differentiating between transudates and exudates. In addition, it is useful for differentiating between benign and malignant pleural effusions.