• 제목/요약/키워드: Measuring control standard

검색결과 200건 처리시간 0.037초

GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS)

  • 김진영;김종상;김민경;이재일;서용준;인문교
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

수경배양액 무기성분농도 측정장치 개발 (Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution)

  • 허정욱;박경훈;홍승길;이재수;백정현;박종택;이승기
    • 한국환경농학회지
    • /
    • 제39권4호
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.

연구 실험실 내 국소배기장치의 제어풍속 평가 사례 (Case Study on the Evaluation of Capture Velocity of Local Exhaust Ventilation System in a Laboratory)

  • 임대성
    • 한국산업보건학회지
    • /
    • 제34권3호
    • /
    • pp.189-192
    • /
    • 2024
  • Objectives: To protect researchers using chemicals, it is necessary to monitor whether the working environment is well managed through the performance evaluation of the local exhaust system in the research laboratory. These results need to be reflected in the work environment management policy of research laboratories in the future. Methods: By measuring the capture velocities of fume hoods and arm hoods, which are the most commonly used local exhaust systems in research laboratories in a domestic research institute, we tried to confirm the degree to which the actual capture velocity values and legal standards were satisfied. The capture velocities were measured using a hot wire wind speedometer (TSI 9565-P, USA, 2016 with all exhaust systems in operation in the laboratory. As for the measurement position for each local exhaust system, in the case of the fume hood, the wind speed in the center of the opening surface was measured after opening 50% of the door of the hood. For the arm hood the capture velocities were measured at a distance of 10 cm vertically from the opening surface of the hood Conclusions: The total number of arm hoods measured was 546, and the average capture velocity was 0.61 m/sec with an S.D of 0.49. Among them, 99 satisfied the capture velocity standard of 1m/sec, meaning only 18.1% of the total satisfied with the standard. The total number of fume hoods measured was 625, and the average control wind speed was 0.48 m/sec with an S.D. of 0.17. Among them, the number of fume hoods that satisfied the capture velocity standard of 0.4 m/sec was 518, meaning 82.9% of the total satisfied the standard. Therefore, research institutes that operate local exhaust systems to protect researchers from chemicals should further strengthen the capture velocity management of hoods, and government agencies need to reflect this in work environment management policies based on further evaluation results.

공공서비스시설에서의 시설성능 요인에 대한 탐색적 연구 (Exploratory approach to measuring facility performance in public service facilities)

  • 이소영;신희용
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.284-287
    • /
    • 2009
  • In order to plan and manage public facilities effectively and efficiently, it is necessary to diagnose the current status of facilities and decide the objective features. Performance measurement is to provide managers with the information they need to measure competitive advantages. This paper discusses public facility performance in order to establish the conceptual framework for performance measurement for public facilities. In order to develop the measurement of public facility performance, a pilot study was conducted with facilities managers of facilities management corporation of public districts in Seoul. We investigated how public facilities management teams have assessed their performance and collected data regarding financial aspects, service aspects, community aspects, and building aspects. There is no standard format to measure facility performance since building sizes, programs, community needs widely differ. However, it is necessary to have a more consistent system to measure facility performance. In addition, each public municipal district needs to empower each district facilities management corporation to participate in managerial decisions and budget control.

  • PDF

Remote Measurement of ECU Self-Diagnostic Signal based on the Windows CE

  • Lee, Seong-Cheol;Yun, Yeo-Hung;Se, Ji-Won;Kwon, Tae-Kyu;Lee, Young-Chun;Jang, Bong-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.68.2-68
    • /
    • 2002
  • The purpose of this paper is to monitor ECU's self-diagnostic signal without wire. In order to measure the ECU's self-diagnostic signal, the interfaced circuit is developed to communicate ECU with a designed display terminal according to the ISO, SAE regulation of communication protocol standard. An 80C196KC processor is used for communicating ECU's self-diagnostic signal and communication data are sent to PDA monitoring system that is based on the Windows CE. Software on PDA is developed to monitor the ECU's self-diagnostic signal in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self-diagnostic signals are verified to mo...

  • PDF

공압서보밸브 KS규격 정립에 관한 연구 (A Study of Korean (Industrial) Standards for Pneumatic Servo Valve)

  • 김동수;이원희;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1231-1234
    • /
    • 2003
  • Pneumatic servo valve which is widely applied in industrial world is advanced technology compounded with electric, electronic and machine. And It is consist of Linear Force Motor. Spool Commutation Mechanism and Microprocessor. In this study, we accomplished test method of Linear Force motor test, Static characteristic test, Dynamic characteristic test for KS(Koran industrial standard) of Pneumatic servo valve. we accomplished study about the main item of Static characteristic test which is related to unload flow characteristic test. And Dynamic characteristic test was step input test and frequency response test. Specially about frequency response test, There was a difficulty resulting from the time delay problem caused by the basic compressibility of air. In order to solve the problem in this study. we proposed two methods. First, displacement of the servo valve spool was directly measured by using a laser sensor. Second, method of calculating control flow by measuring pressure and temperature of chamber.

  • PDF

시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성 (Characteristics of Bond Strength with Measuring Methods of Concrete)

  • 장흥균;김성환;홍창우;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF

시차 굴절률 측정에 의한 실시간 글루코오스 모니터링 (Real-time Monitoring of Glucose Using a Differential Refractive Index Detector)

  • 정진갑;이명희;최은경
    • 한국염색가공학회지
    • /
    • 제16권2호
    • /
    • pp.47-51
    • /
    • 2004
  • A differential refractive index detector was used for monitoring glucose contents in textile processing solutions. The sensitivity of the device was high enough to measure 0.05% aqueous glucose solution that could not be measured by normal refractive index measurement. The device was set to monitor glucose concentration continuously in real time by measuring differential refractive index and calibrated by standard glucose solutions in a range of 0.1 to 1.0%. The possibility of industrial application of the device was demonstrated by real-time monitoring of glucose concentration in textile processing solutions such as desizing bath and cellulase treatment bath. Both of solutions contained glucose as a major degraded product. The device would be able to control the weight loss of cellulosic fiber during cellulase treatment since the amount of degraded products in a processing bath is proportional to its weight loss.

Fishtail Edge를 이용한 OTF 측정장치의 자동화 (Automation of an OTF measurement system using a fishtail edge)

  • 김태희;최옥식;조현모;이윤우;이인원
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.7-13
    • /
    • 1997
  • 기존에 제작된 칼날주사형 OTF 측정장치의 물체부와 상분석부를 개선하여 측정을 자동화함으로써 MTF 측정 정확도를 향상시켰다. 여러 가지 크기를 갖는 핀홀과 슬릿들을 물체로 사용하였고, fishtail edge를 상분석부의 수평방향에 45.deg로 부착시킴으로써 radial과 tangential 방향의 MTF를 동시에 측정할 수 있도록 하였다. 또한 상분석부의 스텝핑 모터 구동장치와 측정 컴퓨터 프로그램을 개선하였고, SIRA 그룹의 50nm 표준렌즈를 사용하여 OTF 측정장치의 측정 정확도를 평가하였다.

  • PDF

유아의 학습관련 사회적 기술과 문식성 발달과의 관계 (Relationships Between Learning-Related Social Skills and Literacy Development of Young Children)

  • 안선희;권희경
    • 아동학회지
    • /
    • 제26권4호
    • /
    • pp.173-188
    • /
    • 2005
  • To examine relationships between learning-related social skills(LRSS) and literacy development a sample of 167 children aged 5-6 years were selected from 3 preschools in Seoul. Instruments for measuring LRSS were the cooperation, assertion, and self-control scales of the Social Skills Rating System (Gresham & Elliott, 1990) and the mastery behaviors scales of the Child Behavior Rating Scale (Bronson, et al. 1990). Literacy development was measured by the Concepts about Print(Woon, 1999), the Learning Readiness Scale(Korean Educational Development Institution 1998), and the Writing Development Scale(Lee, 1997). Teachers rated children's LRSS. Data were analyzed by mean, standard deviation, t-test, bivariate correlation, and regression analysis. LRSS correlated with children's literacy development. Mastery behaviors were the best predictor of literacy development.

  • PDF