• 제목/요약/키워드: Measurement Reliability

Search Result 2,418, Processing Time 0.07 seconds

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

Development of Korean Osteoarthritis Impact Measurement Scale(KAIMS) : from data collection to item development in the first study (한국형 골관절염영향측정도구 개발 - 자료수집에서 1차 문항개발까지 -)

  • Yi, Seung-Ju;Kim, Yeon-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose : The aim of this study was from data collection to item development in the first study before developing a valid and reliable instrument reflecting Korean's own language expression and culture. Methods : The fist survey was 140 osteoarthritis(OA) patients in 2 Cites was studied from November to December 2009. Open-ended questionnaire was decided 39 items from the first open survey. Questionnaire on the Korean Osteoarthritis Impact Measurement Scale(KAIMS) was recruited 2 professors and 5 physical therapists. Second survey was applied to 133 OA patients. Results : OA patients's average age${\pm}$standard deviation was $66.08{\pm}11.10$ years. The internal consistency reliability of 3 items. As estimated by Cronbach's alpha coefficient(${\alpha}$), was high(range, 0.86~0.96). 0.43~0.91 ${\alpha}$ coefficient for the internal consistency reliability of item-each scale was also high. However, item-discriminant validity on 3 items was low(${\alpha}$, 0.92~0.97). The construct validity by factor analysis was a little low. Conclusion : This study revealed that we confirmed a generation for 39 items on KAIMS reflecting Korean's own language expression and culture. Also, those of reliability were a little high. And, we will have to study the last instrument development (3rd study) by more subjects in the future.

  • PDF

Investigation of Various Reliability Indices of Pre-service Mathematics Teachers' Teaching Aptitude and Personality Test based on Setting Cut Scores (예비수학교사의 교직 적성·인성 검사에서 분할점수 변화에 따른 다양한 신뢰도 탐색)

  • Kim, Sungyeun
    • The Mathematical Education
    • /
    • v.57 no.1
    • /
    • pp.55-74
    • /
    • 2018
  • The purpose of this study is first to examine the relative influence of each error source and to investigate the optimal measurement conditions to ensure satisfactory multiple reliability coefficients based on the teaching aptitude and personality test for pre-service teachers. Participants were 33 students enrolled in mathematics education in a graduate school of education located in the Seoul metropolitan area from 2013 to 2017. The main results were as follows. First, the estimated variance due to residual was highest, followed by nesting of items within domains, graduate students, interactions of graduate students with domains, and domains. Second, total 96 items, with 12 domains containing 8 items in each domain, with cut score of 598, and original 210 items, with 14 domains containing 15 items in each domain, with cut scores of 615 or 716 were optimal measurement conditions to reach acceptable reliability levels based on the joint consideration of dependability coefficients, cut score dependability coefficients, adjusted dependability coefficients, and standard errors of measurement. Third, larger deviations between the arithmetic mean and the cut score indicated higher reliability coefficients of the test results. Finally, this study suggests ways for practitioners to consider how to apply generalizability theory for criterion-referenced tests and how to develop future research based on limitations.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

Measuring plagiarism in the second language essay writing context (영작문 상황에서의 표절 측정의 신뢰성 연구)

  • Lee, Ho
    • English Language & Literature Teaching
    • /
    • v.12 no.1
    • /
    • pp.221-238
    • /
    • 2006
  • This study investigates the reliability of plagiarism measurement in the ESL essay writing context. The current study aims to address the answers to the following research questions: 1) How does plagiarism measurement affect test reliability in a psychometric view? and 2) how do raters conceive the plagiarism in their analytic scoring? This study uses the mixed-methodology that crosses quantitative-qualitative techniques. Thirty eight international students took an ESL placement writing test offered by the University of Illinois. Two native expert raters rated students' essays in terms of 5 analytic features (organization, content, language use, source use, plagiarism) and made a holistic score using a scoring benchmark. For research question 1, the current study, using G-theory and Multi-facet Rasch model, found that plagiarism measurement threatened test reliability. For research question 2, two native raters and one non-native rater in their email correspondences responded that plagiarism was not a valid analytic area to be measured in a large-scale writing test. They viewed the plagiarism as a difficult measurement are. In conclusion, this study proposes that a systematic training program for avoiding plagiarism should be given to students. In addition, this study suggested that plagiarism is measured reliably in the small-scale classroom test.

  • PDF

Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry- (3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교-)

  • Paek, Kyung-Ja;Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

Real-time 3-Dimensional Measurement of Lumbar Spine Range of Motion using a Wireless Sensor (무선 센서를 활용한 요추 가동 범위의 실시간 3차원 측정)

  • Jeong, Woo-Hyuk;Jee, Hae-Mi;Park, Jae-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.713-718
    • /
    • 2012
  • Lumber spine range of motion has been used to measure of physical and functional impairment by various tools from a ruler to 3D kinematic devices. However, pre-existing tools have problems in either movement or accuracy and reliability limitations. Accurate devices are limited by fixed space whereas simple devices are limited in measuring complex movements with less accuracy. In order to solve the location, movement and accuracy limitations at once, we have developed a novice measurement device equipped with accelerometer sensor and gyroscope sensor for getting three-dimensional information of motion. Furthermore, Kalman filter was applied to the algorithm to improve accuracy. In addition, RF wireless communication was added for the user to conveniently check measured data in real time. Finally, the measurement method was improved by considering the movement by a reference point. An experiment was conducted to test the accuracy and reliability of the device by conducting a test-retest reliability test. Further modification will be conducted to used the device in various joints range of motion in clinical settings in the future.

The Study on the Thrust Measurement System of Low Thrust Liquid Rocket Engine (저추력 액체로켓엔진의 추력 측정 장치에 대한 연구)

  • Lee, Dong-Hyeong;Lee, Yang-Suk;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.55-59
    • /
    • 2008
  • It is very difficult to measure an accurate thrust for the performance test of liquid rocket engine. Liquid rocket engine is attached to the propellant feed system, control valve and many other safety systems. Without considering these effects, thrust data measured from the firing test is not reliable and meaningless. In this research, the modified thrust measurement system, which includes both all these side effects is developed for the verification of low thrust liquid rocket engine performance. In addition, reliability appraisal technique is studied to secure the reliability of thrust measurement system.

  • PDF