DOI QR코드

DOI QR Code

Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교-

  • Paek, Kyung-Ja (Dept. of Clothing & Textiles, Pusan National University) ;
  • Lee, Jeong-Ran (Dept. of Clothing & Textiles, Pusan National University)
  • Published : 2008.01.31

Abstract

Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

Keywords

References

  1. 남윤자, 최경미, 정의승, 윤명환. (2004). Size Korea 3차원 인체측정방법 표준화. 패션정보와 기술, 1, 6−19
  2. 서동애. (2001). 삼차원 인체 레이저 스캔 데이터를 이용한 남성 재킷 원형 설계방법에 관한 연구. 연세대학교 대 학원 박사학위 논문
  3. 윤승현, 현대은, 김명수. (2004). 3차원 인체치수측정과 형상 변형 기술. 패션정보와 기술, 1, 45−54
  4. 이정임, 주소령, Susan P. Ashdown. (2004). 노년 여성 체형 의 표준화된 3차원 측정 데이터 추출을 위한 기초 연구. 한국의류학회지, 28(2), 344−353
  5. 산업자원부 기술표준원. (2004). 인체표준용어집. 과천: 사이즈코리아, 기술표준원
  6. 산업자원부 기술표준원. (2005). 제5차 한국인 인체치수조사 자료. 과천: 사이즈코리아, 기술표준원
  7. Brooke-Wavell, K., Jones, P. R. M., & West, G. M. (1994). Reliability and repeatability of 3-D body scanner(LASS) measurements compared to anthropometry. Annals of Human Biology, 21(6), 571−577 https://doi.org/10.1080/03014469400003572
  8. Istook, C. L. & Hwang, S. (2001). 3D body scanning systems with application to the apparel industry. Journal of Fashion Marketing and Management, 5(2), 120−132 https://doi.org/10.1108/EUM0000000007283
  9. Lee, J. & Ashdown, S. P. (2005). Upper body surface change analysis using 3D body scanner. Journal of the Korean Society of Clothing and Textiles, 29(12), 1595−1607
  10. Mckinnon, L. & Istook, C. L. (2001). Comparative analysis of image twin system and the 3T6 body scanner. Journal of Textile and Apparel, Technology and Management, 1(2), 1−7
  11. Mckinnon, L. & Istook, C. L. (2002). Body scanning. Journal of Fashion Marketing and Management, 6(2), 103−121 https://doi.org/10.1108/13612020210429458
  12. Paquette, S., Brantley, J. D., Corner, B. D., Li, P., & Oliver, T. (2000). Automated extraction of anthropometric data from 3D images. Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Society, San Diego, USA, 6, 727−730
  13. Simmons, K. P. & Istook, C. L. (2003). Body measurement techniques. Journal of Fashion Marketing and Management, 7(3), 306−332 https://doi.org/10.1108/13612020310484852

Cited by

  1. Domestic Research Trends in IT Fashion vol.14, pp.4, 2012, https://doi.org/10.5805/KSCI.2012.14.4.614
  2. Development of a Body Size Measuring Process Utilizing 2D Images vol.33, pp.12, 2009, https://doi.org/10.5850/JKSCT.2009.33.12.1853