• Title/Summary/Keyword: Measurement Indicator

Search Result 496, Processing Time 0.024 seconds

A Study of the Recognition Regarding the Influence of Public Library Service to Quality of Life (공공도서관 서비스가 이용자의 삶의 질에 미치는 영향력에 대한 인식 조사 연구)

  • Noh, Younghee;Park, Yang-Ha
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.28 no.1
    • /
    • pp.45-77
    • /
    • 2017
  • Measurement of quality of life is a concept studied in the field of administration, economy and society. And It is a standard of measuring performance of government. Recently, in governments and global society, QoL (Quality of life) index is used to reflect overall development degree. National policy and service effectiveness measurement using QoL index is more persuasive when it is combined with 'Bottom-Up Spillover Theory'. This study applied "National Quality of Life Index", the object QoL index used by National Statistical Office to see if the library service is recognized to actually have influence on the quality of life, and furthermore, see the difference of quality of life improvement recognition by user and quality of life improvement degree recognized by the librarian. "Recognition regarding shortage of time" was the highest index, and "concentration of fine dust" was the lowest. Regarding the recognition difference between librarian and user, it showed signifiant difference in 13 index, while the recognition difference by gender showed difference in 5 index, difference by age was 23, difference by residence was 14, and difference by number of visits to library was 9.

Developing Measurement Model and Indicators for Entrepreneurial Ecosystem: Focusing on Regional E-Ecosystem Indicator via Delphi Analysis (창업생태계 측정모형과 지표개발: 델파이분석을 통한 지역창업생태계 측정지표 개발)

  • Lee, Woo jin;Oh, Hye Mi;Kim, Do Hyeon;Kim, Jong Sung;Kim, Ga Young
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.4
    • /
    • pp.1-15
    • /
    • 2020
  • As the entrepreneurial ecosystem turns out to be a leading factor in improving nation's entrepreneurship, many studies are underway in the country to develop the start-up ecosystem. Although the entrepreneurial ecosystem is receiving attention as an essential factor for the nation's economic growth as well as entrepreneurship due to its inter-relationship with start-ups, government agencies and investors, criticism of measurement indicators has been increasing due to the different institutional and political contexts of each country, including the various definition of start-up ecosystem. In this study, we develop indicators that are suitable for domestic conditions in Korea and that can measure the level of start-up ecosystems in each regional level. FGI and Delphi surveys by scholarly experts in each field of start-ups & entrepreneurship were conducted to verify how well existing indicators fit the domestic situation and to develop indicators that can measure the local entrepreneurial ecosystem in Korea through close examination. As a result, the local entrepreneurial ecosystem consisted of three to four sub-components and 38 sub-components, each consisting of seven indicators, including Policy, Investment, Culture, Market, Human Capital, Support and Knowledge. It is expected that this research will be used to diagnose local start-up ecosystems and to propose discriminatory policies that can complement regional strengths and weaknesses.

A Case Study on the Correlation between the Quantitative and the Qualitative Evaluation of IT Investment Performance (IT 투자성과의 정량적 평가와 정성적 평가의 상관관계에 관한 연구)

  • Lee, Jae-B.;Hong, Yu-Jin;Chang, Yun-Hi
    • Information Systems Review
    • /
    • v.9 no.2
    • /
    • pp.149-168
    • /
    • 2007
  • As the need for quantitative qualities of IT investment performance heightens, numerous research organizations are developing various measurement methods for the quantitative evaluation and its currency value conversion. Corporations utilizing these methods to evaluate IT investment performance are gradually increasing. However, working-level staff in the corporations that have introduced the quantitative evaluation can not assure if the evaluation sufficiently reflects the actual effect provided by IT since the results arising from the conversion of currency value can't be visibly confirmed. This study tries to identify whether the quantitative evaluation of IT investment performance can be explained in terms of the level of consumer satisfaction proven by the qualitative evaluation by analyzing the level of consumer satisfaction and quantitative evaluation of a case company and identifying the correlation between them. As the result of the case study, the following points have been concluded. Firstly, the currency value of IT effect correlates with the level of consumer satisfaction. Secondly, in order to come up with a rational currency value of IT effect, developing an indicator as well as managing data on currency conversion that will enable the internal system's efficiency to become more quantitative is essential. Thirdly, IT ROI is not appropriate to compare the performance between systems and is utilized as a measurement standard for each system's performance and efficiency. Lastly, quantitative evaluation is still inadequate in the evaluation of the system's strategic side, and consumer satisfaction can be utilized as a supplementary method.

Evaluation of Digital PCR as a Technique for Monitoring Acute Rejection in Kidney Transplantation

  • Lee, Hyeseon;Park, Young-Mi;We, Yu-Mee;Han, Duck Jong;Seo, Jung-Woo;Moon, Haena;Lee, Yu-Ho;Kim, Yang-Gyun;Moon, Ju-Young;Lee, Sang-Ho;Lee, Jong-Keuk
    • Genomics & Informatics
    • /
    • v.15 no.1
    • /
    • pp.2-10
    • /
    • 2017
  • Early detection and proper management of kidney rejection are crucial for the long-term health of a transplant recipient. Recipients are normally monitored by serum creatinine measurement and sometimes with graft biopsies. Donor-derived cell-free deoxyribonucleic acid (cfDNA) in the recipient's plasma and/or urine may be a better indicator of acute rejection. We evaluated digital PCR (dPCR) as a system for monitoring graft status using single nucleotide polymorphism (SNP)-based detection of donor DNA in plasma or urine. We compared the detection abilities of the QX200, RainDrop, and QuantStudio 3D dPCR systems. The QX200 was the most accurate and sensitive. Plasma and/or urine samples were isolated from 34 kidney recipients at multiple time points after transplantation, and analyzed by dPCR using the QX200. We found that donor DNA was almost undetectable in plasma DNA samples, whereas a high percentage of donor DNA was measured in urine DNA samples, indicating that urine is a good source of cfDNA for patient monitoring. We found that at least 24% of the highly polymorphic SNPs used to identify individuals could also identify donor cfDNA in transplant patient samples. Our results further showed that autosomal, sex-specific, and mitochondrial SNPs were suitable markers for identifying donor cfDNA. Finally, we found that donor-derived cfDNA measurement by dPCR was not sufficient to predict a patient's clinical condition. Our results indicate that donor-derived cfDNA is not an accurate predictor of kidney status in kidney transplant patients.

CHARACTERIZATION OF GEOTECHNICAL SITES BY MULTI-CHANNEL ANALSIS OF SURFACE WAVES(MCASW) (지표층의 탄성계수 측정을 위한 새로운 탄성파 방법)

  • 박춘병
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1995.10a
    • /
    • pp.15.2-22
    • /
    • 1995
  • Evaluating stiffness of near-surface materials has been one of the critically important tasks in many civil engineering works. It is the main goal of geotechnical characterization. The so-called deflection-response method evaluates the stiffness by measuring stress-strain behavior of the materials caused by static or dynamic load. This method, however, evaluates the overall stiffness and the stiffness variation with depth cannot be obtained. Furthermore, evaluation of a large-area geotechnical site by this method can be time-consuming, expensive, and damaging to many surface points of the site. Wave-propagation method, on the other hand, measures seismic velocities at different depths and stiffness profile (stiffness change with depth) can be obtained from the measured velocity data. The stiffness profile is often expressed by shear-wave (S-wave) velocity change with depth because S-wave velocity is proportional to the shear modulus. that is a direct indicator of stiffiiess. The crosshole and downhole method measures the seismic velocity by placing sources and receivers (geophones) at different depths in a borehole. Requirement of borehole installation makes this method also time-consuming, expensive, and damaging to the sites. Spectral-Analysis-of-Surface-Waves (SASW) method places both source and receivers at the surface, and records horizontally-propagating surface waves. Based upon the theory of surfacewave dispersion, the seismic velocities at different depths are calculated by analyzing the recorded surface-wave data. This method can be nondestructive to the sites. However, because only two receivers are used, the method requires multiple measurements with different field setups and, therefore, the method often becomes time-consuming and labor-intensive. Furthermore. the inclusion of noise wavefields cannot be handled properly, and this may cause the results by this method inaccurate. When multi-channel recording method is employed during the measurement of surface-waves, there are several benefits. First, usually single measurement is enough because multiple number (twelve or more) of receivers are used. Second, noise inclusion can be detected by coherency checking on the multi-channel data and handled properly so that it does not decrease the accuracy of the result. Third, various kinds of multi-channel processing techniques can be applied to f1lter unwanted noise wavefields and also to analyze the surface-wavefields more accurately and efficiently. In this way, the accuracy of the result by the method can be significantly improved. Fourth, the entire system of source, receivers, and recording-processing device can be tied into one unit, and the unit can be pulled by a small vehicle, making the survey speed very fast. In all these senses, multi-channel recording of surface waves is best suited for a routine method for geotechnical characterization in most of civil engineering works.

  • PDF

Development on the Urban Management Pollcy by the Types of Subway Station Areas: the Case of Seoul, Korea (역세권 유형별 특성에 의한 서울시 도시개발관리 방향 연구 : 서울시 지하철 역세권을 중심으로)

  • Kim, Ok-Yeon;Lee, Joo-Hyung
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.539-552
    • /
    • 2011
  • This research thesis measured potential housing development of 250 'subway station areas' around Seoul Metropolitain Region, with the use of added weighting and data of each indicator based on AHP. The analysis was conducted on the ranking of the development of 'subway station areas' on the basis of measurement results of potential housing development along with the analysis on characteristics of 'subway station areas' in daily life zone. Cluster analysis-oriented analytic measurement results suggested that 'subway station areas' in Seoul Metropolitain Region can be grouped into five clusters: Cluster 1 and Cluster 2 were populated with 'reservation areas' for outside and inside urban development, respectively scoring low all in housing development pressure and capacity. Cluster 3 was populated with 'development maintenance areas', scoring low in housing development pressure but high all in housing development capacity. Cluster 4 was populated with 'development facilitation areas', scored high all in housing development pressure and capacity. Cluster 5 was populated with 'development control areas' scoring high in housing development pressure but low in housing development capacity.

A Study of LiDAR's Detection Performance Degradation in Fog and Rain Climate (안개 및 강우 상황에서의 LiDAR 검지 성능 변화에 대한 연구)

  • Kim, Ji yoon;Park, Bum jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.2
    • /
    • pp.101-115
    • /
    • 2022
  • This study compared the performance of LiDAR in detecting objects in rough weather with that in clear weather. An experiment that reproduced rough weather divided the fog visibility into four stages from 200 m to 50 m and controlled the rainfall by dividing it into 20 mm/h and 50 mm/h. The number of points cloud and intensity were used as the performance indicators. The difference in performance was statistically investigated by a T-Test. The result of the study indicates that the performance of LiDAR decreased in the order in situations of 20 mm/h rainfall, fog visibility less than 200 m, 50 mm/h rainfall, fog visibility less than 150 m, fog visibility less than 100 m, and fog visibility less than 50 m. The decreased performance was greater when the measurement distance was greater and when the color was black rather than white. However, in the case of white, there was no difference in performance at a measurement distance of 10 m even at 50 m fog visibility, which is considered the worst situation in this experiment. This no difference in performance was also statistically significant. These performance verification results are expected to be utilized in the manufacture of road facilities in the future that improve the visibility of sensors.

A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

The Study on the Dilution Time of Radioactive Tracer in Estradiol Measurement (Estradiol 검사 시 방사성 추적자의 희석시간에 대한 고찰)

  • Lee, Hae Yeon;Seo, Han Kyung;Jang, Yi Sun;Kim, Hee Jeoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.44-48
    • /
    • 2017
  • Purpose Estradiol (E2) is a steroid hormone mainly produced in women and is a useful indicator for diagnosis of gynecological diseases, menstrual cycle, menopause, and precocious puberty. E2 measurement is performed by diluting the $^{125}I$ radioactive tracer and tracer buffer in the kit. However, It was not precisely specified when the period of tracer is available after activating. The purpose of this study was to determine the appropriate dilution time based on the measurement value with dilution time. Materials and Methods From December 2016 to February 2017, 60 E2 samples with concentrations ranging from 8 to 4577 pg/mL were divided into low, medium, and high concentrations. Dilution of the $^{125}I$ tracer was performed on a 230 RPM agitator for 30 minutes, 1 hour 30 minutes, and 2 hours 30 minutes, respectively. 24 hour dilution was gently shaken and refrigerated. To verify the difference and significance of the results according to the dilution time, a test of normality was performed using SPSS 18.0 and analyzed by Kruskal-Wallis test. The measured value according to the dilution time was compared with the interquartile range of the absolute error. Results The results of Kruskal-Wallis test were not significant (P>0.05). Measurement results are showed as interquartile range of absolute error. At low concentration, it is 0.052 between 1 hour 30 minutes and 2 hours 30 minutes, and 0.105 between 30 minutes and 1 hour 30 minutes. At medium concentration, 0.062 between 30 minutes and 1 hour 30 minutes, and 0.038 between 1 hour 30 minutes and 2 hours 30 minutes. At high concentration, it is 0.029 between 1 hour 30 minutes and 2 hours 30 minutes, and 0.06 between 2 hours 30 minutes and 24 hours. Conclusion There were no statistically significant differences. However, the change in the measured value is the smallest between 1 hour and 30 minutes to 2 hours and 30 minutes. Therefore, we recommend diluting time between 1 hour 30 minutes and 2 hours 30 minutes.

  • PDF