• Title/Summary/Keyword: Measured leakage quantity

Search Result 9, Processing Time 0.023 seconds

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

A Case Study on the Leakage in Concrete Face Rockfill Dam (콘크리트 표면차수벽형 석괴댐(CFRD)의 누수특성에 관한 사례연구)

  • 방돈석;신창건;이강용;안상로
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.197-202
    • /
    • 2003
  • The leakage quantity through concrete facing of Concrete Face Rockfill Dam(CFRD) is very small due to its low permeability of intact concrete. Even though the concrete facing is well designed and constructed, fine cracks can be generated due to effects of thermal and drying shrinkage. Therefore, it can be said that the leakage from the CFRD is subjected to not permeability of intact concrete but poor joints, cracks and foundation rocks. The Safety of a dam on leakage was evaluated based on the comparison between apparent permeability estimated and leakage quantity measured. The above method can be concluded to give a good direction for the evaluation of safety on CFRD in maintenance aspects as design and construction technology is improved with the accumulation of leakage data.

  • PDF

A Study on Long-Term Seepage Behaviour of Fill Dam by the Monitoring Data Analysis (계측자료 분석에 의한 필댐의 장기 침투거동 연구)

  • Chung, Kyujung;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.15-25
    • /
    • 2010
  • The main objective of this study was to offer informations about long-term seepage behavioral characteristics and to find a leakage safety management method for Juam Dam and Imha Dam, a central cored rockfill dams in Korea by the evaluating the automatically monitored leakage data. In the water leakage monitoring of fill dam, the generation of abnormal water leakage is difficult to directly detect due to the effect of outside factors such as the component of rainfall inherent in the observation value. Therefore, conventionally estimation methods of water leakage quantity were applied by multiple regression analysis considering reservoir water level, rainfall, etc.. However, the estimated error of rainfall component is relatively big in these method. This paper identifies the seepage characteristic of each dams which is not directly affected by rainfall through the hydrograph separation analysis and 3 dimensional analytical method, and thinks a leakage management method. It was noticed that two dams had site specific seepage behaviour features and were in stable state with the decreasing leakage quantity. It was also found that hydrograph separation method might be applicable to leakage safety management method.

Analysis of temperature monitoring data for leakage detection of earth dam (흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Seo, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Behavior of Pore Water Pressure of Agricultural Reservoir According to Raising Embankment (농업용 저수지 둑 높이기에 따른 제체의 공극수압 거동)

  • Lee, Dal-Won;Lee, Young-Hak
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, an experiment with large-scale model was performed according to raising embankment in order to investigate the cause of collapse by a change in water level of reservoir. Also, the settlement and pore water pressure by high water level and a rapid drawdown were compared and analyzed. After raising embankment for inclined core, there was no infiltration by leakage. For the vertical core, the pore water pressure showed a largely change by faster infiltration of pore water than in the inclined core. In a rapid drawdown, inclined core was remained stable but vertical core showed a largely change in pore water pressure. A settlement after a raising embankment showed a larger measure of settlement than before the raising embankment. The leakage quantity before a raising embankment and an inclined extension showed no leakage. Leakage in vertical extension was measured 160 $l$. From the result, a instrument system that can accurately estimate a change of pore water pressure shall be established for a rational maintenance and stabilization of raising embankment for agricultural reservoir.

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam (흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Suh, Baek-Soo;Kim, Joong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • Both multi-channel temperature monitoring and geophysical electric survey were performed together for an embankment to assess the leakage zone. Temperature variation according to space and time on the inner parts of engineering constructions (e.g.: dam and slope) can be basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation (e.g.: cracks and defects) could be generated by various factors. Seepage or leakage of water through the cracks or defects in old dams will directly cause temperature anomaly. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For that matter, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body. Geophysical data by electrical method are also added to help interpret data.

A Studyon the Movment of Ground Water of Banayweol Formation (반야월층(半夜月層)의 지하수운동(地下水運動)에 관(關)한 연구(硏究))

  • Kim, Yong Ki
    • Economic and Environmental Geology
    • /
    • v.9 no.4
    • /
    • pp.225-240
    • /
    • 1976
  • This study deals with the flow of bed rock ground water of Banyaweol Formation, which is presently cleared up as a laminar flow. The result obtained may be summarized as the following. 1) The Banyaweol Formation consists mainly of thin-bedded, green to blackish green shale, mudstone, and marl. The marl and mudstone alternatively occur with shale. The marl and mudstone form a aquifer of Banyaweol Formation. In this study, a group of aquifer is in convenience named as a aquifer zone. The aquifer occurs in lenticular form. The aquifer seems to be a type of artesian aquifer because it is covered with aquicludes, but it actually forms a unconfined aquifer because its piezometric surface stays under the lower aquiclude. The lowering of piezometric level is formed because of leakage of the ground water to the lower aquifer undersaturated. 2) The coefficient of permeability of Banyaweol Formation's ground water body (K) is derived by using Dupuit's equation as the following ${\log}K=\frac{CK^2-dK+f}{aK-b}\;\(M=1.365(2H-s)s\\M={\log}1.956s{\sqrt{H}}r\)$ here, $$a=\sum_{1}M_iG_i$$ $$b={\frac{1}{2}log{\sum_{i}}Q_i{^2}$$ $$c=2{\sum_{i}}M_i{^2}$$ $$d=loge{\sum_{i}}M_{i}Q_{i}+2{{\sum_{i}}N_{i}Q_{i}$$ $$f=loge{\sum_{i}}Q_i{^2}N_i$$ If the measured values substituted for the above equation, the coefficient of permeability of the aquifer is 4.1m/day. The coefficient of storge of the aquifer is $2.8{\times}10^{-4}$ if the measured values substituted for Theis's equation. Using the above constants, the filtration velocity of the aquifer is $2.1{\times}1O^{-1}m/day$and the daily flow quantity of the ground water is $847.38m^{3}/day$. 3) In order to understand the time necessary for a circulation of ground water body, the contents of tritum contained in the ground water are measured as 2.3 T.U. at the Korea Atomic Energy Research Institute. Before 1952, the average concentration of tritium per year in groundwater was reported as 10T. u., taking it as the standard, the groundwater of the present study 26.25 years old. Therofore, the groundwater of the Banyaweol Formation is judged as an relatively old groundwater. It is characteristic that the ground water of Banyawol Formation is laminar flow as well as unconfined aquifer and ground water flow of relatively long time. 4) The nature, means of flow, and circulation of Banyaweol Formation's ground water body make it possible set up this ground water body as a ground water system.

  • PDF

Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory (폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • This study was conducted to the improvement of solar light-based artificial light supply system and effect of lettuce cultivation. The artificial light supply system was consisted of units such as light source, power, system measurement and controller. The light source supply was composed of a solar transmitter and an LED lamp. The power supply consisted of an leakage breaker, SMPS, LED controller and relay. The solar transmitter was made of a quartz optical fiber with optimal light transmission. Artificial light used white lamp among LEDs. System measurement and control consisted of touch screen, Zigbee communication module and light quantity sensor. The results of test confirmed that the LED light is automatically activated when the intensity measured by the light intensity sensor is 200 μmolm-2s-1 or less. Moreover, the leaf length, root length, chlorophyll content and root fresh weight of optical fiber treatment was hight than LED lamp treatment. Therefore, it can be inferred that the energy-saving solar light collector device can be effective in the indoor lettuce production. However, the use of LED lamp is also recommended to assure the availability of sufficient sunlight in cloudy and rainy days.