• Title/Summary/Keyword: Maximum frequency value

Search Result 586, Processing Time 0.026 seconds

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF

A NEW FAMILY OF FREQUENCY HOPPING PATTERNS WITH GOOD HAMMING AUTOCORRELATION AND CROSSCORRELATION (우수한 해밍 자기상관성 및 타 상관성을 갖는 새로운 주파수 도약 패턴 군)

  • 노종선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1735-1741
    • /
    • 1993
  • New family of frequency hopping patterns with long period and good Hamming autocorrelation and Hamming crosscorrelation properties which can be used for frequency hopped multiple access communication systems is introduced. Period of frequency hopping patterns is qk-1, the alphabet size of frequency hopping patterns is q, and the size of family of frequency hopping patterns is q, where k is arbitrary integer and q is power of prime number. The maximum value of out-of-Phase Hamming autocorrelation function of any frequency hopping pattern and Hamming crosscorrelation function of any two frequency hopping patterns in the family is qk-1, which corresponds to optima1 Hamming correlation properties. And the average number of hits per q*q square in one frequency hopping pattern and its time shifted version or two frequency hopping patterns in the frequency hopped multiple access communication systems is less than 1.

  • PDF

Physiological Assessment of the Psychophysical Maximum Acceptable Weight of Load for Manual Materials Handling Tasks (인력물자취급시의 인체심리학적 최대허용중량의 생리학적 고찰)

  • Jeong, Seong-Hak;Kim, Hong-Gi
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 1999
  • The objective of this study was to investigate the metabolic energy consumption rate of the psychophysical Maximum Acceptable Weight of Loads (MAWLs) for different manual materials handling tasks. Lifting activities with four different lifting frequencies (2, 5, 8, 11 lifts/min) for a lifting range (from floor to 76cm height) were studied. The oxygen consumption rate and heart rate were measured or recorded while subjects were lifting their MAWLs. It was found that the relationship between MAWL and frequency can be described best by the exponential function with the R-sq value 0.9865 for this study. Psychophysical MAWL decreased from 22.38 to 7.48 kg, while the oxygen consumption rate with the MAWL increased from 717.8 to $1114.7m{\ell}-O_2/min$ as the frequency increased from 2 to 11 lifts/min. Heart rate also increased from 104.5 to 120.7 bpm. The ratio of oxygen consumption for the MAWL to the Physical Work Capacity (PWC) ranged from 28 to 43%. The MAWLs were greater than or equal to the Maximum Permissible Limits (MPLs) when the frequencies were higher than 8 lifts/min. It seems that the MAWLs by psychophysical approach when the frequencies were higher than 8 lifts/min tend to be overestimated from the viewpoint of the physiological criterion of the oxygen consumption rates. From these findings it is suggested that the NIOSH Guideline should not be directly applied to Korean without reasonable modifications.

  • PDF

A Basic Correlational Study of the Relationship between Maximum Muscle Power and EMG (최대 근력과 관련하여 EMG 상관관계에 관한 기초 연구)

  • Lee, Sung-bok;Kim, Dong-jun;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1815-1820
    • /
    • 2017
  • In this paper, a study was conducted to estimate the maximum muscle strength which is a standard for selecting exercise intensity in weight training. We designed a device that estimates the muscle fatigue from the EMG signal, expecting to show a correlation between peak muscle strength and fatigue. Curl - Dumbbell was performed using a 4 kg dumbbell and the frequency change of the EMG was observed. At this time, the designed device acquires the signal using the MCU and finally Matlab was used to confirm the change in the center frequency value. The results of 10 subjects were analyzed using SPSS regression analysis. The statistical results showed a correlation of $R^2$ 0.583 and Significant probability of 0.010, and the relation of Y = 8.144-2.097 (slope (MDF)) was obtained. In conclusion, if the wearable device is manufactured in the form of a wearable device and the user can recommend the exercise intensity, the system will be able to retry the more efficient exercise.

Optimum Design of the Laminated Composite Sandwich Plate Structure of Truss Core considering Vibration Characteristics (복합적층 트러스 코어형 샌드위치 판구조물의 진동특성을 고려한 최적설계)

  • Jung, Suok-Mo;Hong, Do-Kwan;Ahn, Chan-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.703-709
    • /
    • 2001
  • In this paper, we analyzed the laminated composite sandwich plate structure of truss core with changing values of the designing parameters. As a result, in designing parameters of that, the more height and thickness of the laminated composite plate's core, the more increase of natural frequency. In this type of structure, in the case of applying core of the laminated composite plate and antisymmetric stacking, natural frequency has high value and we calculated the optimum angle-ply making natural frequency maximum. Natural frequency of CFRP is higher than that of GFRP. Both are materials of the laminated composite plate. The mode shapes are various along with the angle-ply of the laminated composite plate.

  • PDF

Calcualtion and Comparison of Drought Indices on Major Weatehr Stations in Korea (우리 나라 주요 지점에 대한 가뭄지수의 산정과 비교)

  • 김상민
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.5
    • /
    • pp.43-52
    • /
    • 1999
  • In an effort to identify quantitatively historical drought conditions, and to evaluate their temporal and spatial variability , two commonly used drougth indices, the standardized precipitation index, SPI by Mckee and the Palmer drought severity index. PDSI were calculated from 54 meteorological stations, SPI was evaluated for different time scales, 3 to 48 months. As the compjtational spans for SPI increase from 3 to 48 months the frequency and intensity of drought decrease, but the duration of drought increase. When monthly and ten-day PDSIs were compared, the frequency and duratin of drought were almost equal and the intensity of drought differ slightly. The three month SPI has the advatage to detect the drought resulting from short-term shortage of rainfall, while PDSI had the advantage to detect the state of drought resulting from cumulated shortage of rainfall. The period-frequency spectrum analyses at Kangnung statino showed that the maximum value of relative frequency was 24.4% when the period was 5.2months, and the 6month SPI has most similar trends to PDSI.

  • PDF

Effect of B-Bi-Zn Addition on the Permeabilities of Hexagonal-ferrite (B-Bi-Zn 첨가가 hexagonal-ferrite 특성에 미치는 영향)

  • 정승우;백승철;김성수;최우성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.204-207
    • /
    • 2000
  • In this paper, we have studied the effect of doped with B-Bi-Zn on properties (microstructure, density, shrinkage, permeability as a function of frequency, etc.) of hexagonal-ferrite for high frequency chip-inductor material about several GHz. The permeability were analyzed by impedance analyzer(100 kHz~40 MHz) and network analyzer(30 MHz~3 GHZ). As a result of the characteristics, the B-Bi-Zn glass ceramic was used to lower the sintering temperature for additive as a function of frequency from 100 kHz to 1.8 GHz showed constant tends. The maximum imaginary value of complex permeability was observed near the resonance frequency of 2 GHz.

  • PDF

Characteristics of Diurnal Variation of the Atmospheric Pollutants Concentration in High-Ozone Episode day in Daegu (대구시 고농도 오존 사례일인 경우 대기 오염물질 농도의 일변화 특성)

  • 손임영;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1253-1259
    • /
    • 2002
  • This study analyzes the surface ozone, NO and $NO_2$ concentration data from 1997 to 1999 in Daegu. It investigates effect on precursor during high-ozone episode days. The high-ozone episode is defined when a daily maximum ozone concentration is higher than 100 ppb(ambient air quality standard of Korea) in at least one station among six air quality monitoring stations. The frequency of episodes is 13 days(33 hours). The frequency is the highest in May and September, and the area with the highest frequency is Nowondong and Manchondong. The average value of daily maximum ozone concentration with high ozone episode is 81.6 ppb, and that of 8-hour average ozone concentration is 58.6 ppb. It means that ozone pollution is continuous and wide-ranging in Daegu. The daily variation of NO, $NO_2$ and $O_3$ in high-ozone episodes are inversely proportional one another. Nowondong an industrial area, is affected by pollutants that are emitted from the primary sources, while Manchondong a residential area, is affected by the advection of $O_3$ or by the primary pollutants like VOCs.

Microstructural, Dielectric and Electrical Properties of(Pb,La,Ce)TiO3 Ceramics for High Frequency Ceramic Resonator as a function of MnO2 Addition

  • Yoo, Ju-Hyung;Oh, Dong-On;Park, Chang-Yub;Kim, Ji-Hong;Lee, Sung-Ill;Ryu, Sung-Lim
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.25-28
    • /
    • 2002
  • In this study, microstructural, dielectric and electrical properties of (Pb$\sub$0.83/) (La$\sub$0.2/Ce$\sub$0.8/)$\sub$0.08/TiO$_3$(PCT) ceramics as a function of MnO$_2$ addition and electrode size variation were investigated for 30 MHz high frequency ceramic resonator application. Grain size was gradually increased according to the increase of MnO$_2$ addition amount. Moreover, the density showed a constant value with increasing MnO$_2$ addition amount. Dielectric constant was decreased with increasing MnO$_2$ addition amount. Curie temperature of all the composition ceramics was nearly constant around 330$^{\circ}C$. The maximum D.R.of 50.5 dB and maximum Q$\sub$mt3/ of 1842 in the 3$\^$rd/ overtone vibration mode were appeared at the composition of 0.3wt% MnO$_2$, respectively.

A Cepstral Analysis of Breathy Voice with Vocal Fold Paralysis (성대마비로 인한 기식 음성에 대한 Cepstral 분석)

  • Kang, Young-Ae;Seong, Cheol-Jae
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.89-94
    • /
    • 2012
  • The aim of this study is to investigate the usefulness of the parameter CPP (cepstral peak prominence) and LTAS (long term average spectrum) band energy for an analysis of breathy voice with vocal fold paralysis. Thirty-four female subjects who have vocal paralysis after thyroidectomy participated in this study. According to the perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 13). Maximum sustained phonation task was measured for acoustic analysis. CPP-related (i.e. mean F0, mean CPP, and mean CPPs) and LTAS-related (i.e. minimum, maximum, and mean) parameters were used. Independent samples t-test was conducted. Regarding CPP, there are significant differences in mean CPP and mean CPPs between groups. The values of mean CPP and CPPs in the non-breathy voice group are higher than those in the breathy voice group. The CPP could be regarded as the useful parameter for breathy voice analysis in the clinic. When it comes to LTAS, energy from 0 to 2 kHz are significantly different between groups. The minimum value of non-breathy group is lower than that of breathy group, whereas the maximum value of non-breathy group is higher. The frequency band below 2 kHz seems to be related to breathy voice.