• Title/Summary/Keyword: Masonry structure

Search Result 199, Processing Time 0.023 seconds

Structural Characteristics Evaluation Considering Construction Circumstances of Cheomseongdae (첨성대의 축조현황을 고려한 구조적 특성평가)

  • Kim, Ho-Soo;Kim, Jung-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.3
    • /
    • pp.69-76
    • /
    • 2015
  • Cheomseongdae is the masonry stone structure with the cultural and historical values. But, this structure has the various damages such as cracks, gaps, slope variations and ground subsidence. So, the interests for the safety security in the structural parts have been increased. Therefore, this study performs the structural modelling which considers the several damage cases, and then evaluates the structural behavior characteristics through the discrete element analysis. Especially, this study checks the swelling and displacement gap of the whole structure and the separation between the neighboring members.

Application of shape memory alloy prestressing devices on an ancient aqueduct

  • Chrysostomou, Christis Z.;Stassis, Andreas;Demetriourder, Themos;Hamdaoui, Karim
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.261-278
    • /
    • 2008
  • The results of the application of shape memory alloy (SMA) prestressing devices on an aqueduct are presented in this paper. The aqueduct was built in 1747 to provide water to the city of Larnaca and to its port. Because of its importance to the cultural heritage of Cyprus, the aqueduct has been selected as one of the case-study monuments in the project Wide-Range Non-Intrusive devices toward Conservation of Historical Monuments in the Mediterranean Area (WIND-CHIME). The Department of Antiquities of Cyprus, acting in a pioneering way, have given their permission to apply the devices in order to investigate their effectiveness in providing protection to the monument against probable catastrophic effects of earthquake excitation. The dynamic characteristics of the structure were determined in two separate occasions and computational models were developed that matched very closely the dynamic characteristics of the structure. In this paper the experimental setup and the measured changes in the dynamic characteristics of the monument after the application of the SMA devices are described.

Experimental and numerical analysis of RC structure with two leaf cavity wall subjected to shake table

  • Onat, Onur;Lourenco, Paulo B.;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.55 no.5
    • /
    • pp.1037-1053
    • /
    • 2015
  • This paper presents finite element (FE) based pushover analysis of a reinforced concrete structure with a two-leaf cavity wall (TLCW) to estimate the performance level of this structure. In addition to this, an unreinforced masonry (URM) model was selected for comparison. Simulations and analyses of these structures were performed using the DIANA FE program. The mentioned structures were selected as two storeys and two bays. The dimensions of the structures were scaled 1:1.5 according to the Cauchy Froude similitude law. A shake table experiment was implemented on the reinforced concrete structure with the two-leaf cavity wall (TLCW) at the National Civil Engineering Laboratory (LNEC) in Lisbon, Portugal. The model that simulates URM was not experimentally studied. This structure was modelled in the same manner as the TLCW. The purpose of this virtual model is to compare the respective performances. Two nonlinear analyses were performed and compared with the experimental test results. These analyses were carried out in two phases. The research addresses first the analysis of a structure with only reinforced concrete elements, and secondly the analysis of the same structure with reinforced concrete elements and infill walls. Both researches consider static loading and pushover analysis. The experimental pushover curve was plotted by the envelope of the experimental curve obtained on the basis of the shake table records. Crack patterns, failure modes and performance curves were plotted for both models. Finally, results were evaluated on the basis of the current regulation ASCE/SEI 41-06.

A Study on the Formation and Character of Cheong Ju Presbyterian Missionary Architecture from 1900 to 1945 (미국(美國) 북장로회(北長老會) 청주선교부(淸州宣敎部) 건축(建築)의 형성(形成)과 특성(特性))

  • Dho, SunBoong;Han, KyuYoung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.3 no.1
    • /
    • pp.25-40
    • /
    • 2001
  • In this study, I investigate the formation process of the American presbyterian missionary architecture in Cheong Ju area from 1900 to 1945, which we may think 'the part of Korean modern architecture'. I have examined and analyzed the 18 buildings for the sake of the interpretation with the words of formation process and characteristics . And I can put my idea in order as follows. Firstly, the formation process is 1) buy and modify a Korean style (thatch or tile roofed) building for their need and use it as a gate quaters or house, church, hospital, school, book store, 2) build a Korean style (tile roofed) building and use it-house, hospital, school, 3) build a Western style (timber structured and zinc roofed) building and use it- church, 4) build a Western style (masonry structured and tile or zinc roofed) building and use ithouse, church, school and hospital. Secondly, the characteristics is 1) In the Korean style building, the missionaries change into the function to match with their purpose. they modify the Korean style timber structure by influx of building material-brick, glass, carpet etc. they occupy into the Korean existing residential area. 2) In the Western style building, the missionaries build the house correspond with their living pattern. they build the church with the eclectic of Western and Korean timber frame. and also build the house and hospital with the eclectic of Western and Korean masonry structure. their building located in the isolate hill separated from the existing Korean residential area.

  • PDF

Experimental Study on Steel Truss Structure for Safety Lintel in Masonry Construction -Focusing on Door Frame Top Lintel at Typical Floor Apartment- (조적공사 인방보용 강재트러스 구조물에 관한 실험적 연구 - 아파트 기준층 문틀 상단 인방재를 중심으로 -)

  • Kim, Young-Chun;Yoo, Hyun-Dong;Choi, Woo-Jong;Jeong, Sang-Moo;Kang, Myung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.29-35
    • /
    • 2013
  • The research is to verify by experiments whether the steel truss structure is able to withstand the load of cement bricks of upper part of a door for the safe use of lightweight steel truss structure instead of concrete lintel which is to be installed at upper part of door frame in building cement bricks for apartment construction. The steel truss is designed in order not to disturb bricks-building and the shape of structure was verified by bending test. According to experiments result, camber was applied to steel structure that enabled construction work to be improved and was proved effective for the prevention of accidents by cement bricks-building load test.

Structural Characteristics Analysis of Stone Contact Surface according to Surface Roughness and Filling Material of Stone Pagoda Structure (석탑구조물의 표면거칠기 및 충전재에 따른 석재접촉면의 구조특성 분석)

  • Kim, Ho-Soo;Kim, Dong-Kwan;Lee, Seung-Hee;Kim, Derk-Moon;Jo, Sang-Sun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.19-27
    • /
    • 2018
  • The stone pagoda structure is treated as a discontinuous masonry structure, and the contact surface characteristics between stones is a very important factor in the discontinuum behavior analysis. So, it is necessary to find out material and structural characteristics of stone contact surface to perform the structural analysis for safety evaluation. Accordingly, it is important to analyze the material properties of stone surface and secure the structural characteristics through various contact surface states. Therefore, in this study, various test specimens applying the filler between the surface roughness and the stone in the contact surface treatment technique of the stone pagoda were manufactured, and compression test and shear test were carried out. Also, we analyzed the material and structural characteristics of the stone contact surface through the comparison of experimental results.

An Evaluation Study On Response Modification Factor of Unreinforced Mansonry Structure (비보강 조적조 건축물의 반응수정계수 설정에 관한 연구)

  • Kwon, Ki-Hyuk;Lee, Yong-Hwan;Yi, Waon-Ho;Lee, Jung-Han;Kang, Dae-Eon
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.33-36
    • /
    • 2007
  • This study shows the basic data for setting up a response modification factor of unreinforcement masonry structure by considering and analyzing the experiment results of the domestic walls. If the result of this study compare with the value R of KBC-2005, 1.5, the average value, 1.2, is the low value. However, the maximum value, 2.57, is more than 70% bigger than the standard value. The standard value of overstrength factor, 2.5 is judged to have relatively bigger value than this study.

  • PDF

Ambient vibration tests on a 19 - story asymmetric steel building

  • Shakib, H.;Parsaeifard, N.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Ambient vibration tests were carried out to evaluate the dynamic properties of an asymmetric steel building with semi-rigid connections. The test case has many non-structural elements, constructed in the city of Tehran (Iran). The tests were conducted to obtain natural frequencies, mode shapes and damping ratio of the structure and then Fourier transform were used to analyze the velocity records obtained from the tests. The first and second natural periods of the building were obtained as 1.37 s and 1.28 s through the test and damping ratio for the first mode was calculated as 0.047. However, Natural periods obtained from finite element model have higher values from those gained from ambient vibration. Then the model was calibrated by modeling of the in-fill masonry panels at their exact locations and considering the boundary conditions by modeling two blocks near the block No. 3, but the differences were existed. These differences may be due to some hidden stiffness of nonstructural elements in the low range of elastic behavior, showing the structure stiffer than it is in reality.

Effect of brick infill panel on the seismic safety of reinforced concrete frames under progressive collapse

  • Tavakoli, Hamidreza;Akbarpoor, Soodeh
    • Computers and Concrete
    • /
    • v.13 no.6
    • /
    • pp.749-764
    • /
    • 2014
  • Structural safety has always been a key preoccupation for engineers responsible for the design of civil engineering projects. One of the mechanisms of structural failure, which has gathered increasing attention over the past few decades, is referred to as 'progressive collapse' which happens when one or several structural members suddenly fail, whatever the cause (accident, attack, seismic loading(.Any weakness in design or construction of structural elements can induce the progressive collapse in structures, during seismic loading. Masonry infill panels have significant influence on structure response against the lateral load. Therefore in this paper, seismic performance and shear strength of R.C frames with brick infill panel under various lateral loading patterns are investigated. This evaluation is performed by nonlinear static analysis. The results provided important information for additional design guidance on seismic safety of RC frames with brick infill panel under progressive collapse.

A Study on the Planning Characteristics of Passive House by the Building Structural Types in Foreign Cases (해외 패시브하우스의 건축구조유형별 계획특성 연구)

  • Yang, Jung-Pil
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.15-20
    • /
    • 2013
  • The purpose of this study is to analyze the planning characteristics of passive house by the building structural types in foreign cases. The interests and demands about passive house have been increased, and various building structural types and design methods have been attempted for passive house in Korea. But domestic research results and development experiences about passive house were lack. The results of this study are as follows; First, in terms of energy performance, insulation performance, airtightness, there are not significant differences at the 95% confidence level by the structural types of passive house. Second, in terms of the types of insulation materials, there are significant differences at the 95% confidence level by the structural types of passive house. Third, in principle there is no need of traditional heating facility in passive houses, but in practice traditional heating facilities are used additionally in about half of survey cases for the comfort of occupants.