• Title/Summary/Keyword: Mandibular function

Search Result 387, Processing Time 0.025 seconds

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

TREATMENT OF IMPACTED CANINE : CASE REPORTS (매복견치의 치료: 증례보고)

  • Ahn, Byung-Duk;Kim, Young-Jae;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.151-158
    • /
    • 2008
  • Upper and lower cuspids are very important teeth in point of function as well as esthetic. However, failure of eruption of the canine sometimes happens and is frequently encountered clinical problems. Upper cuspids are more frequently impacted as compared with lower cuspis and palatally impaction is more frequent event than labially impaction. Impaction of the mandibular canine is unusual event, especially crossing the midline (transmigration) is very rare. Because of, in most cases, there is no signs and symptoms, impacted teeth can be detected by periodic radiograph examination. The etiology of impaction is unclear and multifactorial. The treatment of impacted canine is influenced by presence of obstacles, location and direction of impaction, space for alignment and development of root. There are several treatment options; (1) Surgical removal and/or observation, (2) Window opening and orthodontic traction, (3) Autotransplantation. The first patient (impaction of upper right cuspid) is treated with window opening and orthodontic traction. The second patient (bilaterally impaction of lower cuspids) is treated with autotransplantation, because of transmigration.

  • PDF

AN EXPERIMENTAL STUDY ON THE TISSUE RESPONSE OF THE TEMPOROMANDIBULAR JOINT IN UNILATERAL MANDIBULAR EDENTULISM (하악편측치아의 결손에 따른 악관절의 조직반응에 대한 연구)

  • Paik, Hyee-Seon;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.285-294
    • /
    • 1991
  • The human temporomandibular joint as a ginglymoarthrodial one has much in common with the other synovial joints of the body, but it does possess an unique charachteristic in that it must accomodate the various occlusal relations of dentition during an end point of closure. For that reason, the movement of the condyle in the temporomandibular joint is susceptible to influences from the nature of occlusion. Undue loading to the temporomandibular joint can be applied on the occasion of premature contacts in centric relation, balancing side interferences, change of occlusal surfaces due to excessive attrition, loss of tooth. Such occlusal disharmonies in association with the systemic and emotional factors may give rise to the temporomandibular disorder. On the other hand, the changes of occlusal patterns in the growing body can also have an effect on the growth of the temporomandibular joint through the alterations of functional stresses. The purpose of this study was to observe histopathologic response of the temporomandibular joint in unilateral chewing on one side exclusively for 10 months. Three dogs showing normal masticatory function were chosen. One dog aged about 12 months was for control, two dogs for experimental specimens were about 12 and 18 months old respectively. For chewing on the left side only, unilateral lower right premolar and molar were extracted in two experimental specimens. And then three dogs were sacrificed 10 months later. Frontal histologic sectioning of joints were done for the observation of the effects of one-side chewing. 24 specimens from three dogs were obtained and fixed in 10% formalin and routinly processed with H-E staining for histologic examination. The light microscopic findings were interpretated as follows: 1. Experimental specimen 1 aged about 22 months: In comparison with control and right non-chewing side, the proliferative and hypertrophic zone were increased at the mesial and lateral part of left chewing side condyle. There was no change of the articular tissue of temporal bone. 2. Experimental specimen 2 aged about 28 months: The articular tissues of adult joint were observed. The differences between the chewing and non-chewing side were not seen in the articular tissues of condyle and temporal bone.

  • PDF

A RADIOGRAPHIC STUDY ON THE MANDIBULAR CONDYLE POSITION IN KOREAN MALOCCLUSION (부정교합자의 하악과두 위치에 관한 방사선적 연구)

  • Kang, Jeoung-Hee;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.109-121
    • /
    • 1992
  • Temporomandibular joint is a major structure to play an important role in the function & stability of the occlusion as well as the stomatognathic system. Therefore, the TMJ is the structure that requires the complete analysis for diagnosing and planning treatment of pathologic changes by TMJ dysfunction and malocclusion. So, in this study, to evaluate TMJ situation in Korean malocclusion, based on the previous accomplishments, students of the dental college of Won-Kwang Univ. are surveyed and selected in terms of Angle's classification of malocclusion, whose TMJ radiographs were taken in the centric occlusion and centric relation. In each maiocclusion groups, the mean and standard deviation of anterior, posterior and superior joint space of the right, left and both side in CO & CR are evaluated and also those of the fossa height and the articular eminence angle of the right, left and both sides are evaluated. The obtained results were as follows: 1. In the correlation coefficient between the malocclusion groups, no other items except the posterior joint space of the right side in CR between in class I and class III are significant. 2. In the correlation coefficient between the right and left side, the each joint space in class I malocclusion group and class II malocclusion group are significant. 3. In the change of each joint space during the transmit from CO to CR, there is a tendency of increasing anterior joint space and decreasing posterior, superior joint spaces in class I, II malocclusion and increasing superior joint space and decreasing anterior, posterior joint space in class III malocclusion, which is significant in the correlation coefficient, but not significant in the T-test. 4. In each malocclusion group, the correlation coefficient between the posterior joint space and the superior joint space in C.R is highly significant. 5. The fossa height of class II malocclusion group is lesser than that of class I or class III, which is not significant in T-test. 6. In the correlation coefficient between Rt. and Lt. side in the fossa height, it is not significant in class I and class III group, but significant in class II malocclusion group. 7. The articular eminence angle of class II malocclusion group is larger then that of class I or class III groups, which is fairly significant. 8. In the correlation coefficient between Rt. and Lt. side in the articular eminence angle, it is significant in each malocclusion group.

  • PDF

FLEXION EFFECTS OF HEAT TREATMENT AND POST-SOLDRING OF CERAMO-METAL FIXED PARTIAL DENTURE FRAMEWORKS USING HOLOGRAPHIC INTERFEROMETRY (Holographic Interferometry를 이용한 하악 구치부 도재소부 전장관용 금속 구조물의 굴곡성향에 대한 연구)

  • Choi, Jin-Woong;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.869-902
    • /
    • 1996
  • Flexion of a metal/ceramic fixed partial denture(EPD) frameworks under function can cause fracture of porcelain or deterioration of the cement seal. This study evaluated the flexion characteristics of three-unit mandibular FPD frameworks, repacing the second pre-molar under compressive load(200g, 400g). Testing was accompished with real-time holographic interferometry, using 6 porcelain fused-to metal frameworks. Tested alloys were non-precious alloy(Heracles, Holland), semi-precious alloy(Degudent U, Germany) and precious alloy(Degudent H, Germany). Changes of the fringe patterns according to the heat treatment(porcelain firing cycle), various loads(200g, 400g), occlusal forms(occlusal porcelain veneering, facial porcelain veneering), various alloys and post-soldering units were compared. Dental study model(Nissan dental products, Inc. D51DP-500A, Japan) and six 3-unit metal/ceramic fixed partial denture frameworks were used as experimental materials. 36 holograms were taken on fixed dental study model by using the 10mW He-Ne laser and real-time holographic interferometry. On the basis of this study, the following conclusions can be drawn : 1. In the frameworks for facial porcelain veneering, the semi-precious alloy framework was least deformed and precious alloy framework, non-precious alloy framework orderly before heat treatment, and the deformation was not shown great difference among three alloys after heat treatment and post-soldering. 2. In the frameworks for occlusal porcelain veneering, the precious alloy framework was greatest deformed and the deformation was not difference between semi-precious alloy framework and non-precious alloy framework before, after heat treatment, and the deformation was not shown great difference among three alloys after post soldering. 3. In the non-precious alloy frameworks for facial porcelain veneering and occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and conversely increased after post-soldering. 4. In the semi-precious alloy framework for facial porcelain veneering, the deformation was not detectable after heat treatment and increased after post-solder. And in the frame-work for occlusal porcelain veneering, the deformation was slightly decreased after heat treatment and increased after post-soldering. 5. In the precious alloy framework for facial porcelain veneering, the deformation was greatly decreased after heat treatment and increased after post-soldering, And in the framework for occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and decreased after post-soldering.

  • PDF

Dimensional change of the healed periosteum on surgically created defects

  • Cho, Eun-Hee;Park, Jung-Chul;Cha, Jae-Kook;Kim, Yong-Tae;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Purpose: The final goal of regenerative periodontal therapy is to restore the structure and function of the periodontium destroyed or lost due to periodontitis. However, the role of periosteum in periodontal regeneration was relatively neglected while bone repair in the skeleton occurs as a result of a significant contribution from the periosteum. The aim of this study is to understand the histological characteristics of periosteum and compare the native periosteum with the repaired periosteum after elevating flap or after surgical intervention with flap elevation. Methods: Buccal and lingual mucoperiosteal flaps were reflected to surgically create critical-size, "box-type" (4 mm width, 5 mm depth), one-wall, intrabony defects at the distal aspect of the 2nd and the mesial aspect of the 4th mandibular premolars in the right and left jaw quadrants. Animals were sacrificed after 24 weeks. Results: The results from this study are as follows: 1) thickness of periosteum showed difference as follows (P<0.05): control group ($0.45{\pm}0.22$ mm)> flap-elevation group ($0.36{\pm}0.07$ mm)> defect formation group ($0.26{\pm}0.03$ mm), 2) thickness of gingival tissue showed difference as follows (P<0.05): defect formation group ($3.15{\pm}0.40$ mm)> flap-elevation group ($2.02{\pm}0.25$ mm) > control group ($1.88{\pm}0.27$ mm), 3) higher cellular activity was observed in defect formation group and flap-elevation groups than control group, 4) the number of blood vessles was higher in defect formation group than control group. Conclusions: In conclusion, prolonged operation with increased surgical trauma seems to decrease the thickness of repaired periosteum and increase the thickness of gingiva. More blood vessles and high cellular activity were observed in defect formation group.

Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis (임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Kim, Jang-Eung;Choi, Yu-Sung;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.205-220
    • /
    • 2010
  • Purpose : To analyze the effect of implant designs on insertion torque and stress by performing a comparative study on von Mises stress, torque and normal force through a three-dimensional finite element analysis. Materials and methods : Models of the screw type implant were used to model the implant as a form placed in the mandibular premolar region applying a three-dimensional finite element method. Screw type implant designs were classified into 4 types of parallel ones and 7 types of tapered ones. Other factors were simulated to represent clinical environment. Results : In parallel implant designs, higher and wider threads resulted in higher insertion torques and higher stress distributions. In tapered implant designs, changes in the taper led to remarkable differences in the insertion torques. It was difficult to determine a certain tendency of stress distribution around the implants since the stress level was too high around them. In tapered implant designs, smaller implants demonstrated lower insertion torques than the original type and were relatively less dependent on the degree of taper. Tapered implants showed higher insertion torques and higher stress distributions than parallel implants. Conclusion : According to this study, although the tapered implant demonstrated a higher insertion torque than the parallel implant, stress tended to be concentrated in the entire fixture of the tapered implant due to the inefficient stress distribution.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.

The Effects of Screw Retained Prosthesis Misfit & Cantilever on Stress Distribution in Bone Around the Implant (나사유지형 임플란트 고정성 보철물의 적합도와 캔틸레버가 지지골조직의 응력분산에 미치는 영향)

  • Lee, Jae-In;Kim, Tae-Young;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.224-235
    • /
    • 2013
  • A passively fitting prosthesis is an essential prerequisite to attain long-lasting success and maintenance of osseointegration. However, true "passive fit" can not be achieved with the present implant-supported prosthesis fabrication protocol. Many clinical situations are suitably treated with cantilevered implant-supported fixed restorations. The purpose of this study was to compare the stress distribution pattern and magnitude in supporting tissues around ITI implants with cantilevered, implant-supported, screw-retained fixed prosthesis according to the fitness of superstructures. Photoelastic model was made with PL-2 resin (Measurements, Raleigh, USA) and three ITI implants (${\phi}4.1{\times}10mm$) were placed in the mandibular posterior edentulous area distal to the canine. Anterior and posterior extended 4-unit cantilevered FPDs were made with different misfit in the superstructures. 4 types of prosthesis were made by placing a $100{\mu}m$ gap between the abutment and the crown on the second premolar and/or the first molar. Photoelastic stress analysis were carried out to measure the fringe order around the implant supporting structure under simulated loading conditions (30 lb).

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.